These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. Use of cyanoacrylate to prevent cerebrospinal fluid fistulas after cranial surgery. Asan Z; Kilitci A Br J Neurosurg; 2018 Oct; 32(5):544-547. PubMed ID: 30067116 [TBL] [Abstract][Full Text] [Related]
25. The use of dehydrated amniotic membrane allograft for augmentation of dural closure in craniotomies and endoscopic endonasal transphenoidal surgeries. Eichberg DG; Ali SC; Buttrick SS; Komotar RJ Br J Neurosurg; 2018 Oct; 32(5):516-520. PubMed ID: 29989435 [TBL] [Abstract][Full Text] [Related]
26. How I do it: shoelace watertight dural closure in extended transsphenoidal surgery. Takeuchi K; Nagatani T; Wakabayashi T Acta Neurochir (Wien); 2015 Dec; 157(12):2089-92. PubMed ID: 26477503 [TBL] [Abstract][Full Text] [Related]
27. Collagen-bound fibrin sealant (TachoSil®) for dural closure in cranial surgery: single-centre comparative cohort study and systematic review of the literature. Carretta A; Epskamp M; Ledermann L; Staartjes VE; Neidert MC; Regli L; Stienen MN Neurosurg Rev; 2022 Dec; 45(6):3779-3788. PubMed ID: 36322203 [TBL] [Abstract][Full Text] [Related]
28. CSF-Related Complications After Intradural Spinal Tumor Surgery: Utility of an Autologous Fat Graft. Arnautovic KI; Kovacevic M Med Arch; 2016 Dec; 70(6):460-465. PubMed ID: 28210022 [TBL] [Abstract][Full Text] [Related]
29. Polyethylene glycol (PEG) hydrogel dural sealant and collagen dural graft matrix in transsphenoidal pituitary surgery for prevention of postoperative cerebrospinal fluid leaks. Burkett CJ; Patel S; Tabor MH; Padhya T; Vale FL J Clin Neurosci; 2011 Nov; 18(11):1513-7. PubMed ID: 21868232 [TBL] [Abstract][Full Text] [Related]
30. The use of a reconstituted collagen foil dura mater substitute in paediatric neurosurgical procedures--experience in 47 patients. Pettorini BL; Tamburrini G; Massimi L; Paternoster G; Caldarelli M; Di Rocco C Br J Neurosurg; 2010 Feb; 24(1):51-4. PubMed ID: 20158353 [TBL] [Abstract][Full Text] [Related]
31. Cerebrospinal fluid leaks following spinal or posterior fossa surgery: use of fat grafts for prevention and repair. Black P Neurosurg Focus; 2000; 9(1):e4. PubMed ID: 16865811 [TBL] [Abstract][Full Text] [Related]
32. Cerebrospinal fluid leaks following spinal surgery: use of fat grafts for prevention and repair. Technical note. Black P J Neurosurg; 2002 Mar; 96(2 Suppl):250-2. PubMed ID: 12450290 [TBL] [Abstract][Full Text] [Related]
33. Cerebrospinal fluid leak after microsurgical surgery in vestibular schwannomas via retrosigmoidal craniotomy. Arlt F; Trantakis C; Krupp W; Renner C; Winkler D; Strauss G; Meixensberger J Neurol Res; 2011 Nov; 33(9):947-52. PubMed ID: 22080996 [TBL] [Abstract][Full Text] [Related]
34. Incidence, Characteristics, and Outcomes of Pseudomeningocele and Cerebrospinal Fluid Fistula after Posterior Fossa Surgery. Sastry RA; Walek K; Leary OP; Rex N; Shaaya EA; Poggi JA; Cielo D World Neurosurg; 2022 Aug; 164():e1094-e1102. PubMed ID: 35640831 [TBL] [Abstract][Full Text] [Related]
35. Results of TachoSil® associated with fibrin glue as dural sealant in a series of patients with spinal intradural tumors surgery. Technical note with a review of the literature. Montano N; Pignotti F; Auricchio AM; Fernandez E; Olivi A; Papacci F J Clin Neurosci; 2019 Mar; 61():88-92. PubMed ID: 30414810 [TBL] [Abstract][Full Text] [Related]
36. Efficacy and safety of non-suture dural closure using a novel dural substitute consisting of polyglycolic acid felt and fibrin glue to prevent cerebrospinal fluid leakage-A non-controlled, open-label, multicenter clinical trial. Terasaka S; Taoka T; Kuroda S; Mikuni N; Nishi T; Nakase H; Fujii Y; Hayashi Y; Murata JI; Kikuta KI; Kuroiwa T; Shimokawa S; Houkin K J Mater Sci Mater Med; 2017 May; 28(5):69. PubMed ID: 28357687 [TBL] [Abstract][Full Text] [Related]
37. Wound complications associated with the use of bovine serum albumin-glutaraldehyde surgical adhesive in pediatric patients. Klimo P; Khalil A; Slotkin JR; Smith ER; Scott RM; Goumnerova LC Neurosurgery; 2007 Apr; 60(4 Suppl 2):305-9; discussion 309. PubMed ID: 17415167 [TBL] [Abstract][Full Text] [Related]
38. Tisseel® versus Hemopatch® for dural sealing in neurosurgery. A prospective study in a tertiary center. Diaz-Molina J; Martínez R; González-Vargas P; Calero L; Azevedo A; Conde C Neurochirurgie; 2020 Dec; 66(6):429-434. PubMed ID: 33091461 [TBL] [Abstract][Full Text] [Related]
39. Hemopatch® with fibrin glue as a dural sealant in cranial and spinal surgery. A technical note with a review of the literature. Montano N; Giordano M; Caccavella VM; Ioannoni E; Polli FM; Papacci F; Olivi A J Clin Neurosci; 2020 Sep; 79():144-147. PubMed ID: 33070884 [TBL] [Abstract][Full Text] [Related]
40. Watertight Dural Closure in Pediatric Craniotomies-Is It Really Necessary? Roth J; Benvenisti H; Constantini S World Neurosurg; 2018 Jun; 114():e743-e746. PubMed ID: 29551726 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]