These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
120 related articles for article (PubMed ID: 14595608)
1. Development of a dynamometer for measuring the isometric force of the pelvic floor musculature. Dumoulin C; Bourbonnais D; Lemieux MC Neurourol Urodyn; 2003; 22(7):648-53. PubMed ID: 14595608 [TBL] [Abstract][Full Text] [Related]
2. Reliability of dynamometric measurements of the pelvic floor musculature. Dumoulin C; Gravel D; Bourbonnais D; Lemieux MC; Morin M Neurourol Urodyn; 2004; 23(2):134-42. PubMed ID: 14983425 [TBL] [Abstract][Full Text] [Related]
3. Reliability of speed of contraction and endurance dynamometric measurements of the pelvic floor musculature in stress incontinent parous women. Morin M; Dumoulin C; Gravel D; Bourbonnais D; Lemieux MC Neurourol Urodyn; 2007; 26(3):397-403; discussion 404. PubMed ID: 17262833 [TBL] [Abstract][Full Text] [Related]
4. Pelvic floor muscle function in continent and stress urinary incontinent women using dynamometric measurements. Morin M; Bourbonnais D; Gravel D; Dumoulin C; Lemieux MC Neurourol Urodyn; 2004; 23(7):668-74. PubMed ID: 15382183 [TBL] [Abstract][Full Text] [Related]
5. Reliability of dynamometric passive properties of the pelvic floor muscles in postmenopausal women with stress urinary incontinence. Morin M; Gravel D; Bourbonnais D; Dumoulin C; Ouellet S Neurourol Urodyn; 2008; 27(8):819-25. PubMed ID: 18551559 [TBL] [Abstract][Full Text] [Related]
6. Force-length relationship in the pelvic floor muscles under transverse vaginal distension: a method study in healthy women. Verelst M; Leivseth G Neurourol Urodyn; 2004; 23(7):662-7. PubMed ID: 15382182 [TBL] [Abstract][Full Text] [Related]
8. Pelvic floor maximal strength using vaginal digital assessment compared to dynamometric measurements. Morin M; Dumoulin C; Bourbonnais D; Gravel D; Lemieux MC Neurourol Urodyn; 2004; 23(4):336-41. PubMed ID: 15227651 [TBL] [Abstract][Full Text] [Related]
9. Pelvic floor muscle strength and response to pelvic floor muscle training for stress urinary incontinence. Bø K Neurourol Urodyn; 2003; 22(7):654-8. PubMed ID: 14595609 [TBL] [Abstract][Full Text] [Related]
10. Force and stiffness of the pelvic floor as function of muscle length: A comparison between women with and without stress urinary incontinence. Verelst M; Leivseth G Neurourol Urodyn; 2007; 26(6):852-7. PubMed ID: 17563104 [TBL] [Abstract][Full Text] [Related]
11. Influence of pelvic floor muscle contraction on the profile of vaginal closure pressure in continent and stress urinary incontinent women. Shishido K; Peng Q; Jones R; Omata S; Constantinou CE J Urol; 2008 May; 179(5):1917-22. PubMed ID: 18353401 [TBL] [Abstract][Full Text] [Related]
12. Application of a new method in the study of pelvic floor muscle passive properties in continent women. Morin M; Gravel D; Bourbonnais D; Dumoulin C; Ouellet S; Pilon JF J Electromyogr Kinesiol; 2010 Oct; 20(5):795-803. PubMed ID: 19900822 [TBL] [Abstract][Full Text] [Related]
13. Direction sensitive sensor probe for the evaluation of voluntary and reflex pelvic floor contractions. Constantinou CE; Omata S Neurourol Urodyn; 2007; 26(3):386-91. PubMed ID: 17301962 [TBL] [Abstract][Full Text] [Related]
14. An automated intravaginal dynamometer: Reliability metrics and the impact of testing protocol on active and passive forces measured from the pelvic floor muscles. Bérubé MÈ; Czyrnyj CS; McLean L Neurourol Urodyn; 2018 Aug; 37(6):1875-1888. PubMed ID: 29635776 [TBL] [Abstract][Full Text] [Related]
15. [Muscle strength measurement of pelvic floor in women by vaginal dynamometer]. Parezanović-Ilić K; Jevtić M; Jeremić B; Arsenijević S Srp Arh Celok Lek; 2009; 137(9-10):511-7. PubMed ID: 19950758 [TBL] [Abstract][Full Text] [Related]
16. Test-retest reliability of the different dynamometric variables used to evaluate pelvic floor musculature during the menstrual cycle. Dos Reis Nagano RC; Biasotto-Gonzalez DA; da Costa GL; Amorim KM; Fumagalli MA; Amorim CF; Politti F Neurourol Urodyn; 2018 Nov; 37(8):2606-2613. PubMed ID: 29664139 [TBL] [Abstract][Full Text] [Related]
17. Reliability of bidirectional and variable-opening equipment for the measurement of pelvic floor muscle strength. Nunes FR; Martins CC; Guirro EC; Guirro RR PM R; 2011 Jan; 3(1):21-6. PubMed ID: 21257129 [TBL] [Abstract][Full Text] [Related]
18. Reliability of a new instrument for measuring plantarflexor muscle strength. Ortqvist M; Gutierrez-Farewik EM; Farewik M; Jansson A; Bartonek A; Broström E Arch Phys Med Rehabil; 2007 Sep; 88(9):1164-70. PubMed ID: 17826463 [TBL] [Abstract][Full Text] [Related]
19. Application of perineometer in the assessment of pelvic floor muscle strength and endurance: a reliability study. Rahmani N; Mohseni-Bandpei MA J Bodyw Mov Ther; 2011 Apr; 15(2):209-14. PubMed ID: 21419362 [TBL] [Abstract][Full Text] [Related]
20. Relationship between abdominal and pelvic floor muscle activation and intravaginal pressure during pelvic floor muscle contractions in healthy continent women. Madill SJ; McLean L Neurourol Urodyn; 2006; 25(7):722-30. PubMed ID: 16817184 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]