BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

276 related articles for article (PubMed ID: 14598119)

  • 1. Preliminary study of a new type of energy transmission system for artificial hearts.
    Ozeki T; Chinzei T; Abe Y; Saito I; Isoyama T; Ono T; Kouno A; Ishimaru M; Mochizuki S; Takiura K; Baba A; Toyama T; Imachi K
    J Artif Organs; 2003; 6(1):14-9. PubMed ID: 14598119
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device.
    Okamoto E; Yamamoto Y; Akasaka Y; Motomura T; Mitamura Y; Nosé Y
    Artif Organs; 2009 Aug; 33(8):622-6. PubMed ID: 19769776
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Development of an autotuned transcutaneous energy transfer system.
    Miller JA; Bélanger G; Mussivand T
    ASAIO J; 1993; 39(3):M706-10. PubMed ID: 8268629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Functions for detecting malposition of transcutaneous energy transmission coils.
    Ozeki T; Chinzei T; Abe Y; Saito I; Isoyama T; Mochizuki S; Ishimaru M; Takiura K; Baba A; Toyama T; Imachi K
    ASAIO J; 2003; 49(4):469-74. PubMed ID: 12918593
    [TBL] [Abstract][Full Text] [Related]  

  • 5. In vivo performance evaluation of a transcutaneous energy and information transmission system for the total artificial heart.
    Ahn JM; Kang DW; Kim HC; Min BG
    ASAIO J; 1993; 39(3):M208-12. PubMed ID: 8268530
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Improvement in magnetic field immunity of externally-coupled transcutaneous energy transmission system for a totally implantable artificial heart.
    Yamamoto T; Koshiji K; Homma A; Tatsumi E; Taenaka Y
    J Artif Organs; 2008; 11(4):238-40. PubMed ID: 19184291
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A solar cell system for extension of battery run time in a moving actuator total artificial heart.
    Ahn JM; Kim WE; Choi SW; Min BG; Kim WG
    ASAIO J; 1997; 43(5):M673-6. PubMed ID: 9360131
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intelligent Li ion battery management based on a digital signal processor for a moving actuator total artificial heart.
    Kim WE; Ahn JM; Choi SW; Min BG
    ASAIO J; 1997; 43(5):M588-92. PubMed ID: 9360113
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vivo evaluations of a transcutaneous energy transmission (TET) system.
    Sherman C; Daly BD; Clay W; Dasse K; Handrahan J; Haudenschild C
    Trans Am Soc Artif Intern Organs; 1984; 30():143-7. PubMed ID: 6398544
    [No Abstract]   [Full Text] [Related]  

  • 10. The artificial heart-- past, present, and future.
    Zareba KM
    Med Sci Monit; 2002 Mar; 8(3):RA72-7. PubMed ID: 11887044
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Investigation of unifying transcutaneous transformer for transmission of energy and information.
    Tamura N; Yamamoto T; Aoki H; Koshiji K; Homma A; Tatsumi E; Taenaka Y
    J Artif Organs; 2009; 12(2):138-40. PubMed ID: 19536632
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adaptive transcutaneous power delivery for an artificial anal sphincter system.
    Zan P; Yan G; Liu H; Luo N; Zhao Y
    J Med Eng Technol; 2009; 33(2):136-41. PubMed ID: 19085203
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasonic transcutaneous energy transfer using a continuous wave 650 kHz Gaussian shaded transmitter.
    Ozeri S; Shmilovitz D; Singer S; Wang CC
    Ultrasonics; 2010 Jun; 50(7):666-74. PubMed ID: 20219226
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A study on an energy supply method for a transcutaneous energy transmission system.
    Ozeki T; Chinzei T; Abe Y; Saito I; Isoyama T; Ono T; Kouno A; Ishimaru M; Takiura K; Baba A; Toyama T; Imachi K
    Artif Organs; 2003 Jan; 27(1):68-72. PubMed ID: 12534715
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Power transmission for gastrointestinal microsystems using inductive coupling.
    Guanying M; Guozheng Y; Xiu H
    Physiol Meas; 2007 Mar; 28(3):N9-18. PubMed ID: 17322587
    [TBL] [Abstract][Full Text] [Related]  

  • 16. FDTD assessment of human exposure to electromagnetic fields from WiFi and bluetooth devices in some operating situations.
    Martínez-Búrdalo M; Martín A; Sanchis A; Villar R
    Bioelectromagnetics; 2009 Feb; 30(2):142-51. PubMed ID: 18937345
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Research on wireless power transmission for gastrointestinal microsystems based on inductive coupling].
    Ma G; Yan G
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2008 Feb; 25(1):61-4, 87. PubMed ID: 18435258
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transcutaneous battery recharging by volume conduction and its circuit modeling.
    Tang Z; Sclabassi RJ; Sun C; Hackworth SA; Zhao J; Cui XT; Sun M
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():644-7. PubMed ID: 17945991
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [A wireless power transmission system for capsule endoscope].
    Xin W; Yan G; Wang W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Jun; 27(3):490-4. PubMed ID: 20649004
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A transcutaneous energy transmission system for artificial heart adapting to changing impedance.
    Fu Y; Hu L; Ruan X; Fu X
    Artif Organs; 2015 Apr; 39(4):378-87. PubMed ID: 25349072
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.