BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

234 related articles for article (PubMed ID: 14598128)

  • 1. Metal allergy to stainless steel wire after coronary artery bypass grafting.
    Takazawa K; Ishikawa N; Miyagawa H; Yamamoto T; Hariya A; Dohi S
    J Artif Organs; 2003; 6(1):71-2. PubMed ID: 14598128
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hypersensitivity reaction to sternal wires: a possible cause of persistent postoperative pain.
    Ancalmo N; Perniciaro C; Ochsner J
    Cardiovasc Surg; 1993 Aug; 1(4):439-41. PubMed ID: 8076076
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Sternal wire reaction with wire's skin exposure and its treatment in a patient who underwent coronary bypass surgery.
    Gökalp O; Yürekli I; Güneş T; Kestelli M; Yılık L; Lafçı B; Ozcem B; Gürbüz A
    Anadolu Kardiyol Derg; 2011 Mar; 11(2):E9-E10. PubMed ID: 21362592
    [No Abstract]   [Full Text] [Related]  

  • 4. Sternal Wires-Induced Severe Systemic Inflammatory Response and Cardiac Tamponade.
    Zywicka EM; Theologou T; Love S; Nawaytou O
    Ann Thorac Surg; 2019 Mar; 107(3):e175-e176. PubMed ID: 30266619
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Sternal wire-induced persistent chest pain: a possible hypersensitivity reaction.
    Fine PG; Karwande SV
    Ann Thorac Surg; 1990 Jan; 49(1):135-6. PubMed ID: 2297262
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Death due to disruption of sternal fixation wire--a rare complication after open heart surgery through sternotomy: report of a case.
    Chang H; Hung CR
    Taiwan Yi Xue Hui Za Zhi; 1989 Apr; 88(4):410-2. PubMed ID: 2794943
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Confirmation of Safety of Titanium Wire in Sternotomy Closure, A Randomized Prospective Study.
    Eraqi M; Diab AH; Matschke K; Alexiou K
    Thorac Cardiovasc Surg; 2024 Jan; 72(1):70-76. PubMed ID: 36918153
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fracture and migration of a sternal metal suture: a possible cause of post-coronary bypass intermittent chest pain.
    Turgeman Y; Atar S; Rosenfeld T
    Isr Med Assoc J; 2005 Jan; 7(1):52. PubMed ID: 15658151
    [No Abstract]   [Full Text] [Related]  

  • 9. The outcome of sternal wire removal on persistent anterior chest wall pain after median sternotomy.
    Nørgaard MA; Andersen TC; Lavrsen MJ; Borgeskov S
    Eur J Cardiothorac Surg; 2006 Jun; 29(6):920-4. PubMed ID: 16675252
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Corrosion of stainless steel sternal wire after long-term implantation.
    Tomizawa Y; Hanawa T; Kuroda D; Nishida H; Endo M
    J Artif Organs; 2006; 9(1):61-6. PubMed ID: 16614803
    [TBL] [Abstract][Full Text] [Related]  

  • 11. When it is not an infection: metal allergy after the Nuss procedure for repair of pectus excavatum.
    Rushing GD; Goretsky MJ; Gustin T; Morales M; Kelly RE; Nuss D
    J Pediatr Surg; 2007 Jan; 42(1):93-7. PubMed ID: 17208547
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Allergic reaction to stainless steel sternotomy wires requiring removal: A case report and literature review.
    Lopez J; Sachithanandan A; Leow M
    Med J Malaysia; 2016 Jun; 71(3):142-3. PubMed ID: 27495890
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Patch test reactivity to a cobalt-chromium-molybdenum alloy and stainless steel in metal-allergic patients in correlation to the metal ion release.
    Summer B; Fink U; Zeller R; Rueff F; Maier S; Roider G; Thomas P
    Contact Dermatitis; 2007 Jul; 57(1):35-9. PubMed ID: 17577355
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reaction to stainless steel wire following orthognathic surgery.
    Guyuron B; Lasa CI
    Plast Reconstr Surg; 1992 Mar; 89(3):540-2. PubMed ID: 1535843
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Degradation of 316L stainless steel sternal wire by steam sterilization.
    Shih CC; Su YY; Chen LC; Shih CM; Lin SJ
    Acta Biomater; 2010 Jun; 6(6):2322-8. PubMed ID: 20025998
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Ocular injury secondary to periorbital use of stainless-steel wire and suture.
    Yeatts RP; Harvey J; Bartley GB; Nerney JJ
    Arch Ophthalmol; 1994 Feb; 112(2):213-6. PubMed ID: 8311775
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical evaluation of cranial flap fixation techniques: comparative experimental study of suture, stainless steel wire, and rivetlike titanium clamp.
    Wang YR; Su ZP; Yang SX; Guo BY; Zeng YJ
    Ann Plast Surg; 2007 Apr; 58(4):388-91. PubMed ID: 17413880
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Immediate hypersensitivity type of occupational laryngitis in a welder exposed to welding fumes of stainless steel.
    Hannu T; Piipari R; Toskala E
    Am J Ind Med; 2006 May; 49(5):402-5. PubMed ID: 16570256
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Selective versus routine patch metal allergy testing to select bar material for the Nuss procedure in 932 patients over 10years.
    Obermeyer RJ; Gaffar S; Kelly RE; Kuhn MA; Frantz FW; McGuire MM; Paulson JF; Kelly CS
    J Pediatr Surg; 2018 Feb; 53(2):260-264. PubMed ID: 29223667
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Large subpectoral hematoma: possible complication of sternotomy post-cardiac surgery.
    Fallouh HB; Venugopal PS; Chambers AJ; Govewalla P; Maruyama Y; Bhusari S
    Ann Thorac Cardiovasc Surg; 2009 Jun; 15(3):192-3. PubMed ID: 19597398
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.