229 related articles for article (PubMed ID: 14602674)
1. Fume generation and content of total chromium and hexavalent chromium in flux-cored arc welding.
Yoon CS; Paik NW; Kim JH
Ann Occup Hyg; 2003 Nov; 47(8):671-80. PubMed ID: 14602674
[TBL] [Abstract][Full Text] [Related]
2. Profiling stainless steel welding processes to reduce fume emissions, hexavalent chromium emissions and operating costs in the workplace.
Keane M; Siert A; Stone S; Chen BT
J Occup Environ Hyg; 2016; 13(1):1-8. PubMed ID: 26267301
[TBL] [Abstract][Full Text] [Related]
3. Selecting Processes to Minimize Hexavalent Chromium from Stainless Steel Welding: Eight welding processes/shielding gas combinations were assessed for generation of hexavalent chromium in stainless steel welding fumes.
Keane M; Siert A; Stone S; Chen B; Slaven J; Cumpston A; Antonini J
Weld J; 2012 Sep; 91(9):241s-246s. PubMed ID: 26690276
[TBL] [Abstract][Full Text] [Related]
4. Characterization of Particulate Fume and Oxides Emission from Stainless Steel Plasma Cutting.
Wang J; Hoang T; Floyd EL; Regens JL
Ann Work Expo Health; 2017 Apr; 61(3):311-320. PubMed ID: 28355418
[TBL] [Abstract][Full Text] [Related]
5. Profiling mild steel welding processes to reduce fume emissions and costs in the workplace.
Keane MJ; Siert A; Chen BT; Stone SG
Ann Occup Hyg; 2014 May; 58(4):403-12. PubMed ID: 24515891
[TBL] [Abstract][Full Text] [Related]
6. [Assessment of occupational exposure of welders based on determination of fumes and their components produced during stainless steel welding].
Stanisławska M; Janasik B; Trzcinka-Ochocka M
Med Pr; 2011; 62(4):359-68. PubMed ID: 21995105
[TBL] [Abstract][Full Text] [Related]
7. Control of Cr6+ emissions from gas metal arc welding using a silica precursor as a shielding gas additive.
Topham N; Wang J; Kalivoda M; Huang J; Yu KM; Hsu YM; Wu CY; Oh S; Cho K; Paulson K
Ann Occup Hyg; 2012 Mar; 56(2):233-41. PubMed ID: 22104317
[TBL] [Abstract][Full Text] [Related]
8. A Field Study on the Respiratory Deposition of the Nano-Sized Fraction of Mild and Stainless Steel Welding Fume Metals.
Cena LG; Chisholm WP; Keane MJ; Chen BT
J Occup Environ Hyg; 2015; 12(10):721-8. PubMed ID: 25985454
[TBL] [Abstract][Full Text] [Related]
9. An evaluation of welding processes to reduce hexavalent chromium exposures and reduce costs by using better welding techniques.
Keane MJ
Environ Health Insights; 2014; 8(Suppl 1):47-50. PubMed ID: 25574138
[TBL] [Abstract][Full Text] [Related]
10. Hexavalent chromium content in stainless steel welding fumes is dependent on the welding process and shield gas type.
Keane M; Stone S; Chen B; Slaven J; Schwegler-Berry D; Antonini J
J Environ Monit; 2009 Feb; 11(2):418-24. PubMed ID: 19212602
[TBL] [Abstract][Full Text] [Related]
11. High variability in toxicity of welding fume nanoparticles from stainless steel in lung cells and reporter cell lines: the role of particle reactivity and solubility.
McCarrick S; Wei Z; Moelijker N; Derr R; Persson KA; Hendriks G; Odnevall Wallinder I; Hedberg Y; Karlsson HL
Nanotoxicology; 2019 Dec; 13(10):1293-1309. PubMed ID: 31418618
[TBL] [Abstract][Full Text] [Related]
12. Control of occupational exposure to hexavalent chromium and ozone in tubular wire arc-welding processes by replacement of potassium by lithium or by addition of zinc.
Dennis JH; French MJ; Hewitt PJ; Mortazavi SB; Redding CA
Ann Occup Hyg; 2002 Jan; 46(1):33-42. PubMed ID: 12005130
[TBL] [Abstract][Full Text] [Related]
13. Control of exposure to hexavalent chromium concentration in shielded metal arc welding fumes by nano-coating of electrodes.
Sivapirakasam SP; Mohan S; Santhosh Kumar MC; Thomas Paul A; Surianarayanan M
Int J Occup Environ Health; 2017 Apr; 23(2):128-142. PubMed ID: 29460694
[TBL] [Abstract][Full Text] [Related]
14. Exposure to hexavalent chromium in welders: Results of the WELDOX II field study.
Pesch B; Lehnert M; Weiss T; Kendzia B; Menne E; Lotz A; Heinze E; Behrens T; Gabriel S; Schneider W; Brüning T
Ann Work Expo Health; 2018 Mar; 62(3):351-361. PubMed ID: 29444199
[TBL] [Abstract][Full Text] [Related]
15. Airborne exposure to inhalable hexavalent chromium in welders and other occupations: Estimates from the German MEGA database.
Pesch B; Kendzia B; Hauptmann K; Van Gelder R; Stamm R; Hahn JU; Zschiesche W; Behrens T; Weiss T; Siemiatycki J; Lavoué J; Jöckel KH; Brüning T
Int J Hyg Environ Health; 2015 Jul; 218(5):500-6. PubMed ID: 25979374
[TBL] [Abstract][Full Text] [Related]
16. Relation between various chromium compounds and some other elements in fumes from manual metal arc stainless steel welding.
Matczak W; Chmielnicka J
Br J Ind Med; 1993 Mar; 50(3):244-51. PubMed ID: 8457491
[TBL] [Abstract][Full Text] [Related]
17. Welding fumes from stainless steel gas metal arc processes contain multiple manganese chemical species.
Keane M; Stone S; Chen B
J Environ Monit; 2010 May; 12(5):1133-40. PubMed ID: 21491680
[TBL] [Abstract][Full Text] [Related]
18. Urine chromium as an estimator of air exposure to stainless steel welding fumes.
Sjögren B; Hedström L; Ulfvarson U
Int Arch Occup Environ Health; 1983; 51(4):347-54. PubMed ID: 6862648
[TBL] [Abstract][Full Text] [Related]
19. Human biomonitoring of chromium and nickel from an experimental exposure to manual metal arc welding fumes of low and high alloyed steel.
Bertram J; Brand P; Schettgen T; Lenz K; Purrio E; Reisgen U; Kraus T
Ann Occup Hyg; 2015 May; 59(4):467-80. PubMed ID: 25512666
[TBL] [Abstract][Full Text] [Related]
20. A novel method for assessing respiratory deposition of welding fume nanoparticles.
Cena LG; Keane MJ; Chisholm WP; Stone S; Harper M; Chen BT
J Occup Environ Hyg; 2014; 11(12):771-80. PubMed ID: 24824154
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]