These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
24. A retrospective analysis of five intra-ocular lenses and the predictive value of six different intra-ocular lens power calculation formulas. Zuidervaart W; Luyten GP Ophthalmologica; 2005; 219(6):390-3. PubMed ID: 16286801 [TBL] [Abstract][Full Text] [Related]
25. Accuracy of predicted refraction with multifocal intraocular lenses using two biometry measurement devices and multiple intraocular lens power calculation formulas. Reitblat O; Assia EI; Kleinmann G; Levy A; Barrett GD; Abulafia A Clin Exp Ophthalmol; 2015; 43(4):328-34. PubMed ID: 25491591 [TBL] [Abstract][Full Text] [Related]
29. Deliberate use of unequal adds with aspheric ReSTOR intraocular lens. Osher RH J Cataract Refract Surg; 2009 Sep; 35(9):1646. PubMed ID: 19683171 [No Abstract] [Full Text] [Related]
30. Intraocular lens power calculation by ray-tracing after myopic excimer laser surgery. Savini G; Bedei A; Barboni P; Ducoli P; Hoffer KJ Am J Ophthalmol; 2014 Jan; 157(1):150-153.e1. PubMed ID: 24099275 [TBL] [Abstract][Full Text] [Related]
31. Evaluation of the synchrony dual-optic accommodating intraocular lens. Sergienko N J Cataract Refract Surg; 2008 Jan; 34(1):8-9; author reply 9. PubMed ID: 18165063 [No Abstract] [Full Text] [Related]
32. Intraoperative Aberrometry and Intraocular Lens Power Calculation. Galvis V; Tello A; Sacoto JI J Refract Surg; 2016 Feb; 32(2):138. PubMed ID: 26856435 [No Abstract] [Full Text] [Related]
33. Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses. Fam HB; Lim KL J Cataract Refract Surg; 2007 Dec; 33(12):2072-6. PubMed ID: 18053907 [TBL] [Abstract][Full Text] [Related]
34. Comparison of IOL power calculation formulae for pediatric eyes. Vasavada V; Shah SK; Vasavada VA; Vasavada AR; Trivedi RH; Srivastava S; Vasavada SA Eye (Lond); 2016 Sep; 30(9):1242-50. PubMed ID: 27494083 [TBL] [Abstract][Full Text] [Related]
35. Shifts in intraocular lens optic configuration may induce errors in intraocular lens power calculation. Olsen T; Melles RB J Cataract Refract Surg; 2023 Feb; 49(2):215-216. PubMed ID: 36700890 [No Abstract] [Full Text] [Related]
36. Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens. Moreno LJ; Piñero DP; Alió JL; Fimia A; Plaza AB J Cataract Refract Surg; 2010 Dec; 36(12):2048-55. PubMed ID: 21111306 [TBL] [Abstract][Full Text] [Related]
37. Discrepancies between intraocular lens implant power prediction formulas in pediatric patients. Eibschitz-Tsimhoni M; Tsimhoni O; Archer SM; Del Monte MA Ophthalmology; 2007 Feb; 114(2):383-6. PubMed ID: 17270686 [TBL] [Abstract][Full Text] [Related]
38. Intraocular lens power calculation errors in long eyes. Olsen T J Cataract Refract Surg; 2012 Apr; 38(4):733-4; author reply 734. PubMed ID: 22440455 [No Abstract] [Full Text] [Related]