These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
269 related articles for article (PubMed ID: 14606793)
1. Scanning electron microscope observations of new and used nickel-titanium rotary files. Alapati SB; Brantley WA; Svec TA; Powers JM; Mitchell JC J Endod; 2003 Oct; 29(10):667-9. PubMed ID: 14606793 [TBL] [Abstract][Full Text] [Related]
2. Wear of nickel-titanium lightspeed instruments evaluated by scanning electron microscopy. Eggert C; Peters O; Barbakow F J Endod; 1999 Jul; 25(7):494-7. PubMed ID: 10687515 [TBL] [Abstract][Full Text] [Related]
3. The deterioration of rotary nickel-titanium files under controlled conditions. Svec TA; Powers JM J Endod; 2002 Feb; 28(2):105-7. PubMed ID: 11833680 [TBL] [Abstract][Full Text] [Related]
4. A scanning electron microscopy evaluation of microfractures, deformation and separation in EndoSequence and Profile nickel-titanium rotary files using an extracted molar tooth model. Herold KS; Johnson BR; Wenckus CS J Endod; 2007 Jun; 33(6):712-4. PubMed ID: 17509412 [TBL] [Abstract][Full Text] [Related]
5. SEM observations and differential scanning calorimetric studies of new and sterilized nickel-titanium rotary endodontic instruments. Alexandrou GB; Chrissafis K; Vasiliadis LP; Pavlidou E; Polychroniadis EK J Endod; 2006 Jul; 32(7):675-9. PubMed ID: 16793479 [TBL] [Abstract][Full Text] [Related]
6. Comparative investigation of two rotary nickel-titanium instruments: ProTaper versus RaCe. Part 2. Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth. Schäfer E; Vlassis M Int Endod J; 2004 Apr; 37(4):239-48. PubMed ID: 15056350 [TBL] [Abstract][Full Text] [Related]
7. Proposed role of embedded dentin chips for the clinical failure of nickel-titanium rotary instruments. Alapati SB; Brantley WA; Svec TA; Powers JM; Nusstein JM; Daehn GS J Endod; 2004 May; 30(5):339-41. PubMed ID: 15107646 [TBL] [Abstract][Full Text] [Related]
8. The shaping effects of three nickel-titanium rotary instruments on preparing curved canals in posterior teeth. Wei X; Ling J; Zhang S Zhonghua Kou Qiang Yi Xue Za Zhi; 2002 Sep; 37(5):333-5. PubMed ID: 12425841 [TBL] [Abstract][Full Text] [Related]
9. Decrease in the fatigue resistance of nickel-titanium rotary instruments after clinical use in curved root canals. Bahia MG; Buono VT Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2005 Aug; 100(2):249-55. PubMed ID: 16037784 [TBL] [Abstract][Full Text] [Related]