These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

327 related articles for article (PubMed ID: 14609674)

  • 21. Effect of impact assembly on the fretting corrosion of modular hip tapers.
    Mroczkowski ML; Hertzler JS; Humphrey SM; Johnson T; Blanchard CR
    J Orthop Res; 2006 Feb; 24(2):271-9. PubMed ID: 16435360
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Deposition of highly adhesive ZrO(2) coating on Ti and CoCrMo implant materials using plasma spraying.
    Yang Y; Ong JL; Tian J
    Biomaterials; 2003 Feb; 24(4):619-27. PubMed ID: 12437956
    [TBL] [Abstract][Full Text] [Related]  

  • 23. The effect of the inflammatory species hypochlorous acid on the corrosion and surface damage of Ti-6Al-4V and CoCrMo alloys.
    Kubacki GW; Gilbert JL
    J Biomed Mater Res A; 2018 Dec; 106(12):3185-3194. PubMed ID: 30151943
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Biomechanical implant fixation of CoCrMo coating inferior to titanium coating in a canine implant model.
    Jakobsen SS; Baas J; Jakobsen T; Soballe K
    J Biomed Mater Res A; 2010 Jul; 94(1):180-6. PubMed ID: 20128008
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Cobalt-based alloys for orthopaedic applications studied by electrochemical and XPS analysis.
    Kocijan A; Milosev I; Pihlar B
    J Mater Sci Mater Med; 2004 Jun; 15(6):643-50. PubMed ID: 15346730
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Modification of Ti6Al4V implant surfaces by biocompatible TiO
    Catauro M; Bollino F; Giovanardi R; Veronesi P
    Mater Sci Eng C Mater Biol Appl; 2017 May; 74():501-507. PubMed ID: 28254324
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Interfacial compliance, energy dissipation, frequency effects, and long-term fretting corrosion performance of Ti-6Al-4V/CoCrMo interfaces.
    Smith SM; Gilbert JL
    J Biomed Mater Res A; 2022 Feb; 110(2):409-423. PubMed ID: 34402604
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Nano-scale study of the nucleation and growth of calcium phosphate coating on titanium implants.
    Barrere F; Snel MM; van Blitterswijk CA; de Groot K; Layrolle P
    Biomaterials; 2004 Jun; 25(14):2901-10. PubMed ID: 14962569
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Surface hardening by anodizing and heat treatments of Ti6Al4V alloys for articular prostheses.
    Gil FJ; Ginebra MP; Planell JA
    Biomed Mater Eng; 2002; 12(3):271-81. PubMed ID: 12446942
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Microstructure, Wettability, Corrosion Resistance and Antibacterial Property of Cu-MTa
    Ding Z; Wang Y; Zhou Q; Ding Z; Liu J; He Q; Zhang H
    Biomolecules; 2019 Dec; 10(1):. PubMed ID: 31906220
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Hybrid diffusive/PVD treatments to improve the tribological resistance of Ti-6Al-4V.
    Marin E; Offoiach R; Lanzutti A; Regis M; Fusi S; Fedrizzi L
    Biomed Mater Eng; 2014; 24(1):581-92. PubMed ID: 24211942
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In situ synthesized TiB-TiN reinforced Ti6Al4V alloy composite coatings: microstructure, tribological and in-vitro biocompatibility.
    Das M; Bhattacharya K; Dittrick SA; Mandal C; Balla VK; Sampath Kumar TS; Bandyopadhyay A; Manna I
    J Mech Behav Biomed Mater; 2014 Jan; 29():259-71. PubMed ID: 24121827
    [TBL] [Abstract][Full Text] [Related]  

  • 33. In vitro assessment of strength, fatigue durability, and disassembly of Ti6Al4V and CoCrMo necks in modular total hip replacements.
    Nganbe M; Khan U; Louati H; Speirs A; Beaulé PE
    J Biomed Mater Res B Appl Biomater; 2011 Apr; 97(1):132-8. PubMed ID: 21290591
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Alloys Used in Different Temporomandibular Joint Reconstruction Replacement Prostheses Exhibit Variable Microstructures and Electrochemical Properties.
    Neto MQ; Radice S; Hall DJ; Mathew MT; Mercuri LG; Pourzal R
    J Oral Maxillofac Surg; 2022 May; 80(5):798-813. PubMed ID: 35157828
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Electrochemical, Tribological and Biocompatible Performance of Electron Beam Modified and Coated Ti6Al4V Alloy.
    Nikolova M; Ormanova M; Nikolova V; Apostolova MD
    Int J Mol Sci; 2021 Jun; 22(12):. PubMed ID: 34198700
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effects of hip implant modular neck material and assembly method on fatigue life and distraction force.
    Aljenaei F; Catelas I; Louati H; Beaulé PE; Nganbe M
    J Orthop Res; 2017 Sep; 35(9):2023-2030. PubMed ID: 27862223
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Cytocompatibility of implants coated with titanium nitride and zirconium nitride.
    Prachar P; Bartakova S; Brezina V; Cvrcek L; Vanek J
    Bratisl Lek Listy; 2015; 116(3):154-6. PubMed ID: 25869562
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Characterization of the 3YSZ/CNT/HAP coating on the Ti6Al4V alloy by electrophoretic deposition.
    Naseri H; Ghatee M; Yazdani A; Mohammadi M; Manafi S
    J Biomed Mater Res B Appl Biomater; 2021 Oct; 109(10):1395-1406. PubMed ID: 33484113
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Electrochemical behavior of different preparations of plasma-sprayed hydroxyapatite coatings on Ti6Al4V substrate.
    Souto RM; Lemus MM; Reis RL
    J Biomed Mater Res A; 2004 Jul; 70(1):59-65. PubMed ID: 15174109
    [TBL] [Abstract][Full Text] [Related]  

  • 40. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads.
    Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E
    Proc Inst Mech Eng H; 2002; 216(4):219-30. PubMed ID: 12206518
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 17.