208 related articles for article (PubMed ID: 14611755)
1. Hydrogels of a conducting conjugated polymer as 3-D enzyme electrode.
Asberg P; Inganäs O
Biosens Bioelectron; 2003 Nov; 19(3):199-207. PubMed ID: 14611755
[TBL] [Abstract][Full Text] [Related]
2. Direct electrochemistry of horseradish peroxidase bonded on a conducting polymer modified glassy carbon electrode.
Kong YT; Boopathi M; Shim YB
Biosens Bioelectron; 2003 Nov; 19(3):227-32. PubMed ID: 14611758
[TBL] [Abstract][Full Text] [Related]
3. Hydrogen peroxide sensitive amperometric biosensor based on horseradish peroxidase entrapped in a polypyrrole electrode.
Razola SS; Ruiz BL; Diez NM; Mark HB; Kauffmann JM
Biosens Bioelectron; 2002 Dec; 17(11-12):921-8. PubMed ID: 12392940
[TBL] [Abstract][Full Text] [Related]
4. A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode.
Cao S; Yuan R; Chai Y; Zhang L; Li X; Gao F
Bioprocess Biosyst Eng; 2007 Mar; 30(2):71-8. PubMed ID: 17242931
[TBL] [Abstract][Full Text] [Related]
5. The potential use of hydrazine as an alternative to peroxidase in a biosensor: comparison between hydrazine and HRP-based glucose sensors.
Rahman MA; Won MS; Shim YB
Biosens Bioelectron; 2005 Aug; 21(2):257-65. PubMed ID: 16023952
[TBL] [Abstract][Full Text] [Related]
6. Conducting polymer transistors making use of activated carbon gate electrodes.
Tang H; Kumar P; Zhang S; Yi Z; Crescenzo GD; Santato C; Soavi F; Cicoira F
ACS Appl Mater Interfaces; 2015 Jan; 7(1):969-73. PubMed ID: 25510960
[TBL] [Abstract][Full Text] [Related]
7. HRP-based biosensor for monitoring rifampicin.
Alonso Lomillo MA; Kauffmann JM; Arcos Martinez MJ
Biosens Bioelectron; 2003 Aug; 18(9):1165-71. PubMed ID: 12788559
[TBL] [Abstract][Full Text] [Related]
8. Conducting polymers on hydrogel-coated neural electrode provide sensitive neural recordings in auditory cortex.
Kim DH; Wiler JA; Anderson DJ; Kipke DR; Martin DC
Acta Biomater; 2010 Jan; 6(1):57-62. PubMed ID: 19651250
[TBL] [Abstract][Full Text] [Related]
9. Enhanced electron-transfer reactivity of horseradish peroxidase in phosphatidylcholine films and its catalysis to nitric oxide.
Liu X; Zhang W; Huang Y; Li G
J Biotechnol; 2004 Mar; 108(2):145-52. PubMed ID: 15129723
[TBL] [Abstract][Full Text] [Related]
10. A new film for the fabrication of an unmediated H2O2 biosensor.
Xu Y; Peng W; Liu X; Li G
Biosens Bioelectron; 2004 Oct; 20(3):533-7. PubMed ID: 15494236
[TBL] [Abstract][Full Text] [Related]
11. Reagentless amperometric immunosensor for human chorionic gonadotrophin based on direct electrochemistry of horseradish peroxidase.
Chen J; Yan F; Dai Z; Ju H
Biosens Bioelectron; 2005 Aug; 21(2):330-6. PubMed ID: 16023960
[TBL] [Abstract][Full Text] [Related]
12. Hybrid bioelectrocatalyst for hydrogen peroxide reduction: immobilization of enzyme within organic-inorganic film of structured Prussian Blue and PEDOT.
Ernst A; Makowski O; Kowalewska B; Miecznikowski K; Kulesza PJ
Bioelectrochemistry; 2007 Sep; 71(1):23-8. PubMed ID: 17289445
[TBL] [Abstract][Full Text] [Related]
13. Electrocatalytic oxidation of NADH at gold nanoparticles loaded poly(3,4-ethylenedioxythiophene)-poly(styrene sulfonic acid) film modified electrode and integration of alcohol dehydrogenase for alcohol sensing.
Manesh KM; Santhosh P; Gopalan A; Lee KP
Talanta; 2008 Jun; 75(5):1307-14. PubMed ID: 18585217
[TBL] [Abstract][Full Text] [Related]
14. Characterisation of horseradish peroxidase immobilisation on an electrochemical biosensor by colorimetric and amperometric techniques.
Morrin A; Guzman A; Killard AJ; Pingarron JM; Smyth MR
Biosens Bioelectron; 2003 May; 18(5-6):715-20. PubMed ID: 12706583
[TBL] [Abstract][Full Text] [Related]
15. Electrochemical paper based cancer biosensor using iron oxide nanoparticles decorated PEDOT:PSS.
Kumar S; Umar M; Saifi A; Kumar S; Augustine S; Srivastava S; Malhotra BD
Anal Chim Acta; 2019 May; 1056():135-145. PubMed ID: 30797454
[TBL] [Abstract][Full Text] [Related]
16. Bi-enzyme sensor based on thick-film carbon electrode modified with electropolymerized tyramine.
Suprun EV; Budnikov HC; Evtugyn GA; Brainina KhZ
Bioelectrochemistry; 2004 Jun; 63(1-2):281-4. PubMed ID: 15110288
[TBL] [Abstract][Full Text] [Related]
17. Reagentless biosensors based on co-entrapment of a soluble redox polymer and an enzyme within an electrochemically deposited polymer film.
Vilkanauskyte A; Erichsen T; Marcinkeviciene L; Laurinavicius V; Schuhmann W
Biosens Bioelectron; 2002 Dec; 17(11-12):1025-31. PubMed ID: 12392952
[TBL] [Abstract][Full Text] [Related]
18. New glucose biosensor based on glucose oxidase-immobilized gelatin film coated electrodes.
Sungur S; Emregül E; Günendi G; Numanoğlu Y
J Biomater Appl; 2004 Apr; 18(4):265-77. PubMed ID: 15070514
[TBL] [Abstract][Full Text] [Related]
19. A highly sensitive electrochemical biosensor for catechol using conducting polymer reduced graphene oxide-metal oxide enzyme modified electrode.
Sethuraman V; Muthuraja P; Anandha Raj J; Manisankar P
Biosens Bioelectron; 2016 Oct; 84():112-9. PubMed ID: 26751827
[TBL] [Abstract][Full Text] [Related]
20. Nano fabrication of conducting polymers for NO gas by Dip pen nanolithography.
Lu HH; Lin CY; Hsiao TC; Ho KC; Tunney J; Yang D; Evoy S; Lee CK; Lin CW
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2253-6. PubMed ID: 18002439
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]