These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

29 related articles for article (PubMed ID: 14616536)

  • 1. Resistance valves in circulatory loops have a significant impact on
    Wu P; Bai Y; Du G; Zhang L; Zhao X
    Front Physiol; 2023; 14():1287207. PubMed ID: 38098804
    [No Abstract]   [Full Text] [Related]  

  • 2. Hemolysis of red blood cells in blood vessels modeled via computational fluid dynamics.
    Jędrzejczak K; Makowski Ł; Orciuch W; Wojtas K; Kozłowski M
    Int J Numer Method Biomed Eng; 2023 Nov; 39(11):e3699. PubMed ID: 36949568
    [TBL] [Abstract][Full Text] [Related]  

  • 3. On the Discretization of the Power-Law Hemolysis Model.
    Faghih MM; Islam A; Sharp MK
    J Biomech Eng; 2021 Jan; 143(1):. PubMed ID: 32793961
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Cell-scale hemolysis evaluation of intervenient ventricular assist device based on dissipative particle dynamics.
    Xu Z; Chen C; Hao P; He F; Zhang X
    Front Physiol; 2023; 14():1181423. PubMed ID: 37476687
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CFD-Based Flow Channel Optimization and Performance Prediction for a Conical Axial Maglev Blood Pump.
    Yang W; Peng S; Xiao W; Hu Y; Wu H; Li M
    Sensors (Basel); 2022 Feb; 22(4):. PubMed ID: 35214544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemolytic Performance in Two Generations of the Sputnik Left Ventricular Assist Device: A Combined Numerical and Experimental Study.
    Romanova AN; Pugovkin AA; Denisov MV; Ephimov IA; Gusev DV; Walter M; Groth T; Bockeria OL; Le TG; Satyukova AS; Selishchev SV; Telyshev DV
    J Funct Biomater; 2022 Jan; 13(1):. PubMed ID: 35076513
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Prediction of mechanical hemolysis in medical devices via a Lagrangian strain-based multiscale model.
    Nikfar M; Razizadeh M; Zhang J; Paul R; Wu ZJ; Liu Y
    Artif Organs; 2020 Aug; 44(8):E348-E368. PubMed ID: 32017130
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational fluid dynamics-based study of possibility of generating pulsatile blood flow via a continuous-flow VAD.
    Nammakie E; Niroomand-Oscuii H; Koochaki M; Ghalichi F
    Med Biol Eng Comput; 2017 Jan; 55(1):167-178. PubMed ID: 27234039
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparative Study of Continuous and Pulsatile Left Ventricular Assist Devices on Hemodynamics of a Pediatric End-to-Side Anastomotic Graft.
    Yang N; Deutsch S; Paterson EG; Manning KB
    Cardiovasc Eng Technol; 2010 Mar; 1(1):. PubMed ID: 24348881
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The use of computational fluid dynamics in the development of ventricular assist devices.
    Fraser KH; Taskin ME; Griffith BP; Wu ZJ
    Med Eng Phys; 2011 Apr; 33(3):263-80. PubMed ID: 21075669
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics.
    Apel J; Paul R; Klaus S; Siess T; Reul H
    Artif Organs; 2001 May; 25(5):341-7. PubMed ID: 11403662
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental and Numerical Investigation of an Axial Rotary Blood Pump.
    Schüle CY; Thamsen B; Blümel B; Lommel M; Karakaya T; Paschereit CO; Affeld K; Kertzscher U
    Artif Organs; 2016 Nov; 40(11):E192-E202. PubMed ID: 27087467
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A Review of Hemolysis Prediction Models for Computational Fluid Dynamics.
    Yu H; Engel S; Janiga G; Thévenin D
    Artif Organs; 2017 Jul; 41(7):603-621. PubMed ID: 28643335
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Progress in the analysis of hemolysis and coagulation models for interventional micro-axial flow blood pumps].
    Wang S; Fu H; Lu Z; Yang M
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2024 Apr; 41(2):383-388. PubMed ID: 38686421
    [TBL] [Abstract][Full Text] [Related]  

  • 15. An estimation method of hemolysis within an axial flow blood pump by computational fluid dynamics analysis.
    Yano T; Sekine K; Mitoh A; Mitamura Y; Okamoto E; Kim DW; Nishimura I; Murabayashi S; Yozu R
    Artif Organs; 2003 Oct; 27(10):920-5. PubMed ID: 14616536
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Computational fluid dynamics analysis of an intra-cardiac axial flow pump.
    Mitoh A; Yano T; Sekine K; Mitamura Y; Okamoto E; Kim DW; Yozu R; Kawada S
    Artif Organs; 2003 Jan; 27(1):34-40. PubMed ID: 12534711
    [TBL] [Abstract][Full Text] [Related]  

  • 17.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 18.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 19.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

  • 20.
    ; ; . PubMed ID:
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 2.