These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 14625747)

  • 1. Comparison of the performance of the Gea extracorporeal knot with the Roeder extracorporeal knot and the classical knot.
    Moreno M; Magos FJ; Arcovedo R; Olachea P; Palacios JA; Salazar A; Ramírez ME; Herrera JJ
    Surg Endosc; 2004 Jan; 18(1):157-60. PubMed ID: 14625747
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Laparoscopic knot security.
    Sedlack JD; Williams VM; DeSimone J; Page D; Ghosh BC
    Surg Laparosc Endosc; 1996 Apr; 6(2):144-6. PubMed ID: 8680638
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An optimal instrument-tied extracorporeal slip knot: a further note of caution.
    Ng JW; Yeung BB
    ANZ J Surg; 2005 Oct; 75(10):922-3. PubMed ID: 16176244
    [No Abstract]   [Full Text] [Related]  

  • 4. The relationship between five kinds of laparoscopic knots and five types of suture materials and histological findings in tissues: an experimental study on rabbits.
    Patsalos C; Karavias D; Stavropoulos M; Tierris I; Bablekos G; Nicolaou I; Androulakis I
    Surg Laparosc Endosc Percutan Tech; 2003 Jun; 13(3):202-7. PubMed ID: 12819506
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of tensile and knot security properties of surgical sutures.
    Kim JC; Lee YK; Lim BS; Rhee SH; Yang HC
    J Mater Sci Mater Med; 2007 Dec; 18(12):2363-9. PubMed ID: 17569012
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Laparoscopic knot tying].
    Barabás L; Sipos P
    Magy Seb; 2008 Jun; 61(3):116-20. PubMed ID: 18515215
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Knot security of suture materials.
    Rosin E; Robinson GM
    Vet Surg; 1989; 18(4):269-73. PubMed ID: 2505438
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A comparison of the strength of knots tied by hand and at laparoscopy.
    Kadirkamanathan SS; Shelton JC; Hepworth CC; Laufer JG; Swain CP
    J Am Coll Surg; 1996 Jan; 182(1):46-54. PubMed ID: 8542089
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A simple modification to add strength to the Roeder knot.
    Sharp HT; Dorsey JH; Chovan JD; Holtz PM
    J Am Assoc Gynecol Laparosc; 1996 Feb; 3(2):305-7. PubMed ID: 9050646
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Suture materials and suturing techniques.
    Campbell JR; Marks A
    In Pract; 1985 May; 7(3):72-5. PubMed ID: 2991140
    [No Abstract]   [Full Text] [Related]  

  • 11. Mechanical performance of polyglycolic acid and polyglactin 910 synthetic absorbable sutures.
    Rodeheaver GT; Thacker JG; Edlich RF
    Surg Gynecol Obstet; 1981 Dec; 153(6):835-41. PubMed ID: 6272438
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparative study of the holding strength of slipknots using absorbable and nonabsorbable ligature materials.
    Shimi SM; Lirici M; Vander Velpen G; Cuschieri A
    Surg Endosc; 1994 Nov; 8(11):1285-91. PubMed ID: 7831597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical performance of a braided absorbable suture.
    Faulkner BC; Gear AJ; Hellewell TB; Mazzarese PM; Watkins FH; Edlich RF
    J Long Term Eff Med Implants; 1996; 6(3-4):169-79. PubMed ID: 10167359
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A biomechanical study of laparoscopic 4S-modified Roeder and Weston knot strength in 3-0 polyglactin 910 and 3-0 polydioxanone.
    Fugazzi RW; Fransson BA; Curran KM; Davis HM; Gay JM
    Vet Surg; 2013 Feb; 42(2):198-204. PubMed ID: 23215860
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Old habits tie hard: an in vitro comparison of first-throw tension holding in Polyglycolic acid (Dexon S) and Polyglactin 910 (Coated Vicryl).
    Kersey TL; Patel S; Thaller VT
    Clin Exp Ophthalmol; 2006 Mar; 34(2):152-5. PubMed ID: 16626430
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of intracorporeal knot-tying suture (polyglactin) and titanium endoclips in laparoscopic appendiceal stump closure: a prospective randomized study.
    Ates M; Dirican A; Ince V; Ara C; Isik B; Yilmaz S
    Surg Laparosc Endosc Percutan Tech; 2012 Jun; 22(3):226-31. PubMed ID: 22678318
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Safety of vessel ligation in laparoscopic surgery.
    Nathanson LK; Nathanson PD; Cuschieri A
    Endoscopy; 1991 Jul; 23(4):206-9. PubMed ID: 1833179
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Laparoscopic knot substitutes. An assessment of techniques of securing sutures through the laparoscope.
    Andrews SM; Lewis JL
    Endosc Surg Allied Technol; 1994 Feb; 2(1):62-5. PubMed ID: 8081918
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of knot security of commonly used hand-tied laparoscopic slipknots.
    Shettko DL; Frisbie DD; Hendrickson DA
    Vet Surg; 2004; 33(5):521-4. PubMed ID: 15362991
    [TBL] [Abstract][Full Text] [Related]  

  • 20. How reliable is intracorporeal laparoscopic knot tying?
    Lopez PJ; Veness J; Wojcik A; Curry J
    J Laparoendosc Adv Surg Tech A; 2006 Aug; 16(4):428-32. PubMed ID: 16968200
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.