These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 14627313)

  • 1. Pressure recovery in pediatric aortic valve stenosis.
    Villavicencio RE; Forbes TJ; Thomas RL; Humes RA
    Pediatr Cardiol; 2003; 24(5):457-62. PubMed ID: 14627313
    [TBL] [Abstract][Full Text] [Related]  

  • 2. "Overestimation" of catheter gradients by Doppler ultrasound in patients with aortic stenosis: a predictable manifestation of pressure recovery.
    Baumgartner H; Stefenelli T; Niederberger J; Schima H; Maurer G
    J Am Coll Cardiol; 1999 May; 33(6):1655-61. PubMed ID: 10334438
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Correction of Doppler Gradients for Pressure Recovery Improves Agreement with Subsequent Catheterization Gradients in Congenital Aortic Stenosis.
    Schlingmann TR; Gauvreau K; Colan SD; Powell AJ
    J Am Soc Echocardiogr; 2015 Dec; 28(12):1410-7. PubMed ID: 26454341
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of simultaneous invasive and noninvasive measurements of pressure gradients in congenital aortic valve stenosis.
    Barker PC; Ensing G; Ludomirsky A; Bradley DJ; Lloyd TR; Rocchini AP
    J Am Soc Echocardiogr; 2002 Dec; 15(12):1496-502. PubMed ID: 12464918
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of Pressure Recovery on Pressure Gradients in Congenital Stenotic Outflow Lesions in Pediatric Patients-Clinical Implications of Lesion Severity and Geometry: A Simultaneous Doppler Echocardiography and Cardiac Catheter Correlative Study.
    Singh GK; Mowers KL; Marino C; Balzer D; Rao PS
    J Am Soc Echocardiogr; 2020 Feb; 33(2):207-217. PubMed ID: 31699474
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of the Doppler-derived pressure gradient in pediatric patients with aortic valvular stenosis: is the correction for pressure recovery necessary?
    Yamazawa H
    Hokkaido Igaku Zasshi; 2010 Jul; 85(4):225-31. PubMed ID: 20718206
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of aortic stenosis severity: role of contrast echocardiography in comparison with conventional echocardiography and cardiac catheterization.
    Almeida AG; Sargento L; Gabriel HM; da Costa JM; Morais J; Madeira F; David C; Oliveira J; da Cunha JC; Vagueiro MC
    Rev Port Cardiol; 2002 May; 21(5):555-72. PubMed ID: 12174519
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous Doppler/catheter measurements of pressure gradients in aortic valve disease: a correction to the Bernoulli equation based on velocity decay in the stenotic jet.
    VanAuker MD; Hla A; Meisner JS; Strom JA
    J Heart Valve Dis; 2000 Mar; 9(2):291-8. PubMed ID: 10772051
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Potential role of Reynolds number in resolving Doppler- and catheter-based transvalvular gradient discrepancies in aortic stenosis.
    Adams JC; Jiamsripong P; Belohlavek M; McMahon EM; Marupakula V; Heys J; Chaliki HP
    J Heart Valve Dis; 2011 Mar; 20(2):159-64. PubMed ID: 21560814
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Value of the continuous Doppler in the evaluation of gradients of aortic valvular stenosis in the adult].
    Mertl C; Isorni C; Rey JL; Choquet D; Duboisset M; Lesbre JP
    Arch Mal Coeur Vaiss; 1988 Jun; 81(6):735-42. PubMed ID: 3144945
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of severity of aortic stenosis by continuous wave Doppler echocardiography.
    Subramanyan R; Srinivasan M; Joy J; Tharakan J; Titus T; Venkitachalam CG; Balakrishnan KG
    Indian Heart J; 1990; 42(5):371-4. PubMed ID: 2086443
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Balloon valvuloplasty for congenital aortic valve stenosis in children].
    Wu L; Qi C; He L; Liu F; Lu Y; Huang G
    Zhonghua Er Ke Za Zhi; 2014 Sep; 52(9):699-702. PubMed ID: 25476434
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Correlation of pediatric echocardiographic Doppler and catheter-derived valvar aortic stenosis gradients and the influence of aortic regurgitation.
    Wright SB; Wienecke MM; Meyer KB; McKay CA; Wiles HB
    Am J Cardiol; 1996 Mar; 77(8):663-5. PubMed ID: 8610626
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Quantitative evaluation of aortic stenosis using continuous wave Doppler].
    Zhu WL
    Zhonghua Xin Xue Guan Bing Za Zhi; 1989 Feb; 17(1):7-9, 61. PubMed ID: 2766948
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Doppler-catheter discrepancies in patients with bileaflet mechanical prostheses or bioprostheses in the aortic valve position.
    Aljassim O; Svensson G; Houltz E; Bech-Hanssen O
    Am J Cardiol; 2008 Nov; 102(10):1383-9. PubMed ID: 18993160
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Insights into catheter/Doppler discrepancies in congenital aortic stenosis.
    Lemler MS; Valdes-Cruz LM; Shandas RS; Cape EG
    Am J Cardiol; 1999 May; 83(10):1447-50. PubMed ID: 10335760
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Continuous-wave Doppler echocardiographic assessment of severity of calcific aortic stenosis: a simultaneous Doppler-catheter correlative study in 100 adult patients.
    Currie PJ; Seward JB; Reeder GS; Vlietstra RE; Bresnahan DR; Bresnahan JF; Smith HC; Hagler DJ; Tajik AJ
    Circulation; 1985 Jun; 71(6):1162-9. PubMed ID: 3995710
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Instantaneous pressure gradient: a simultaneous Doppler and dual catheter correlative study.
    Currie PJ; Hagler DJ; Seward JB; Reeder GS; Fyfe DA; Bove AA; Tajik AJ
    J Am Coll Cardiol; 1986 Apr; 7(4):800-6. PubMed ID: 3958336
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Echocardiographic evaluation of pulmonary valve stenosis for valvuloplasty in children and adults].
    Nascimento R; Campelo M; Maciel J; Lourenço A; Carneiro M; Cunha D; Van-Zeller P
    Rev Port Cardiol; 1993 Feb; 12(2):141-50. PubMed ID: 8461154
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Echocardiographic follow-up of congenital aortic valvular stenosis.
    Eroglu AG; Babaoglu K; Saltik L; Oztunç F; Demir T; Ahunbay G; Guzeltas A; Cetin G
    Pediatr Cardiol; 2006; 27(6):713-9. PubMed ID: 17111293
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.