BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

210 related articles for article (PubMed ID: 14633348)

  • 1. Glucose sensors and the alternate site testing-like phenomenon: relationship between rapid blood glucose changes and glucose sensor signals.
    Koschinsky T; Jungheim K; Heinemann L
    Diabetes Technol Ther; 2003; 5(5):829-42. PubMed ID: 14633348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Rapid changes in postprandial blood glucose produce concentration differences at finger, forearm, and thigh sampling sites.
    Ellison JM; Stegmann JM; Colner SL; Michael RH; Sharma MK; Ervin KR; Horwitz DL
    Diabetes Care; 2002 Jun; 25(6):961-4. PubMed ID: 12032099
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Capillary blood sampling for self-monitoring of blood glucose.
    Yum SI; Roe J
    Diabetes Technol Ther; 1999; 1(1):29-37. PubMed ID: 11475301
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Accuracy of blood glucose concentration values outcome performed at various skin sites with personal glucose meters].
    Ruxer J; Mozdzan M; Ruxer M; Szabela DA; Markuszewski L; Loba J
    Pol Arch Med Wewn; 2005 May; 113(5):438-43. PubMed ID: 16479826
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Physiological influences on off-finger glucose testing.
    McGarraugh G; Price D; Schwartz S; Weinstein R
    Diabetes Technol Ther; 2001; 3(3):367-76. PubMed ID: 11762515
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Glucose monitoring at the thenar: evaluation of upper dermal blood glucose kinetics during rapid systemic blood glucose changes.
    Jungheim K; Koschinsky T
    Horm Metab Res; 2002 Jun; 34(6):325-9. PubMed ID: 12173073
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Palm glucose readings compared with fingertip readings under steady and dynamic glycemic conditions, using the OneTouch Ultra Blood Glucose Monitoring System.
    Kempe KC; Budd D; Stern M; Ellison JM; Saari LA; Adiletto CA; Olin B; Price DA; Horwitz DL
    Diabetes Technol Ther; 2005 Dec; 7(6):916-26. PubMed ID: 16386098
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Alternative site blood glucose testing: a multicenter study.
    Fedele D; Corsi A; Noacco C; Prisco F; Squatrito S; Torre E; Iafusco D; Errico MK; Toniato R; Nicolucci A; Franciosi M; De Berardis G; Neri L
    Diabetes Technol Ther; 2003; 5(6):983-9. PubMed ID: 14709201
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of alternate site testing--comparing arm and finger blood glucose results in glucose dynamic states.
    Lock JP; Szuts EZ; Malomo KJ; Anagnostopoulos A; Rao S
    Diabetes Technol Ther; 2002; 4(1):87-9. PubMed ID: 12017426
    [No Abstract]   [Full Text] [Related]  

  • 10. Cross-sectional investigation on the accuracy of alternate site glucose testing using the Soft-Sense glucose meter.
    Pfützner A; Hermanns N; Schröder S; Wegenstein M; Larbig M; Mondok A; Forst T; Haak T
    Swiss Med Wkly; 2002 Jun; 132(25-26):351-7. PubMed ID: 12422292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of CGMS during rapid blood glucose changes in patients with type 1 diabetes.
    Wilhelm B; Forst S; Weber MM; Larbig M; Pfützner A; Forst T
    Diabetes Technol Ther; 2006 Apr; 8(2):146-55. PubMed ID: 16734545
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effects of skin temperature and testing site on blood glucose measurements taken by a modern blood glucose monitoring device.
    Haupt A; Berg B; Paschen P; Dreyer M; Häring HU; Smedegaard J; Matthaei S
    Diabetes Technol Ther; 2005 Aug; 7(4):597-601. PubMed ID: 16120031
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Glucose monitoring at the arm: risky delays of hypoglycemia and hyperglycemia detection.
    Jungheim K; Koschinsky T
    Diabetes Care; 2002 Jun; 25(6):956-60. PubMed ID: 12032098
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of glucose levels in capillary blood samples obtained from a variety of body sites.
    Peled N; Wong D; Gwalani SL
    Diabetes Technol Ther; 2002; 4(1):35-44; discussion 45-7. PubMed ID: 12017418
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of glucose levels in dermal interstitial fluid and finger capillary blood.
    Stout PJ; Peled N; Erickson BJ; Hilgers ME; Racchini JR; Hoegh TB
    Diabetes Technol Ther; 2001; 3(1):81-90. PubMed ID: 11469711
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of lancets for pain perception and capillary blood volume for glucose monitoring.
    Warunek D; Stankovic AK
    Clin Lab Sci; 2008; 21(4):215-8. PubMed ID: 19174981
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Capillary and venous blood glucose concentrations measured during intravenous insulin and glucose infusion: a comparison of steady and dynamic states.
    Kempe K; Price D; Ellison J; Marhoul J; Morrow L; Win K; Kuschma K; Hompesch M
    Diabetes Technol Ther; 2009 Oct; 11(10):669-74. PubMed ID: 19821760
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Modeling Plasma-to-Interstitium Glucose Kinetics from Multitracer Plasma and Microdialysis Data.
    Schiavon M; Dalla Man C; Dube S; Slama M; Kudva YC; Peyser T; Basu A; Basu R; Cobelli C
    Diabetes Technol Ther; 2015 Nov; 17(11):825-31. PubMed ID: 26313215
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Continuous glucose monitoring with glucose sensors: calibration and assessment criteria.
    Lodwig V; Heinemann L;
    Diabetes Technol Ther; 2003; 5(4):572-86. PubMed ID: 14511412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Whole-blood glucose testing at alternate sites: glucose values and hematocrit of capillary blood drawn from fingertip and forearm.
    Lock JP; Szuts EZ; Malomo KJ; Anagnostopoulos A
    Diabetes Care; 2002 Feb; 25(2):337-41. PubMed ID: 11815506
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.