These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Adsorption of human plasma proteins to modified titanium surfaces. Sela MN; Badihi L; Rosen G; Steinberg D; Kohavi D Clin Oral Implants Res; 2007 Oct; 18(5):630-8. PubMed ID: 17484735 [TBL] [Abstract][Full Text] [Related]
3. Adsorption/desorption phenomena on pure and Teflon AF-coated titania surfaces studied by dynamic contact angle analysis. Rupp F; Axmann D; Ziegler C; Geis-Gerstorfer J J Biomed Mater Res; 2002 Dec; 62(4):567-78. PubMed ID: 12221705 [TBL] [Abstract][Full Text] [Related]
4. Enhancing surface free energy and hydrophilicity through chemical modification of microstructured titanium implant surfaces. Rupp F; Scheideler L; Olshanska N; de Wild M; Wieland M; Geis-Gerstorfer J J Biomed Mater Res A; 2006 Feb; 76(2):323-34. PubMed ID: 16270344 [TBL] [Abstract][Full Text] [Related]
5. Enhancement of surface wettability via the modification of microtextured titanium implant surfaces with polyelectrolytes. Park JH; Schwartz Z; Olivares-Navarrete R; Boyan BD; Tannenbaum R Langmuir; 2011 May; 27(10):5976-85. PubMed ID: 21513319 [TBL] [Abstract][Full Text] [Related]
6. UV-A and UV-C light induced hydrophilization of dental implants. Al Qahtani MS; Wu Y; Spintzyk S; Krieg P; Killinger A; Schweizer E; Stephan I; Scheideler L; Geis-Gerstorfer J; Rupp F Dent Mater; 2015 Aug; 31(8):e157-67. PubMed ID: 25981907 [TBL] [Abstract][Full Text] [Related]
7. Contact angle, protein adsorption and osteoblast precursor cell attachment to chitosan coatings bonded to titanium. Bumgardner JD; Wiser R; Elder SH; Jouett R; Yang Y; Ong JL J Biomater Sci Polym Ed; 2003; 14(12):1401-9. PubMed ID: 14870943 [TBL] [Abstract][Full Text] [Related]
8. Novel functionalization of Ti-V alloy and Ti-II using atomic layer deposition for improved surface wettability. Patel S; Butt A; Tao Q; Rossero A JI; Royhman D; Sukotjo C; Takoudis CG Colloids Surf B Biointerfaces; 2014 Mar; 115():280-5. PubMed ID: 24384144 [TBL] [Abstract][Full Text] [Related]
9. Comparison of Roughness, Wettability, and SEM Features between Sandblasted Acid-Etched and Oxidized Titanium Dental Implants. Chhabra K; Rajasekar A J Long Term Eff Med Implants; 2024; 34(4):57-63. PubMed ID: 38842233 [TBL] [Abstract][Full Text] [Related]
10. Thermal and chemical modification of titanium-aluminum-vanadium implant materials: effects on surface properties, glycoprotein adsorption, and MG63 cell attachment. MacDonald DE; Rapuano BE; Deo N; Stranick M; Somasundaran P; Boskey AL Biomaterials; 2004 Jul; 25(16):3135-46. PubMed ID: 14980408 [TBL] [Abstract][Full Text] [Related]
11. Roughness and wettability of titanium implant surfaces modify the salivary pellicle composition. Martínez-Hernández M; Hannig M; García-Pérez VI; Olivares-Navarrete R; Fecher-Trost C; Almaguer-Flores A J Biomed Mater Res B Appl Biomater; 2021 Jul; 109(7):1017-1028. PubMed ID: 33252193 [TBL] [Abstract][Full Text] [Related]
12. Wettability studies of topologically distinct titanium surfaces. Kulkarni M; Patil-Sen Y; Junkar I; Kulkarni CV; Lorenzetti M; Iglič A Colloids Surf B Biointerfaces; 2015 May; 129():47-53. PubMed ID: 25819365 [TBL] [Abstract][Full Text] [Related]
13. Bacterial attachment on titanium surfaces is dependent on topography and chemical changes induced by nonthermal atmospheric pressure plasma. Jeong WS; Kwon JS; Lee JH; Uhm SH; Ha Choi E; Kim KM Biomed Mater; 2017 Jul; 12(4):045015. PubMed ID: 28746053 [TBL] [Abstract][Full Text] [Related]
14. Surface analysis of titanium biological modification with glow discharge. Chang YC; Feng SW; Huang HM; Teng NC; Lin CT; Lin HK; Wang PD; Chang WJ Clin Implant Dent Relat Res; 2015 Jun; 17(3):469-75. PubMed ID: 23981288 [TBL] [Abstract][Full Text] [Related]
15. Influence of Surface Contaminants and Hydrocarbon Pellicle on the Results of Wettability Measurements of Titanium. Kido D; Komatsu K; Suzumura T; Matsuura T; Cheng J; Kim J; Park W; Ogawa T Int J Mol Sci; 2023 Sep; 24(19):. PubMed ID: 37834133 [TBL] [Abstract][Full Text] [Related]
16. Relevant aspects in the surface properties in titanium dental implants for the cellular viability. Velasco-Ortega E; Alfonso-Rodríguez CA; Monsalve-Guil L; España-López A; Jiménez-Guerra A; Garzón I; Alaminos M; Gil FJ Mater Sci Eng C Mater Biol Appl; 2016 Jul; 64():1-10. PubMed ID: 27127022 [TBL] [Abstract][Full Text] [Related]
17. Modification of titanium alloys surface properties by plasma electrolytic oxidation (PEO) and influence on biological response. Echeverry-Rendón M; Galvis O; Aguirre R; Robledo S; Castaño JG; Echeverría F J Mater Sci Mater Med; 2017 Sep; 28(11):169. PubMed ID: 28956201 [TBL] [Abstract][Full Text] [Related]
18. Wettability versus electrostatic forces in fibronectin and albumin adsorption to titanium surfaces. Kohavi D; Badihi Hauslich L; Rosen G; Steinberg D; Sela MN Clin Oral Implants Res; 2013 Sep; 24(9):1002-8. PubMed ID: 22697368 [TBL] [Abstract][Full Text] [Related]
19. Age-dependent degradation of the protein adsorption capacity of titanium. Hori N; Att W; Ueno T; Sato N; Yamada M; Saruwatari L; Suzuki T; Ogawa T J Dent Res; 2009 Jul; 88(7):663-7. PubMed ID: 19641155 [TBL] [Abstract][Full Text] [Related]
20. Er,Cr:YSGG laser surface treatment of gamma titanium aluminide: Scanning electron microscopy-energy-dispersive X-ray spectrometer analysis, wettability and Koopaie M; Kia Darbandsari A; Hakimiha N; Kolahdooz S Proc Inst Mech Eng H; 2020 Aug; 234(8):769-783. PubMed ID: 32419598 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]