These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 14649358)

  • 1. Results of plate fixation of type 1b olecranon fractures in 24 horses.
    Swor TM; Watkins JP; Bahr A; Honnas CM
    Equine Vet J; 2003 Nov; 35(7):670-5. PubMed ID: 14649358
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Results of plate fixation of type 5 olecranon fractures in 20 horses.
    Swor TM; Watkins JR; Bahr A; Epstein KL; Honnas CM
    Equine Vet J; 2006 Jan; 38(1):30-4. PubMed ID: 16411583
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Use of locking compression plates in ulnar fractures of 18 horses.
    Jacobs CC; Levine DG; Richardson DW
    Vet Surg; 2017 Feb; 46(2):242-248. PubMed ID: 28146292
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Retrospective analysis of 29 fractures of the olecranon process of the equine ulna.
    Donecker JM; Bramlage LR; Gabel AA
    J Am Vet Med Assoc; 1984 Jul; 185(2):183-9. PubMed ID: 6746387
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The surgical treatment of fractures of the olecranon in the horse.
    Denny HR
    Equine Vet J; 1976 Jan; 8(1):20-5. PubMed ID: 1253776
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Use of tension band wires in horses with fractures of the ulna: 22 cases (1980-1992).
    Martin F; Richardson DW; Nunamaker DM; Ross MW; Orsini JA
    J Am Vet Med Assoc; 1995 Oct; 207(8):1085-9. PubMed ID: 7559052
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Stabilization of Olecranon Fractures by Tension Band Wiring or Plate Osteosynthesis: A Retrospective Study of 41 Cases.
    Fournet A; Boursier JF; Corbeau S; Decambron A; Viateau V; Fayolle P; Bedu AS; Leperlier D; Manassero M
    Vet Comp Orthop Traumatol; 2018 Jan; 31(1):53-61. PubMed ID: 29325193
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comminuted olecranon fractures: biomechanical testing of locked versus minifragment non-locked plate fixation.
    Wellman DS; Tucker SM; Baxter JR; Pardee NC; Lazaro LE; Smith CS; Lorich DG; Helfet DL
    Arch Orthop Trauma Surg; 2017 Sep; 137(9):1173-1179. PubMed ID: 28634743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical use of the locking compression plate (LCP) in horses: a retrospective study of 31 cases (2004-2006).
    Levine DG; Richardson DW
    Equine Vet J; 2007 Sep; 39(5):401-6. PubMed ID: 17910263
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of three methods of ulnar fixation in horses.
    Hanson PD; Hartwig H; Markel MD
    Vet Surg; 1997; 26(3):165-71. PubMed ID: 9150553
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Outcome after olecranon fracture repair: Does construct type matter?
    DelSole EM; Pean CA; Tejwani NC; Egol KA
    Eur J Orthop Surg Traumatol; 2016 Feb; 26(2):153-9. PubMed ID: 26573486
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Racing prognosis of horses following surgically repaired olecranon fractures.
    Janicek JC; Rodgerson DH; Hunt RJ; Spirito MA; Thorpe PE; Tessman RK
    Can Vet J; 2006 Mar; 47(3):241-5. PubMed ID: 16604980
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Radiographic and scintigraphic imaging of a proximal radial physeal injury in a young horse induced by olecranon fracture repair.
    Metcalf MR; Tate LP; Sellett LC; Henry M
    Equine Vet J; 1990 Jan; 22(1):56-9. PubMed ID: 2298193
    [No Abstract]   [Full Text] [Related]  

  • 14. Repair of physeal fractures of the tuber olecranon in the horse, using a tension band method.
    Monin T
    J Am Vet Med Assoc; 1978 Feb; 172(3):287-90. PubMed ID: 621174
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The application of central tension plate with sharp hook in the treatment of intra-articular olecranon fracture.
    Chen W; Zhang Q; Hou Z; Zhang Y
    BMC Musculoskelet Disord; 2013 Oct; 14():308. PubMed ID: 24161080
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Treatment of type 2 and 4 olecranon fractures with locking compression plate osteosynthesis in horses: a prospective study (2002-2008).
    Jackson M; Kummer M; Auer J; Hagen R; Fuerst A
    Vet Comp Orthop Traumatol; 2011; 24(1):57-61. PubMed ID: 21103649
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.
    Gruszka D; Arand C; Greenfield J; Nowak TE; Kuechle R; Kuhn S; Rommens PM
    Arch Orthop Trauma Surg; 2017 Dec; 137(12):1651-1658. PubMed ID: 28864862
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical Evaluation of Standard Versus Extended Proximal Fixation Olecranon Plates for Fixation of Olecranon Fractures.
    Boden AL; Daly CA; Dalwadi PP; Boden SA; Hutton WC; Muppavarapu RC; Gottschalk MB
    Hand (N Y); 2019 Jul; 14(4):554-559. PubMed ID: 29319350
    [No Abstract]   [Full Text] [Related]  

  • 19. Critical analysis of olecranon fracture management by pre-contoured locking plates.
    Niglis L; Bonnomet F; Schenck B; Brinkert D; Di Marco A; Adam P; Ehlinger M
    Orthop Traumatol Surg Res; 2015 Apr; 101(2):201-7. PubMed ID: 25736196
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [EFFECTIVENESS OF SHARP TEETH HOOK PLATE FOR TREATMENT OF OLECRANON FRACTURES].
    Yin Q; Gu S; Liu J; Wu Y; Lu Y; Ma Y; Sheng Y
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Sep; 30(9):1094-1097. PubMed ID: 29786362
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.