BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

150 related articles for article (PubMed ID: 14650998)

  • 1. [The measurement of retentive force of laser-melted and cast post-keepers of Magfit magnetic attachments].
    Yang L; Du L; Lin Y
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Oct; 21(5):386-8. PubMed ID: 14650998
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparative study of the surface characteristics, microstructure, and magnetic retentive forces of laser-welded dowel-keepers and cast dowel-keepers for use with magnetic attachments.
    Chao Y; Du L; Yang L
    J Prosthet Dent; 2005 May; 93(5):473-7. PubMed ID: 15867758
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [A study on microstructures and heat reaction zone of laser-melted and cast post-keepers].
    Du L; Yang L; Xu C
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Oct; 21(5):383-5. PubMed ID: 14650997
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [The measurement of retentive forces in mandibular complete overdenture with Magfit magnetic attachments].
    Du L; Xu C; Chao Y
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2003 Oct; 21(5):366-8. PubMed ID: 14650991
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Measurements of the flux densities of static magnetic fields generated by two types of dental magnetic attachments and their retentive forces].
    Xu C; Chao YL; Du L; Yang L
    Sichuan Da Xue Xue Bao Yi Xue Ban; 2004 May; 35(3):412-5. PubMed ID: 15181852
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Effect of burn-out temperature on magnetic keepers in cast noble metal alloy posts.
    Pow EH; Chan KH; Luk HW; Dias AP; McMillan AS
    J Prosthet Dent; 2009 Jan; 101(1):66-72. PubMed ID: 19105993
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Installing magnetic keepers using LASER welding.
    Ishikawa M; Kashiwabara T; Ishida O; Ichikawa T
    J Prosthodont; 2002 Mar; 11(1):49-52. PubMed ID: 11935511
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A quality assessment of the casting process on magnetic keepers.
    Luk HW; Pow EH; Dias AP
    J Prosthodont; 2007; 16(4):249-54. PubMed ID: 17451482
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of core diameter and surface treatment on the retention of resin composite cores to prefabricated endodontic posts.
    Artopoulou II; O'Keefe KL; Powers JM
    J Prosthodont; 2006; 15(3):172-9. PubMed ID: 16681499
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of sterilization on the retention properties of magnetic attachments for dental implants.
    Boeckler AF; Morton D; Ehring C; Setz JM
    Clin Oral Implants Res; 2009 Nov; 20(11):1206-11. PubMed ID: 19832767
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Corrosion of dental magnet attachments for removable prostheses on teeth and implants.
    Boeckler AF; Ehring C; Morton D; Geis-Gerstorfer J; Setz JM
    J Prosthodont; 2009 Jun; 18(4):301-8. PubMed ID: 19210309
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An alternative section method for casting and posterior laser welding of metallic frameworks for an implant-supported prosthesis.
    de Aguiar FA; Tiossi R; Rodrigues RC; Mattos Mde G; Ribeiro RF
    J Prosthodont; 2009 Apr; 18(3):230-4. PubMed ID: 19141050
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Effects of laser welding on bond of porcelain fused cast pure titanium].
    Zhu JF; He HM; Gao B; Wang ZY
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2006 Apr; 41(4):236-9. PubMed ID: 16784592
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of the passivity between cast alloy and laser-welded titanium overdenture bars.
    Paiva J; Givan DA; Broome JC; Lemons JE; McCracken MS
    J Prosthodont; 2009 Dec; 18(8):656-62. PubMed ID: 19682220
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ring liner and burn-out temperature affect the clinical time required to fit a cast post.
    Otun A; Lee H; Geminiani A; Shirakura A; Ercoli C; Feng C
    J Prosthet Dent; 2009 Oct; 102(4):224-8. PubMed ID: 19782824
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Mechanical properties of magnetic attachments for removable prostheses on teeth and implants.
    Boeckler AF; Morton D; Ehring C; Setz JM
    J Prosthodont; 2008 Dec; 17(8):608-15. PubMed ID: 18761583
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative analysis of the fit of 3-unit implant-supported frameworks cast in nickel-chromium and cobalt-chromium alloys and commercially pure titanium after casting, laser welding, and simulated porcelain firings.
    Tiossi R; Rodrigues RC; de Mattos Mda G; Ribeiro RF
    Int J Prosthodont; 2008; 21(2):121-3. PubMed ID: 18546764
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tensile bond strength of cast commercially pure titanium and cast gold-alloy posts and cores cemented with two luting agents.
    Menani LR; Ribeiro RF; Antunes RP
    J Prosthet Dent; 2008 Feb; 99(2):141-7. PubMed ID: 18262015
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dental magnetic attachment: toward third generation devices.
    Tegawa Y; Kinouchi Y
    IEEE Trans Biomed Eng; 2008 Mar; 55(3):1185-90. PubMed ID: 18334412
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparative study of retentive anchor systems for overdentures.
    Svetlize CA; Bodereau EF
    Quintessence Int; 2004 Jun; 35(6):443-8. PubMed ID: 15202589
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.