398 related articles for article (PubMed ID: 14652394)
1. Polyethylene wear and acetabular component orientation.
Patil S; Bergula A; Chen PC; Colwell CW; D'Lima DD
J Bone Joint Surg Am; 2003; 85-A Suppl 4():56-63. PubMed ID: 14652394
[TBL] [Abstract][Full Text] [Related]
2. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing.
Korduba LA; Essner A; Pivec R; Lancin P; Mont MA; Wang A; Delanois RE
Am J Orthop (Belle Mead NJ); 2014 Oct; 43(10):466-71. PubMed ID: 25303445
[TBL] [Abstract][Full Text] [Related]
3. Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.
Tian JL; Sun L; Hu RY; Han W; Tian XB
Orthop Surg; 2017 May; 9(2):186-190. PubMed ID: 28557297
[TBL] [Abstract][Full Text] [Related]
4. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up.
Teeter MG; Lanting BA; Naudie DD; McCalden RW; Howard JL; MacDonald SJ
Bone Joint J; 2018 Jul; 100-B(7):891-897. PubMed ID: 29954202
[TBL] [Abstract][Full Text] [Related]
5. Wear Rates of Larger-Diameter Cross-Linked Polyethylene at 5 to 13 Years: Does Liner Thickness or Component Position Matter?
Haw JG; Battenberg AK; Huang DT; Schmalzried TP
J Arthroplasty; 2017 Apr; 32(4):1381-1386. PubMed ID: 28007372
[TBL] [Abstract][Full Text] [Related]
6. Femoral-Acetabular Mating: The Effect of Femoral and Combined Anteversion on Cross-Linked Polyethylene Wear.
Mayeda BF; Haw JG; Battenberg AK; Schmalzried TP
J Arthroplasty; 2018 Oct; 33(10):3320-3324. PubMed ID: 29970327
[TBL] [Abstract][Full Text] [Related]
7. Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years.
Crowther JD; Lachiewicz PF
J Bone Joint Surg Am; 2002 May; 84(5):729-35. PubMed ID: 12004013
[TBL] [Abstract][Full Text] [Related]
8. Effects of acetabular abduction on cup wear rates in total hip arthroplasty.
Del Schutte H; Lipman AJ; Bannar SM; Livermore JT; Ilstrup D; Morrey BF
J Arthroplasty; 1998 Sep; 13(6):621-6. PubMed ID: 9741436
[TBL] [Abstract][Full Text] [Related]
9. Clinical biomechanics of wear in total hip arthroplasty.
Callaghan JJ; Pedersen DR; Johnston RC; Brown TD
Iowa Orthop J; 2003; 23():1-12. PubMed ID: 14575243
[TBL] [Abstract][Full Text] [Related]
10. The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups--finite element simulations and experimental tests.
Korhonen RK; Koistinen A; Konttinen YT; Santavirta SS; Lappalainen R
Biomed Eng Online; 2005 May; 4():32. PubMed ID: 15904521
[TBL] [Abstract][Full Text] [Related]
11. Radiographic and clinical analysis of cementless acetabular fixation in total hip arthroplasty.
Zhang H; Pei FX; Yang J; Shen B; Shi R
Chin J Traumatol; 2005 Oct; 8(5):263-8. PubMed ID: 16176755
[TBL] [Abstract][Full Text] [Related]
12. Relation between vertical orientation and stability of acetabular component in the dysplastic hip simulated by nonlinear three-dimensional finite element method.
Oki H; Ando M; Omori H; Okumura Y; Negoro K; Uchida K; Baba H
Artif Organs; 2004 Nov; 28(11):1050-4. PubMed ID: 15504121
[TBL] [Abstract][Full Text] [Related]
13. Finite element simulation of early creep and wear in total hip arthroplasty.
Bevill SL; Bevill GR; Penmetsa JR; Petrella AJ; Rullkoetter PJ
J Biomech; 2005 Dec; 38(12):2365-74. PubMed ID: 16214484
[TBL] [Abstract][Full Text] [Related]
14. [Comparative study on association between femoral head size and linear wear rate of highly cross-linked polyethylene liner].
Guo S; Sun J; Zha G; Wei S; Lu Q
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1333-7. PubMed ID: 25639045
[TBL] [Abstract][Full Text] [Related]
15. Influence of polyethylene creep behavior on wear in total hip arthroplasty.
Penmetsa JR; Laz PJ; Petrella AJ; Rullkoetter PJ
J Orthop Res; 2006 Mar; 24(3):422-7. PubMed ID: 16479600
[TBL] [Abstract][Full Text] [Related]
16. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios.
D'Lima DD; Urquhart AG; Buehler KO; Walker RH; Colwell CW
J Bone Joint Surg Am; 2000 Mar; 82(3):315-21. PubMed ID: 10724224
[TBL] [Abstract][Full Text] [Related]
17. Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size.
Lachiewicz PF; Soileau ES; Martell JM
Clin Orthop Relat Res; 2016 Feb; 474(2):365-71. PubMed ID: 25903943
[TBL] [Abstract][Full Text] [Related]
18. Fixation and wear with a contemporary acetabular component and cross-linked polyethylene at minimum 10-year follow-up.
Bedard NA; Callaghan JJ; Stefl MD; Willman TJ; Liu SS; Goetz DD
J Arthroplasty; 2014 Oct; 29(10):1961-9. PubMed ID: 24939638
[TBL] [Abstract][Full Text] [Related]
19. [Correlations between polyethylene wear direction and other influencing factors in total hip arthroplasty].
Lan T; Xiao J; Shi Z
Zhonghua Yi Xue Za Zhi; 2014 Nov; 94(43):3416-20. PubMed ID: 25622673
[TBL] [Abstract][Full Text] [Related]
20. Revision Total Hip Arthroplasty with Retained Acetabular Component.
Adelani MA; Mall NA; Nyazee H; Clohisy JC; Barrack RL; Nunley RM
J Bone Joint Surg Am; 2014 Jun; 96(12):1015-1020. PubMed ID: 24951737
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]