These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
58 related articles for article (PubMed ID: 1465334)
1. [Fundamental study of helical scanning CT--evaluation of spatial resolution in the longitudinal axis]. Anno H; Katada K; Tsujioka K; Ida Y; Ohashi I; Takeuchi A; Koga S Nihon Igaku Hoshasen Gakkai Zasshi; 1992 Nov; 52(11):1540-4. PubMed ID: 1465334 [TBL] [Abstract][Full Text] [Related]
9. [Helical CT for lung-cancer screening: third report: fundamental study for ultralow-dose CT by application of small tube current and filter]. Itoh S; Koyama S; Tusaka M; Maekoshi H; Satake H; Ishigaki T Nihon Igaku Hoshasen Gakkai Zasshi; 1996 Nov; 56(13):961-6. PubMed ID: 8969060 [TBL] [Abstract][Full Text] [Related]
10. Image-guided radiotherapy using a mobile kilovoltage x-ray device. Sorensen SP; Chow PE; Kriminski S; Medin PM; Solberg TD Med Dosim; 2006; 31(1):40-50. PubMed ID: 16551528 [TBL] [Abstract][Full Text] [Related]
11. [Algorithms of CT value correction for reconstructing a radiotherapy simulation image through axial CT images]. Ogino T; Egawa S Nihon Igaku Hoshasen Gakkai Zasshi; 1991 Apr; 51(4):406-14. PubMed ID: 2067942 [TBL] [Abstract][Full Text] [Related]
12. [Clinical usefulness of helical-scanning CT for the evaluation of arteriosclerotic carotid lesions]. Nomura M; Katada K; Anno H; Ogura Y; Takeshita G; Kato R; Osawa H; Yamamoto H; Kanno T; Koga S Nihon Igaku Hoshasen Gakkai Zasshi; 1995 Oct; 55(12):878-84. PubMed ID: 8539107 [TBL] [Abstract][Full Text] [Related]
13. [Improvement of longitudinal resolution by deblurring technique in helical CT of the head and neck]. Sakai O; Shen Y; Kimura F; Takata Y Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Mar; 57(4):211-4. PubMed ID: 9125878 [TBL] [Abstract][Full Text] [Related]
14. Detection of nodular lesions in the lung using helical computed tomography: comparison of fast couch speed technique with conventional computed tomography. Mori K; Sasagawa M; Moriyama N Jpn J Clin Oncol; 1994 Oct; 24(5):252-7. PubMed ID: 7967104 [TBL] [Abstract][Full Text] [Related]
15. Short communication: helical computed tomography: where is the cut? Horrocks JA; Speller RD Br J Radiol; 1994 Jan; 67(793):107-11. PubMed ID: 8298865 [TBL] [Abstract][Full Text] [Related]
17. [Report on the 89th Scientific Assembly and Annual Meeting of the Radiological Society of North America--evaluation of spatial resolution and contrast resolution for MPR diagnosis]. Fujii K Nihon Hoshasen Gijutsu Gakkai Zasshi; 2004 Dec; 60(12):1668-9. PubMed ID: 15614215 [TBL] [Abstract][Full Text] [Related]
18. Factors affecting the measurement of size and CT number in computed tomography. Baxter BS; Sorenson JA Invest Radiol; 1981; 16(4):337-41. PubMed ID: 7275548 [TBL] [Abstract][Full Text] [Related]
19. Measurement of CT section thickness by using the partial volume effect. Shiraishi J; Tsuda K; Inoue Y; Onoyama Y Radiology; 1992 Sep; 184(3):870-2. PubMed ID: 1509082 [TBL] [Abstract][Full Text] [Related]