These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
297 related articles for article (PubMed ID: 14656902)
1. Liquid chromatography-tandem mass spectrometry assay for simultaneous measurement of estradiol and estrone in human plasma. Nelson RE; Grebe SK; OKane DJ; Singh RJ Clin Chem; 2004 Feb; 50(2):373-84. PubMed ID: 14656902 [TBL] [Abstract][Full Text] [Related]
2. Simultaneous quantitation of endogenous estrone, 17β-estradiol, and estriol in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry for clinical laboratory applications. Zhang Q; Han L; Wang J; Lin H; Ke P; Zhuang J; Huang X Anal Bioanal Chem; 2017 Apr; 409(10):2627-2638. PubMed ID: 28224243 [TBL] [Abstract][Full Text] [Related]
3. Trace level quantification of deuterated 17beta-estradiol and estrone in ovariectomized mouse plasma and brain using liquid chromatography/tandem mass spectrometry following dansylation reaction. Xia YQ; Chang SW; Patel S; Bakhtiar R; Karanam B; Evans DC Rapid Commun Mass Spectrom; 2004; 18(14):1621-8. PubMed ID: 15282788 [TBL] [Abstract][Full Text] [Related]
4. Sex-specific Estrogen Levels and Reference Intervals from Infancy to Late Adulthood Determined by LC-MS/MS. Frederiksen H; Johannsen TH; Andersen SE; Albrethsen J; Landersoe SK; Petersen JH; Andersen AN; Vestergaard ET; Schorring ME; Linneberg A; Main KM; Andersson AM; Juul A J Clin Endocrinol Metab; 2020 Mar; 105(3):754-68. PubMed ID: 31720688 [TBL] [Abstract][Full Text] [Related]
5. LC-MS/MS coupled with immunoaffinity extraction for determination of estrone, 17beta-estradiol and estrone 3-sulfate in human plasma. Hosogi J; Tanaka H; Fujita K; Kuwabara T; Ikegawa S; Kobayashi N; Mano N; Goto J J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Jan; 878(2):222-7. PubMed ID: 19700374 [TBL] [Abstract][Full Text] [Related]
6. Simultaneous analysis of E1 and E2 by LC-MS/MS in healthy volunteers: estimation of reference intervals and comparison with a conventional E2 immunoassay. van Winden LJ; Kok M; Acda M; Dezentje V; Linn S; Shi RZ; van Rossum HH J Chromatogr B Analyt Technol Biomed Life Sci; 2021 Jul; 1178():122563. PubMed ID: 34224962 [TBL] [Abstract][Full Text] [Related]
7. Sensitive routine liquid chromatography-tandem mass spectrometry method for serum estradiol and estrone without derivatization. Pauwels S; Antonio L; Jans I; Lintermans A; Neven P; Claessens F; Decallonne B; Billen J; Vanderschueren D; Vermeersch P Anal Bioanal Chem; 2013 Oct; 405(26):8569-77. PubMed ID: 23892882 [TBL] [Abstract][Full Text] [Related]
8. An optimised, highly sensitive radioimmunoassay for the simultaneous measurement of estrone, estradiol and estrone sulfate in the ultra-low range in human plasma samples. Geisler J; Ekse D; Helle H; Duong NK; Lønning PE J Steroid Biochem Mol Biol; 2008 Mar; 109(1-2):90-5. PubMed ID: 18242079 [TBL] [Abstract][Full Text] [Related]
9. Effects of letrozole on serum estradiol and estrone in postmenopausal breast cancer patients and tolerability of treatment: a prospective trial using a highly sensitive LC-MS/MS (liquid chromatography-tandem mass spectrometry) method for estrogen measurement. Faltinová M; Vehmanen L; Lyytinen H; Haanpää M; Hämäläinen E; Tiitinen A; Blomqvist C; Mattson J Breast Cancer Res Treat; 2023 Oct; 201(3):425-435. PubMed ID: 37491651 [TBL] [Abstract][Full Text] [Related]
10. Development and validation of a liquid chromatography coupled to mass spectrometer (LC-MS) method for the simultaneous quantification of estrone-3-sulfate, progesterone, estrone and estradiol in serum of mares and American bisons. Dufour P; Courtois J; Seynaeve Y; Peeters S; Le Goff C; Cavalier E; Ponthier J Res Vet Sci; 2021 May; 136():343-350. PubMed ID: 33770524 [TBL] [Abstract][Full Text] [Related]
11. Derivatization of estrogens enhances specificity and sensitivity of analysis of human plasma and serum by liquid chromatography tandem mass spectrometry. Faqehi AMM; Cobice DF; Naredo G; Mak TCS; Upreti R; Gibb FW; Beckett GJ; Walker BR; Homer NZM; Andrew R Talanta; 2016 May; 151():148-156. PubMed ID: 26946022 [TBL] [Abstract][Full Text] [Related]
12. Development of a highly sensitive method for the quantification of estrone and estradiol in serum by liquid chromatography tandem mass spectrometry without derivatization. Fiers T; Casetta B; Bernaert B; Vandersypt E; Debock M; Kaufman JM J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Apr; 893-894():57-62. PubMed ID: 22429877 [TBL] [Abstract][Full Text] [Related]
13. High-sensitivity quantification of serum androstenedione, testosterone, dihydrotestosterone, estrone and estradiol by gas chromatography-tandem mass spectrometry with sex- and puberty-specific reference intervals. Ankarberg-Lindgren C; Dahlgren J; Andersson MX J Steroid Biochem Mol Biol; 2018 Oct; 183():116-124. PubMed ID: 29894754 [TBL] [Abstract][Full Text] [Related]
14. Female and male serum reference intervals for challenging sex and precursor steroids by liquid chromatography - tandem mass spectrometry. Mezzullo M; Pelusi C; Fazzini A; Repaci A; Di Dalmazi G; Gambineri A; Pagotto U; Fanelli F J Steroid Biochem Mol Biol; 2020 Mar; 197():105538. PubMed ID: 31734493 [TBL] [Abstract][Full Text] [Related]
15. A rapid direct assay for the routine measurement of oestradiol and oestrone by liquid chromatography tandem mass spectrometry. Owen LJ; Wu FC; Keevil BG Ann Clin Biochem; 2014 May; 51(Pt 3):360-7. PubMed ID: 24084694 [TBL] [Abstract][Full Text] [Related]
16. High-sensitivity tandem mass spectrometry assay for serum estrone and estradiol. Kushnir MM; Rockwood AL; Bergquist J; Varshavsky M; Roberts WL; Yue B; Bunker AM; Meikle AW Am J Clin Pathol; 2008 Apr; 129(4):530-9. PubMed ID: 18343779 [TBL] [Abstract][Full Text] [Related]
17. Simultaneous Quantitation of Estradiol and Estrone in Serum Using Liquid Chromatography Mass Spectrometry. Riley CP; Mathieu RE; Wiley C Methods Mol Biol; 2016; 1378():87-97. PubMed ID: 26602121 [TBL] [Abstract][Full Text] [Related]
18. Measurement of estradiol, estrone, and testosterone in postmenopausal human serum by isotope dilution liquid chromatography tandem mass spectrometry without derivatization. Wooding KM; Hankin JA; Johnson CA; Chosich JD; Baek SW; Bradford AP; Murphy RC; Santoro N Steroids; 2015 Apr; 96():89-94. PubMed ID: 25617740 [TBL] [Abstract][Full Text] [Related]
19. A sensitive, simple and robust LC-MS/MS method for the simultaneous quantification of seven androgen- and estrogen-related steroids in postmenopausal serum. Ke Y; Bertin J; Gonthier R; Simard JN; Labrie F J Steroid Biochem Mol Biol; 2014 Oct; 144 Pt B():523-34. PubMed ID: 25158021 [TBL] [Abstract][Full Text] [Related]
20. Simultaneous quantification of four native estrogen hormones at trace levels in human cerebrospinal fluid using liquid chromatography-tandem mass spectrometry. Nguyen HP; Li L; Gatson JW; Maass D; Wigginton JG; Simpkins JW; Schug KA J Pharm Biomed Anal; 2011 Mar; 54(4):830-7. PubMed ID: 21145681 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]