BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 14659446)

  • 1. Validation of a simple liquid chromatography-tandem mass spectrometric method for the determination of propiverine hydrochloride and its N-oxide metabolite in human plasma.
    Komoto I; Yoshida K; Matsushima E; Yamashita K; Aikawa T; Akashi S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Jan; 799(1):141-7. PubMed ID: 14659446
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Determination of propiverine hydrochloride in human plasma by high performance liquid chromatography-tandem mass spectrometry: application to the pharmacokinetic study of a sustained release formulation.
    Huang M; Tian Y; Zhang Z; Zhang H; Lin H
    Arzneimittelforschung; 2011; 61(9):494-501. PubMed ID: 22029224
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Quantification of propiverine by liquid chromatography/electrospray tandem mass spectrometry: application to a bioequivalence study of two formulations in healthy subjects.
    Cho SH; Lee HW; Im HT; Park WS; Baek M; Lee KT
    J Pharm Biomed Anal; 2005 Sep; 39(3-4):670-6. PubMed ID: 15936164
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Determination of propiverine and its metabolites in rat samples by liquid chromatography-tandem mass spectrometry.
    Oertel R; Kilian B; Siegmund W; Kirch W
    J Chromatogr A; 2007 May; 1149(1):121-6. PubMed ID: 17141252
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determination of tiropramide in human plasma by liquid chromatography-tandem mass spectrometry.
    Lee HW; Ji HY; Kim HH; Cho HY; Lee YB; Lee HS
    J Chromatogr B Analyt Technol Biomed Life Sci; 2003 Nov; 796(2):395-400. PubMed ID: 14581078
    [TBL] [Abstract][Full Text] [Related]  

  • 6. High-performance liquid chromatographic determination of propiverine and its N-oxide in human serum.
    Richter K; Scheithauer S; Thümmler D
    J Chromatogr B Biomed Sci Appl; 1998 Apr; 708(1-2):325-9. PubMed ID: 9653982
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rapid and sensitive liquid chromatography-electrospray ionization-mass spectrometry method for the determination of eperisone in human plasma: method and clinical applications.
    Ding L; Wei X; Zhang S; Sheng J; Zhang Y
    J Chromatogr Sci; 2004; 42(5):254-8. PubMed ID: 15189598
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A rapid determination of propiverine and its N-oxide metabolite in human plasma by high performance liquid chromatography-electrospray ionization tandem mass spectrometry.
    Yoon KH; Lee SY; Jang M; Ko SH; Kim W; Park JS; Park I; Kim HJ
    Talanta; 2005 May; 66(4):831-6. PubMed ID: 18970060
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A validated high-performance liquid chromatographic assay for the simultaneous determination of denaverine and its N-monodemethyl metabolite in human plasma.
    Staab A; Scheithauer S; Fieger-Büschges H; Mutschler E; Blume H
    J Chromatogr B Biomed Sci Appl; 2001 Feb; 751(2):221-8. PubMed ID: 11236077
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development and validation of a HPLC-ESI-MS/MS method for the determination of 5-aminosalicylic acid and its major metabolite N-acetyl-5-aminosalicylic acid in human plasma.
    Pastorini E; Locatelli M; Simoni P; Roda G; Roda E; Roda A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Sep; 872(1-2):99-106. PubMed ID: 18691952
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of tegaserod by LC-ESI-MS/MS and its application to a pharmacokinetic study in healthy Chinese volunteers.
    Zou JJ; Bian XJ; Ding L; Zhu YB; Fan HW; Xiao DW
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Jan; 861(1):151-7. PubMed ID: 18069077
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sensitive column-switching high-performance liquid chromatography method for determination of propiverine in human plasma.
    Ban E; Maeng JE; Woo JS; Kim CK
    J Chromatogr B Analyt Technol Biomed Life Sci; 2006 Feb; 831(1-2):230-5. PubMed ID: 16406746
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Determination of ritodrine in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.
    Liu A; Liu F; Xu Y; Xu F; Hu W; Guo Q
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(1):144-8. PubMed ID: 18378197
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Simultaneous determination of amoxicillin and clavulanic acid in human plasma by HPLC-ESI mass spectrometry.
    Yoon KH; Lee SY; Kim W; Park JS; Kim HJ
    J Chromatogr B Analyt Technol Biomed Life Sci; 2004 Dec; 813(1-2):121-7. PubMed ID: 15556524
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A rapid and sensitive liquid chromatography/positive ion tandem mass spectrometry method for the determination of cimetropium in human plasma by liquid-liquid extraction.
    Lee HW; Park WS; Kim YW; Cho SH; Kim SS; Seo JH; Lee KT
    J Mass Spectrom; 2006 Jul; 41(7):855-60. PubMed ID: 16810649
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Liquid chromatographic-tandem mass spectrometric method for the quantitation of sildenafil in human plasma.
    Wang Y; Wang J; Cui Y; Fawcett JP; Gu J
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Dec; 828(1-2):118-21. PubMed ID: 16203188
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Quantitation of tamsulosin in human plasma by liquid chromatography-electrospray ionization mass spectrometry.
    Din L; Li L; Tao P; Yang J; Zhang Z
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Feb; 767(1):75-81. PubMed ID: 11863298
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of tiapride in human plasma using hydrophilic interaction liquid chromatography-tandem mass spectrometry.
    Moon Y; Paek IB; Kim HH; Ji HY; Lee HW; Park HG; Lee HS
    Arch Pharm Res; 2004 Sep; 27(9):901-5. PubMed ID: 15473657
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Determination of faropenem in human plasma and urine by liquid chromatography-tandem mass spectrometry.
    Gao S; Chen W; Tao X; Miao H; Yang S; Wu R
    Biomed Chromatogr; 2008 Jan; 22(1):5-12. PubMed ID: 17604362
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Development and validation of a liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of D-amphetamine and diphenhydramine in beagle dog plasma and its application to a pharmacokinetic study.
    Wang C; Fan G; Lin M; Chen Y; Zhao W; Wu Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jul; 854(1-2):48-56. PubMed ID: 17452029
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.