145 related articles for article (PubMed ID: 14660051)
1. Inverted spin method for removing RBCs from BM buffy coat products.
Buckhalter R; Watkins K; Ericson SG
Cytotherapy; 2003; 5(6):553-7. PubMed ID: 14660051
[TBL] [Abstract][Full Text] [Related]
2. Predictive value of the original content of CD34(+) cells for enrichment of hematopoietic progenitor cells from bone marrow harvests by the apheresis procedure.
Itoh T; Minegishi M; Kudo Y; Saito N; Takahashi H; Suzuki A; Narita A; Sato Y; Miura J; Inoue Y; Kameoka J; Suwabe N; Imaizumi M; Okuda M; Tsuchiya S
J Clin Apher; 2006 Oct; 21(3):176-80. PubMed ID: 16619225
[TBL] [Abstract][Full Text] [Related]
3. CD34(+) hematopoietic progenitor cell selection of bone marrow grafts for autologous transplantation in pediatric patients.
Kasow KA; Sims-Poston L; Eldridge P; Hale GA
Biol Blood Marrow Transplant; 2007 May; 13(5):608-14. PubMed ID: 17448921
[TBL] [Abstract][Full Text] [Related]
4. A technique for isolation of bone marrow cells using hydroxyethyl starch (HES) sedimentation agent.
Montuoro A; De Rosa L; Del Monte C; Blandino F; Pandolfi A; Lanti T; De Laurenzi A
Haematologica; 1991 Mar; 76 Suppl 1():7-9. PubMed ID: 1713876
[TBL] [Abstract][Full Text] [Related]
5. Factors affecting volume reduction and red blood cell depletion of bone marrow on the COBE Spectra cell separator before haematopoietic stem cell transplantation.
Guttridge MG; Sidders C; Booth-Davey E; Pamphilon D; Watt SM
Bone Marrow Transplant; 2006 Aug; 38(3):175-81. PubMed ID: 16770313
[TBL] [Abstract][Full Text] [Related]
6. Multi-laboratory evaluation of procedures for reducing the volume of cord blood: influence on cell recoveries.
Takahashi TA; Rebulla P; Armitage S; van Beckhoven J; Eichler H; Kekomäki R; Letowska M; Wahab F; Moroff G
Cytotherapy; 2006; 8(3):254-64. PubMed ID: 16793734
[TBL] [Abstract][Full Text] [Related]
7. Red blood cell depletion from bone marrow and peripheral blood buffy coat: a comparison of two new and three established technologies.
Sorg N; Poppe C; Bunos M; Wingenfeld E; Hümmer C; Krämer A; Stock B; Seifried E; Bonig H
Transfusion; 2015 Jun; 55(6):1275-82. PubMed ID: 25647556
[TBL] [Abstract][Full Text] [Related]
8. The impact of CD34+ cell dose on platelet engraftment in pediatric patients following unmanipulated haploidentical blood and marrow transplantation.
Chang YJ; Xu LP; Liu DH; Liu KY; Han W; Chen YH; Wang Y; Chen H; Wang JZ; Zhang XH; Zhao XY; Huang XJ
Pediatr Blood Cancer; 2009 Dec; 53(6):1100-6. PubMed ID: 19743519
[TBL] [Abstract][Full Text] [Related]
9. Impact of harvest product volume in erythrocyte depletion of allogeneic or autologous bone marrow using COBE spectra.
Soydan E; Ayyildiz E; Dalva K; Topçuoğlu P; Tol M; Arslan O; Ilhan O; Arat M
Transfus Apher Sci; 2007 Jun; 36(3):269-73. PubMed ID: 17574924
[TBL] [Abstract][Full Text] [Related]
10. Storage duration and white blood cell content of red blood cell (RBC) products increases adhesion of stored RBCs to endothelium under flow conditions.
Anniss AM; Sparrow RL
Transfusion; 2006 Sep; 46(9):1561-7. PubMed ID: 16965584
[TBL] [Abstract][Full Text] [Related]
11. Combined bone marrow and peripheral blood progenitor cell autografts for patients with poor mobilization.
Sinitsyn Y; Malone A; Mandeli J; Grosskreutz C; Osman K; Scigliano E; Shi P; Isola L
Cytotherapy; 2009; 11(4):457-63. PubMed ID: 19499401
[TBL] [Abstract][Full Text] [Related]
12. Human bone marrow processing using Cobe 2991 and CS 3000 blood cell separators for further ex vivo manipulation.
Angelini A; Dragani A; Iacone A; D'Antonio D; Accorsi P; Quaglietta AM; Berardi A; Fioritoni G; Di Bartolomeo P; D'Emilio G
Haematologica; 1990; 75 Suppl 1():43-7. PubMed ID: 2351343
[TBL] [Abstract][Full Text] [Related]
13. ABO-mismatched marrow processing for transplantation: results of 114 procedures and analysis of immediate adverse events and hematopoietic recovery.
Larghero J; Rea D; Esperou H; Biscay N; Maurer MN; Lacassagne MN; Ternaux B; Traineau R; Yakouben K; Dosquet C; Socié G; Gluckman E; Benbunan M; Marolleau JP
Transfusion; 2006 Mar; 46(3):398-402. PubMed ID: 16533282
[TBL] [Abstract][Full Text] [Related]
14. Platelet engraftment in patients with hematologic malignancies following unmanipulated haploidentical blood and marrow transplantation: effects of CD34+ cell dose and disease status.
Chang YJ; Xu LP; Liu DH; Liu KY; Han W; Chen YH; Yu-Wang ; Chen H; Wang JZ; Zhang XH; Zhao XY; Huang XJ
Biol Blood Marrow Transplant; 2009 May; 15(5):632-8. PubMed ID: 19361756
[TBL] [Abstract][Full Text] [Related]
15. Quantification of nucleated red blood cells in allogeneic marrow graft and impact of processing on recovery.
Marolleau JP; Vanneaux V; Rea D; Ternaux B; Delasse V; Hubert V; Chantre E; Traineau R; Robin M; Benbunan M; Socié G; Larghero J
Transfusion; 2007 Feb; 47(2):266-71. PubMed ID: 17302773
[TBL] [Abstract][Full Text] [Related]
16. Pure red-cell aplasia following major and bi-directional ABO-incompatible allogeneic stem-cell transplantation: recovery of donor-derived erythropoiesis after long-term treatment using different therapeutic strategies.
Helbig G; Stella-Holowiecka B; Wojnar J; Krawczyk M; Krzemien S; Wojciechowska-Sadus M; Markiewicz M; Wylezol I; Kopera M; Holowiecki J
Ann Hematol; 2007 Sep; 86(9):677-83. PubMed ID: 17486341
[TBL] [Abstract][Full Text] [Related]
17. Isolation of purified autologous peripheral blood CD34+ cells with low T cell content using CliniMACS device--a local experience.
Leong CF; Habsah A; Teh HS; Goh KY; Fadilah SA; Cheong SK
Malays J Pathol; 2008 Jun; 30(1):31-6. PubMed ID: 19108409
[TBL] [Abstract][Full Text] [Related]
18. A randomized controlled clinical trial to determine the optimum duration of G-CSF priming prior to BM stem cell harvesting.
Lowenthal RM; Ragg SJ; Anderson J; Nicholson L; Harrup RA; Tuck D
Cytotherapy; 2007; 9(2):158-64. PubMed ID: 17453967
[TBL] [Abstract][Full Text] [Related]
19. Red blood cell depletion with a semiautomated system or hydroxyethyl starch sedimentation for routine cord blood banking: a comparative study.
Solves P; Mirabet V; Planelles D; Blasco I; Perales A; Carbonell-Uberos F; Soler MA; Roig R
Transfusion; 2005 Jun; 45(6):867-73. PubMed ID: 15934983
[TBL] [Abstract][Full Text] [Related]
20. A comparison of two protocols for optimal red blood cell depletion using Sepax-2 device for ABO-major incompatible transplantation in adults.
Fantin L; Olivieri CV; Spirito-Daffara F; Doglio A; Olivero S
Curr Res Transl Med; 2019 Aug; 67(3):107-111. PubMed ID: 30935875
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]