These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

106 related articles for article (PubMed ID: 1466408)

  • 1. Rebreathing and the Humphrey ADE breathing system.
    Ooi R; Soni N
    Anaesthesia; 1992 Nov; 47(11):1001-2. PubMed ID: 1466408
    [No Abstract]   [Full Text] [Related]  

  • 2. An evaluation of fresh gas flow rates for spontaneously breathing cats and small dogs on the Humphrey ADE semi-closed breathing system.
    Gale E; Ticehurst KE; Zaki S
    Vet Anaesth Analg; 2015 May; 42(3):292-8. PubMed ID: 25039422
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An assessment of the Humphrey ADE anaesthetic system in the Mapleson A mode during spontaneous ventilation.
    Dixon J; Chakrabarti MK; Morgan M
    Anaesthesia; 1984 Jun; 39(6):593-6. PubMed ID: 6742395
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Rebreathing characteristics of the Bain circuit. An experimental and theoretical study.
    Stenqvist O; Sonander H
    Br J Anaesth; 1984 Mar; 56(3):303-10. PubMed ID: 6422971
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Early detection of "rebreathing" in afferent and efferent reservoir breathing systems using capnography.
    Miller DM
    Br J Anaesth; 1990 Feb; 64(2):251-5. PubMed ID: 2107865
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Carbon dioxide homeostasis during anesthesia. IV. An evaluation of the partial rebreathing system.
    ELAM JO; BROWN ES
    Anesthesiology; 1956 Jan; 17(1):128-34. PubMed ID: 13283352
    [No Abstract]   [Full Text] [Related]  

  • 7. Humphrey ADE anaesthetic breathing system.
    Dorje P
    Anaesthesia; 1990 Apr; 45(4):341. PubMed ID: 2337222
    [No Abstract]   [Full Text] [Related]  

  • 8. The rebreathing characteristics of the Hudson oxygen mask.
    Campkin NT; Ooi RG; Soni NC
    Anaesthesia; 1993 Mar; 48(3):239-42. PubMed ID: 8460805
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison in spontaneous ventilation of the Maxima with the Humphrey ADE breathing system and between four methods for detecting rebreathing.
    Miller DM; Palm A
    Anaesth Intensive Care; 1995 Jun; 23(3):296-301. PubMed ID: 7573915
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Use of 15 mm tubing with the Humphrey ADE breathing system.
    Humphrey D
    Anaesthesia; 1992 Jul; 47(7):639-40. PubMed ID: 1626702
    [No Abstract]   [Full Text] [Related]  

  • 11. Modified parallel 'Lack' breathing system for use in dental anaesthesia.
    Blumgart CH; Hargrave SA
    Anaesthesia; 1992 Nov; 47(11):993-5. PubMed ID: 1466447
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The Humphrey ADE breathing system and ventilator alarms.
    Murphy PJ; Rabey PG
    Anaesthesia; 1991 Nov; 46(11):1000. PubMed ID: 1670498
    [No Abstract]   [Full Text] [Related]  

  • 13. Manual ventilation and the Humphrey ADE breathing systems.
    Humphrey D
    Anaesthesia; 1992 Jul; 47(7):625. PubMed ID: 1626684
    [No Abstract]   [Full Text] [Related]  

  • 14. Comparison of four methods of preoxygenation.
    McCrory JW; Matthews JN
    Br J Anaesth; 1990 May; 64(5):571-6. PubMed ID: 2112943
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ventilatory responses to rebreathing and carbon dioxide inhalation during anaesthesia in children.
    Lindahl SG; Charlton AJ; Hatch DJ
    Br J Anaesth; 1985 Dec; 57(12):1188-96. PubMed ID: 3936525
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of CO2 production and physiological deadspace on end-tidal CO2 during controlled ventilation: a study using a mechanical model.
    Stockwell MA; Bruce W; Soni N
    Anaesth Intensive Care; 1989 Nov; 17(4):482-6. PubMed ID: 2512821
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Carbon dioxide output in spontaneously breathing infants during anaesthesia and surgery.
    Lindahl S; Olsson AK; Thomson D
    Br J Anaesth; 1981 Jun; 53(6):647-51. PubMed ID: 6788055
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The additional work of breathing imposed by Mapleson A systems.
    Ooi R; Pattison J; Soni N
    Anaesthesia; 1993 Jul; 48(7):599-603. PubMed ID: 8346776
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Respiratory pattern and rebreathing in the Mapleson A, C and D breathing systems with spontaneous ventilation. A theory.
    Cook LB
    Anaesthesia; 1996 Apr; 51(4):371-85. PubMed ID: 8686829
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Spontaneous breathing with the Bain circuit at low flow rates: a case report.
    Mansell WH
    Can Anaesth Soc J; 1976 Jul; 23(4):432-4. PubMed ID: 947504
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.