These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
10. [A newly devised continuous catheter flush system for arterial pressure monitoring]. Hashimoto S; Sawa T; Chihara E; Kinoshita T; Hatanaka T; Hosokawa T; Natsuyama T; Tanaka Y Masui; 1989 Oct; 38(10):1378-82. PubMed ID: 2585707 [TBL] [Abstract][Full Text] [Related]
11. The fidelity and dynamic response of fluid-filled catheter systems for direct measurement of lumbar cerebrospinal fluid pressure. Kumar M; Werner E; Murray MJ J Clin Monit; 1993 Nov; 9(5):314-20. PubMed ID: 8106883 [TBL] [Abstract][Full Text] [Related]
12. Hazardous information from bedside fast-flush device test for fluid-filled pressure monitoring systems. Billiet E; Colardyn F Angiology; 1992 Dec; 43(12):988-95. PubMed ID: 1466487 [TBL] [Abstract][Full Text] [Related]
13. A new optical transducer for arterial pressure measurement. Hackman CH; Tan PS; Chakrabarti MK; Whitwam JG Br J Anaesth; 1991 Sep; 67(3):346-52. PubMed ID: 1911027 [TBL] [Abstract][Full Text] [Related]
14. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)]. Hellige G Basic Res Cardiol; 1976; 71(4):389-406. PubMed ID: 971217 [TBL] [Abstract][Full Text] [Related]
15. Invasive blood pressure monitoring systems in the ICU: influence of the blood-conserving device on the dynamic response characteristics and agreement with noninvasive measurements. Melamed R; Johnson K; Pothen B; Sprenkle MD; Johnson PJ Blood Press Monit; 2012 Oct; 17(5):179-83. PubMed ID: 22797516 [TBL] [Abstract][Full Text] [Related]
16. Dynamic response of a neonatal catheter-manometer system in situ. van Langen H; Brienesse P; Kopinga K; Wijn P J Clin Monit; 1993 Nov; 9(5):335-40. PubMed ID: 8106887 [TBL] [Abstract][Full Text] [Related]
17. The fast flush test--is the clinical comparison equivalent to its in vitro simulation? Kleinman B; Frey K; Stevens R J Clin Monit Comput; 1998 Dec; 14(7-8):485-9. PubMed ID: 10385857 [TBL] [Abstract][Full Text] [Related]
18. Recommendation of a clinical impulse response analysis for catheter calibration-dumping coefficient and natural frequency are incomplete parameters for clinical evaluation. Watanabe H; Yagi S; Namiki A J Clin Monit Comput; 2006 Feb; 20(1):37-42. PubMed ID: 16520875 [TBL] [Abstract][Full Text] [Related]
19. Contribution of measurement system artifacts to systolic spikes. Ladin Z; Trautman E; Teplick R Med Instrum; 1983; 17(2):110-2. PubMed ID: 6855647 [TBL] [Abstract][Full Text] [Related]
20. Construction and use of catheter-manometer systems. Heimann PA; Murray WB J Clin Monit; 1993 Jan; 9(1):45-53. PubMed ID: 8463804 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]