  • 1. The fast flush test measures the dynamic response of the entire blood pressure monitoring system.
    Kleinman B; Powell S; Kumar P; Gardner RM
    Anesthesiology; 1992 Dec; 77(6):1215-20. PubMed ID: 1466471
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Equivalence of fast flush and square wave testing of blood pressure monitoring systems.
    Kleinman B; Powell S; Gardner RM
    J Clin Monit; 1996 Mar; 12(2):149-54. PubMed ID: 8823635
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Experimental analysis of catheter-manometer systems in vitro and in vivo.
    Hipkins SF; Rutten AJ; Runciman WB
    Anesthesiology; 1989 Dec; 71(6):893-906. PubMed ID: 2589678
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Frequency response evaluation of radial artery catheter-manometer systems: sinusoidal frequency analysis versus flush method.
    Schwid HA
    J Clin Monit; 1988 Jul; 4(3):181-5. PubMed ID: 3210066
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Time-dependent pressure distortion in a catheter-transducer system: correction by fast flush.
    Promonet C; Anglade D; Menaouar A; Bayat S; Durand M; Eberhard A; Grimbert FA
    Anesthesiology; 2000 Jan; 92(1):208-18. PubMed ID: 10638918
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and dynamic response of disposable pressure transducer-tubing systems.
    Hunziker P
    Can J Anaesth; 1987 Jul; 34(4):409-14. PubMed ID: 3608063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Dynamic response of the ROSE damping device.
    Kleinman B; Powell S
    J Clin Monit; 1989 Apr; 5(2):111-5. PubMed ID: 2723705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of arterial pressure using catheter-transducer systems. Improvement using the Accudynamic.
    Allan MW; Gray WM; Asbury AJ
    Br J Anaesth; 1988 Mar; 60(4):413-8. PubMed ID: 3355737
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dynamics of invasive pressure monitoring systems: clinical and laboratory evaluation.
    Gibbs NC; Gardner RM
    Heart Lung; 1988 Jan; 17(1):43-51. PubMed ID: 3338943
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [A newly devised continuous catheter flush system for arterial pressure monitoring].
    Hashimoto S; Sawa T; Chihara E; Kinoshita T; Hatanaka T; Hosokawa T; Natsuyama T; Tanaka Y
    Masui; 1989 Oct; 38(10):1378-82. PubMed ID: 2585707
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The fidelity and dynamic response of fluid-filled catheter systems for direct measurement of lumbar cerebrospinal fluid pressure.
    Kumar M; Werner E; Murray MJ
    J Clin Monit; 1993 Nov; 9(5):314-20. PubMed ID: 8106883
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hazardous information from bedside fast-flush device test for fluid-filled pressure monitoring systems.
    Billiet E; Colardyn F
    Angiology; 1992 Dec; 43(12):988-95. PubMed ID: 1466487
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new optical transducer for arterial pressure measurement.
    Hackman CH; Tan PS; Chakrabarti MK; Whitwam JG
    Br J Anaesth; 1991 Sep; 67(3):346-52. PubMed ID: 1911027
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Recording of ventricular pressure by conventional catheter manometer systems. Efficiency of several combinations of conventional catheters, modern transducers and catheter-flush systems (author's transl)].
    Hellige G
    Basic Res Cardiol; 1976; 71(4):389-406. PubMed ID: 971217
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Invasive blood pressure monitoring systems in the ICU: influence of the blood-conserving device on the dynamic response characteristics and agreement with noninvasive measurements.
    Melamed R; Johnson K; Pothen B; Sprenkle MD; Johnson PJ
    Blood Press Monit; 2012 Oct; 17(5):179-83. PubMed ID: 22797516
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dynamic response of a neonatal catheter-manometer system in situ.
    van Langen H; Brienesse P; Kopinga K; Wijn P
    J Clin Monit; 1993 Nov; 9(5):335-40. PubMed ID: 8106887
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The fast flush test--is the clinical comparison equivalent to its in vitro simulation?
    Kleinman B; Frey K; Stevens R
    J Clin Monit Comput; 1998 Dec; 14(7-8):485-9. PubMed ID: 10385857
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Recommendation of a clinical impulse response analysis for catheter calibration-dumping coefficient and natural frequency are incomplete parameters for clinical evaluation.
    Watanabe H; Yagi S; Namiki A
    J Clin Monit Comput; 2006 Feb; 20(1):37-42. PubMed ID: 16520875
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contribution of measurement system artifacts to systolic spikes.
    Ladin Z; Trautman E; Teplick R
    Med Instrum; 1983; 17(2):110-2. PubMed ID: 6855647
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Construction and use of catheter-manometer systems.
    Heimann PA; Murray WB
    J Clin Monit; 1993 Jan; 9(1):45-53. PubMed ID: 8463804
    [TBL] [Abstract][Full Text] [Related]  