  • 41. [Comparison between continuous and intermittent thermodilution measurement of cardiac output during coronary artery bypass operation].
    Schulz K; Abel HH; Werning P
    Anasthesiol Intensivmed Notfallmed Schmerzther; 1997 Apr; 32(4):226-33. PubMed ID: 9289022
    [TBL] [Abstract][Full Text] [Related]  

  • 42. A comparison of the use of transoesophageal Doppler and thermodilution techniques for cardiac output determination.
    Keyl C; Rödig G; Lemberger P; Hobbhahn J
    Eur J Anaesthesiol; 1996 Mar; 13(2):136-42. PubMed ID: 8829946
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Three-dimensional transoesophageal echocardiography for cardiac output in critically ill patients: A pilot study of ultrasound versus the thermodilution method.
    Hammoudi N; Hékimian G; Laveau F; Achkar M; Isnard R; Combes A
    Arch Cardiovasc Dis; 2017 Jan; 110(1):7-13. PubMed ID: 28017278
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Measurement of cardiac output after cardiac surgery by a new transesophageal Doppler device.
    Jaeggi P; Hofer CK; Klaghofer R; Fodor P; Genoni M; Zollinger A
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):217-20. PubMed ID: 12698405
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Transgastric continuous-wave Doppler to determine cardiac output.
    Katz WE; Gasior TA; Quinlan JJ; Gorcsan J
    Am J Cardiol; 1993 Apr; 71(10):853-7. PubMed ID: 8456766
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Effect of the degree of tricuspid regurgitation on cardiac output measurements by thermodilution.
    Balik M; Pachl J; Hendl J
    Intensive Care Med; 2002 Aug; 28(8):1117-21. PubMed ID: 12185434
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    Boldt J; Menges T; Wollbrück M; Hammermann H; Hempelmann G
    Crit Care Med; 1994 Dec; 22(12):1913-8. PubMed ID: 7988126
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Effects of velocity distribution, diameter measurement and velocity tracing on the accuracy of cardiac output measurement by pulsed Doppler echocardiography in the aortic annulus of pigs.
    Zhou YQ; Faerestrand S; Birkeland S; Matre K; Husby P; Koller ME
    Ultrasound Med Biol; 1997; 23(2):177-85. PubMed ID: 9140176
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Noninvasive monitoring of cardiac output by Doppler echocardiography in patients treated with volume expansion after subarachnoid hemorrhage.
    Mayer SA; Sherman D; Fink ME; Homma S; Solomon RA; Lennihan L; Beckford A; Klebanoff LM
    Crit Care Med; 1995 Sep; 23(9):1470-4. PubMed ID: 7664547
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Estimation of cardiac output by noninvasive echocardiographic techniques in the critically ill subject.
    McLean AS; Needham A; Stewart D; Parkin R
    Anaesth Intensive Care; 1997 Jun; 25(3):250-4. PubMed ID: 9209605
    [TBL] [Abstract][Full Text] [Related]  

  • 51. Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance.
    Northridge DB; Findlay IN; Wilson J; Henderson E; Dargie HJ
    Br Heart J; 1990 Feb; 63(2):93-7. PubMed ID: 2317415
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Comparison of Doppler flow Tei-indexes with pulmonary artery thermodilution measurement of cardiac output in an experimental porcine model.
    Kobr J; Třeška V; Moláček J; Kuntscher V; Liška V; Slavík Z
    Physiol Res; 2011; 60(3):483-92. PubMed ID: 21401299
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.
    Valtier B; Cholley BP; Belot JP; de la Coussaye JE; Mateo J; Payen DM
    Am J Respir Crit Care Med; 1998 Jul; 158(1):77-83. PubMed ID: 9655710
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Simultaneous intraoperative measurement of cardiac output by thermodilution and transtracheal Doppler.
    Siegel LC; Fitzgerald DC; Engstrom RH
    Anesthesiology; 1991 Apr; 74(4):664-9. PubMed ID: 2008947
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Cardiac output measurement using the transesophageal Doppler method is less accurate than the thermodilution method when changing PaCO2.
    Sawai T; Nohmi T; Ohnishi Y; Takauchi Y; Kuro M
    Anesth Analg; 2005 Dec; 101(6):1597-1601. PubMed ID: 16301225
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Comparison of methods of cardiac output measurements determined by dye dilution, pulsed Doppler echocardiography and thermodilution in horses.
    Mizuno Y; Aida H; Hara H; Fujinaga T; Hagio M
    J Vet Med Sci; 1994 Feb; 56(1):1-5. PubMed ID: 8204732
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution.
    Bettex DA; Hinselmann V; Hellermann JP; Jenni R; Schmid ER
    Anaesthesia; 2004 Dec; 59(12):1184-92. PubMed ID: 15549977
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Assessment of the clinical utility of an ultrasonic monitor of cardiac output (the USCOM) and agreement with thermodilution measurement.
    Boyle M; Steel L; Flynn GM; Murgo M; Nicholson L; O'Brien M; Bihari D
    Crit Care Resusc; 2009 Sep; 11(3):198-203. PubMed ID: 19737122
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A comparison of thermodilution and pulsed Doppler cardiac output measurement in critically ill children.
    Notterman DA; Castello FV; Steinberg C; Greenwald BM; O'Loughlin JE; Gold JP
    J Pediatr; 1989 Oct; 115(4):554-60. PubMed ID: 2795345
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Comparison of thermodilution bolus cardiac output and Doppler cardiac output in the early post-cardiopulmonary bypass period.
    Zhao X; Mashikian JS; Panzica P; Lerner A; Park KW; Comunale ME
    J Cardiothorac Vasc Anesth; 2003 Apr; 17(2):193-8. PubMed ID: 12698401