These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

131 related articles for article (PubMed ID: 14670738)

  • 61. Development and validation of a liquid chromatography-isotope dilution tandem mass spectrometry for determination of olanzapine in human plasma and its application to bioavailability study.
    Zhang MQ; Jia JY; Lu C; Liu GY; Yu CY; Gui YZ; Liu Y; Liu YM; Wang W; Li SJ; Yu C
    Yao Xue Xue Bao; 2010 Jun; 45(6):767-71. PubMed ID: 20939188
    [TBL] [Abstract][Full Text] [Related]  

  • 62. Determination of reboxetine in rat brain microdialysates and plasma samples using liquid chromatography coupled to fluorescence detection.
    Shraim N; Clinckers R; Sarre S; Michotte Y; Van Eeckhaut A
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Jun; 898():53-61. PubMed ID: 22560340
    [TBL] [Abstract][Full Text] [Related]  

  • 63. Determination of meloxicam in human plasma by liquid chromatography-tandem mass spectrometry following transdermal administration.
    Yuan Y; Chen X; Zhong D
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jun; 852(1-2):650-4. PubMed ID: 17293175
    [TBL] [Abstract][Full Text] [Related]  

  • 64. Determination of tianeptine in tablets by high-performance liquid chromatography with fluorescence detection.
    Ulu ST
    J AOAC Int; 2007; 90(3):720-4. PubMed ID: 17580625
    [TBL] [Abstract][Full Text] [Related]  

  • 65. Determination of lefucoxib in rat plasma, urine, and feces by high-performance liquid chromatography with fluorescence detection: application in pharmacokinetic studies.
    Bi X; Meng Z; Dou G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 May; 850(1-2):199-205. PubMed ID: 17161982
    [TBL] [Abstract][Full Text] [Related]  

  • 66. Simultaneous assay of sildenafil and desmethylsildenafil in human plasma using liquid chromatography-tandem mass spectrometry on silica column with aqueous-organic mobile phase.
    Eerkes A; Addison T; Naidong W
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Mar; 768(2):277-84. PubMed ID: 11888056
    [TBL] [Abstract][Full Text] [Related]  

  • 67. Determination of ondansetron and its hydroxy metabolites in human serum using solid-phase extraction and liquid chromatography/positive ion electrospray tandem mass spectrometry.
    Xu X; Bartlett MG; Stewart JT
    J Mass Spectrom; 2000 Nov; 35(11):1329-34. PubMed ID: 11114092
    [TBL] [Abstract][Full Text] [Related]  

  • 68. Quantitation of zopiclone and desmethylzopiclone in human plasma by high-performance liquid chromatography using fluorescence detection.
    Nirogi RV; Kandikere VN; Mudigonda K
    Biomed Chromatogr; 2006 Aug; 20(8):794-9. PubMed ID: 16292747
    [TBL] [Abstract][Full Text] [Related]  

  • 69. Determination of ranolazine in human plasma by liquid chromatographic-tandem mass spectrometric assay.
    Zhao L; Li H; Jiang Y; Piao R; Li P; Gu J
    J Chromatogr Sci; 2008 Sep; 46(8):697-700. PubMed ID: 18796225
    [TBL] [Abstract][Full Text] [Related]  

  • 70. Determination of celiprolol in human plasma using high performance liquid chromatography with fluorescence detection for clinical application.
    Itohda A; Tsutsumi K; Imai H; Iwao M; Kotegawa T; Ohashi K
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Sep; 904():88-92. PubMed ID: 22889991
    [TBL] [Abstract][Full Text] [Related]  

  • 71. Simultaneous determination of four antipsychotic drugs in plasma by high-performance liquid chromatography. Application to management of acute intoxications.
    Garay Garcia L; Forfar-Bares I; Pehourcq F; Jarry C
    J Chromatogr B Analyt Technol Biomed Life Sci; 2003 Oct; 795(2):257-64. PubMed ID: 14522030
    [TBL] [Abstract][Full Text] [Related]  

  • 72. Development and validation of a high-performance liquid chromatography method using diode array detection for the simultaneous quantification of aripiprazole and dehydro-aripiprazole in human plasma.
    Lancelin F; Djebrani K; Tabaouti K; Kraoul L; Brovedani S; Paubel P; Piketty ML
    J Chromatogr B Analyt Technol Biomed Life Sci; 2008 May; 867(1):15-9. PubMed ID: 18356121
    [TBL] [Abstract][Full Text] [Related]  

  • 73. Determination of homocysteine in plasma by liquid chromatography with fluorescence detection.
    Gautier FC; Berneron C; Douce PJ
    Biomed Chromatogr; 1999 May; 13(3):239-43. PubMed ID: 10375126
    [TBL] [Abstract][Full Text] [Related]  

  • 74. Liquid chromatographic determination of sotalol in plasma and urine employing solid-phase extraction and fluorescence detection.
    Bartek MJ; Vekshteyn M; Boarman MP; Gallo DG
    J Chromatogr; 1987 Oct; 421(2):309-18. PubMed ID: 3429585
    [TBL] [Abstract][Full Text] [Related]  

  • 75. Simultaneous determination of hydrocodone and hydromorphone in human plasma by liquid chromatography with tandem mass spectrometric detection.
    Chen YL; Hanson GD; Jiang X; Naidong W
    J Chromatogr B Analyt Technol Biomed Life Sci; 2002 Mar; 769(1):55-64. PubMed ID: 11936695
    [TBL] [Abstract][Full Text] [Related]  

  • 76. Small blood volumes from children for quantitative sotalol determination using high-performance liquid chromatography.
    Läer S; Wauer I; Scholz H
    J Chromatogr B Biomed Sci Appl; 2001 Apr; 753(2):421-5. PubMed ID: 11334359
    [TBL] [Abstract][Full Text] [Related]  

  • 77. High-performance liquid chromatographic analysis of zolmitriptan in human plasma using fluorescence detection.
    Chen J; Jiang XG; Jiang WM; Mei N; Gao XL; Zhang QZ
    J Pharm Biomed Anal; 2004 May; 35(3):639-45. PubMed ID: 15137991
    [TBL] [Abstract][Full Text] [Related]  

  • 78. Validation of a sensitive LC/MS/MS method for simultaneous quantitation of flupentixol and melitracene in human plasma.
    Che J; Meng Q; Chen Z; San C; Hou Y; Cheng Y
    J Pharm Biomed Anal; 2007 Dec; 45(5):785-92. PubMed ID: 17881181
    [TBL] [Abstract][Full Text] [Related]  

  • 79. High-throughput, semi-automated determination of a cyclooxygenase II inhibitor in human plasma and urine using solid-phase extraction in the 96-well format and high-performance liquid chromatography with post-column photochemical derivatization-fluorescence detection.
    Matthews CZ; Woolf EJ; Lin L; Fang W; Hsieh J; Ha S; Simpson R; Matuszewski BK
    J Chromatogr B Biomed Sci Appl; 2001 Feb; 751(2):237-46. PubMed ID: 11236079
    [TBL] [Abstract][Full Text] [Related]  

  • 80. Determination of losartan, telmisartan, and valsartan by direct injection of human urine into a column-switching liquid chromatographic system with fluorescence detection.
    del Rosario Brunetto M; Contreras Y; Clavijo S; Torres D; Delgado Y; Ovalles F; Ayala C; Gallignani M; Estela JM; Martin VC
    J Pharm Biomed Anal; 2009 Sep; 50(2):194-9. PubMed ID: 19446420
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.