These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
5. Accuracy of drawing coagulation samples from heparinized arterial lines. Templin K; Shively M; Riley J Am J Crit Care; 1993 Jan; 2(1):88-95. PubMed ID: 8353585 [TBL] [Abstract][Full Text] [Related]
6. Significant increase of activated partial thromboplastin time by heparinization of the radial artery catheter flush solution with a closed arterial catheter system. Hoste EA; Roels NR; Decruyenaere JM; Colardyn FA Crit Care Med; 2002 May; 30(5):1030-4. PubMed ID: 12006799 [TBL] [Abstract][Full Text] [Related]
7. Comparison of bedside coagulation monitoring tests with standard laboratory tests in patients after cardiac surgery. Reich DL; Yanakakis MJ; Vela-Cantos FP; DePerio M; Jacobs E Anesth Analg; 1993 Oct; 77(4):673-9. PubMed ID: 8214648 [TBL] [Abstract][Full Text] [Related]
8. Intra-arterial blood sampling for clotting studies. Effects of heparin contamination. Lew JK; Hutchinson R; Lin ES Anaesthesia; 1991 Sep; 46(9):719-21. PubMed ID: 1928668 [TBL] [Abstract][Full Text] [Related]
10. Underestimation of plasma level of factor V coagulant activity and fibrinogen concentration together with prolonged prothrombin time, activated partial thromboplastin time and thrombin time can result from pre-analytical very low calcium level in citrated sample tube. d'Audigier C; Delassasseigne C; Robert A; Eschwège V Int J Lab Hematol; 2016 Feb; 38(1):50-3. PubMed ID: 26406495 [TBL] [Abstract][Full Text] [Related]
12. Intraoperative measurement of activated partial thromboplastin time and prothrombin time by a portable laser photometer in patients following cardiopulmonary bypass. Nuttall GA; Oliver WC; Beynen FM; Dull JJ; Murray MJ; Nichols WL J Cardiothorac Vasc Anesth; 1993 Aug; 7(4):402-9. PubMed ID: 8400094 [TBL] [Abstract][Full Text] [Related]
13. Prospective randomized evaluation of two methods of drawing coagulation studies from heparinized arterial lines. Cannon K; Mitchell KA; Fabian TC Heart Lung; 1985 Jul; 14(4):392-5. PubMed ID: 3847416 [TBL] [Abstract][Full Text] [Related]
14. The order of draw: much ado about nothing? Indevuyst C; Schuermans W; Bailleul E; Meeus P Int J Lab Hematol; 2015 Feb; 37(1):50-5. PubMed ID: 24712307 [TBL] [Abstract][Full Text] [Related]
15. Comparison of PT and aPTT values drawn by venipuncture and arterial line using three discard volumes. Konopad E; Grace M; Johnston R; Noseworthy T; Shustack A Am J Crit Care; 1992 Nov; 1(3):94-101. PubMed ID: 1307912 [TBL] [Abstract][Full Text] [Related]
16. A comparison of heparinised and non-heparinised normal saline solutions for maintaining the patency of arterial pressure measurement cannulae after heart surgery. Xiong J; Pan T; Jin H; Xie X; Wang Y; Wang D J Cardiothorac Surg; 2019 Feb; 14(1):39. PubMed ID: 30808385 [TBL] [Abstract][Full Text] [Related]
17. Can we rely on arterial line sampling in performing activated plasma thromboplastin time after cardiac surgery? Alzetani A; Vohra HA; Patel RL Eur J Anaesthesiol; 2004 May; 21(5):384-8. PubMed ID: 15141797 [TBL] [Abstract][Full Text] [Related]
18. [Monitoring heparin therapy by thrombin time and activated partial thromboplastin time--a comparison]. Lang M; Fey MF; Furlan M; Beck EA Schweiz Med Wochenschr; 1986 Nov; 116(48):1681-4. PubMed ID: 3798064 [TBL] [Abstract][Full Text] [Related]
19. Standardization of coagulation tests. Opartkiattikul N Southeast Asian J Trop Med Public Health; 1999; 30 Suppl 3():79-85. PubMed ID: 10926265 [TBL] [Abstract][Full Text] [Related]
20. Accuracy of coagulation values obtained from a heparinized central venous catheter. Pinto KM Oncol Nurs Forum; 1994 Apr; 21(3):573-5. PubMed ID: 8052553 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]