These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

142 related articles for article (PubMed ID: 14672563)

  • 1. Flow-tissue interaction with compliance mismatch in a model stented artery.
    Tortoriello A; Pedrizzetti G
    J Biomech; 2004 Jan; 37(1):1-11. PubMed ID: 14672563
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Hydrodynamic effects of compliance mismatch in stented arteries.
    Selvarasu NK; Tafti DK; Vlachos PP
    J Biomech Eng; 2011 Feb; 133(2):021008. PubMed ID: 21280880
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Alterations in regional vascular geometry produced by theoretical stent implantation influence distributions of wall shear stress: analysis of a curved coronary artery using 3D computational fluid dynamics modeling.
    LaDisa JF; Olson LE; Douglas HA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2006 Jun; 5():40. PubMed ID: 16780592
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulsatile flow inside moderately elastic arteries, its modelling and effects of elasticity.
    Pedrizzetti G; Domenichini F; Tortoriello A; Zovatto L
    Comput Methods Biomech Biomed Engin; 2002 Jun; 5(3):219-31. PubMed ID: 12186714
    [TBL] [Abstract][Full Text] [Related]  

  • 5. DPIV measurements of flow disturbances in stented artery models: adverse affects of compliance mismatch.
    Yazdani SK; Moore JE; Berry JL; Vlachos PP
    J Biomech Eng; 2004 Oct; 126(5):559-66. PubMed ID: 15648808
    [TBL] [Abstract][Full Text] [Related]  

  • 6. On using experimentally estimated wall shear stresses to validate numerically predicted results.
    Walsh M; McGloughlin T; Liepsch DW; O'Brien T; Morris L; Ansari AR
    Proc Inst Mech Eng H; 2003; 217(2):77-90. PubMed ID: 12666774
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Axial stent strut angle influences wall shear stress after stent implantation: analysis using 3D computational fluid dynamics models of stent foreshortening.
    LaDisa JF; Olson LE; Hettrick DA; Warltier DC; Kersten JR; Pagel PS
    Biomed Eng Online; 2005 Oct; 4():59. PubMed ID: 16250918
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Computational fluid dynamics analysis of balloon-expandable coronary stents: influence of stent and vessel deformation.
    Martin DM; Murphy EA; Boyle FJ
    Med Eng Phys; 2014 Aug; 36(8):1047-56. PubMed ID: 24953569
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Three-dimensional computational fluid dynamics modeling of alterations in coronary wall shear stress produced by stent implantation.
    LaDisa JF; Guler I; Olson LE; Hettrick DA; Kersten JR; Warltier DC; Pagel PS
    Ann Biomed Eng; 2003 Sep; 31(8):972-80. PubMed ID: 12918912
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Circumferential vascular deformation after stent implantation alters wall shear stress evaluated with time-dependent 3D computational fluid dynamics models.
    LaDisa JF; Olson LE; Guler I; Hettrick DA; Kersten JR; Warltier DC; Pagel PS
    J Appl Physiol (1985); 2005 Mar; 98(3):947-57. PubMed ID: 15531564
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood flow in stented arteries: a parametric comparison of strut design patterns in three dimensions.
    He Y; Duraiswamy N; Frank AO; Moore JE
    J Biomech Eng; 2005 Aug; 127(4):637-47. PubMed ID: 16121534
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Compliance and diameter mismatch affect the wall shear rate distribution near an end-to-end anastomosis.
    Weston MW; Rhee K; Tarbell JM
    J Biomech; 1996 Feb; 29(2):187-98. PubMed ID: 8849812
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Modelling of flow and wall behaviour in a mildly stenosed tube.
    Lee KW; Xu XY
    Med Eng Phys; 2002 Nov; 24(9):575-86. PubMed ID: 12376044
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate.
    Swillens A; Degroote J; Vierendeels J; Lovstakken L; Segers P
    Med Phys; 2010 Aug; 37(8):4318-30. PubMed ID: 20879592
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of compliance mismatch on blood flow in an artery with endovascular prosthesis.
    Surovtsova I
    J Biomech; 2005 Oct; 38(10):2078-86. PubMed ID: 16084208
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Developing pulsatile flow in a deployed coronary stent.
    Rajamohan D; Banerjee RK; Back LH; Ibrahim AA; Jog MA
    J Biomech Eng; 2006 Jun; 128(3):347-59. PubMed ID: 16706584
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia.
    Hofer M; Rappitsch G; Perktold K; Trubel W; Schima H
    J Biomech; 1996 Oct; 29(10):1297-308. PubMed ID: 8884475
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Compound ex vivo and in silico method for hemodynamic analysis of stented arteries.
    Rikhtegar F; Pacheco F; Wyss C; Stok KS; Ge H; Choo RJ; Ferrari A; Poulikakos D; Müller R; Kurtcuoglu V
    PLoS One; 2013; 8(3):e58147. PubMed ID: 23516442
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A multiscale approach for modelling wave propagation in an arterial segment.
    Pontrelli G
    Comput Methods Biomech Biomed Engin; 2004 Apr; 7(2):79-89. PubMed ID: 15203956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Changes in blood flow due to stented parent artery expansion in an intracranial aneurysm.
    Mori F; Ohta M; Matsuzawa T
    Technol Health Care; 2015; 23(1):9-21. PubMed ID: 25391531
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.