These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
814 related articles for article (PubMed ID: 14673832)
1. Ionization enhancement in atmospheric pressure chemical ionization and suppression in electrospray ionization between target drugs and stable-isotope-labeled internal standards in quantitative liquid chromatography/tandem mass spectrometry. Liang HR; Foltz RL; Meng M; Bennett P Rapid Commun Mass Spectrom; 2003; 17(24):2815-21. PubMed ID: 14673832 [TBL] [Abstract][Full Text] [Related]
2. Systematic investigation of ion suppression and enhancement effects of fourteen stable-isotope-labeled internal standards by their native analogues using atmospheric-pressure chemical ionization and electrospray ionization and the relevance for multi-analyte liquid chromatographic/mass spectrometric procedures. Remane D; Wissenbach DK; Meyer MR; Maurer HH Rapid Commun Mass Spectrom; 2010 Apr; 24(7):859-67. PubMed ID: 20196193 [TBL] [Abstract][Full Text] [Related]
3. Quantitative determination of endogenous sorbitol and fructose in human nerve tissues by atmospheric-pressure chemical ionization liquid chromatography/tandem mass spectrometry. Liang HR; Takagaki T; Foltz RL; Bennett P Rapid Commun Mass Spectrom; 2005; 19(16):2284-94. PubMed ID: 16034846 [TBL] [Abstract][Full Text] [Related]
4. Quantitative determination of endogenous sorbitol and fructose in human erythrocytes by atmospheric-pressure chemical ionization LC tandem mass spectrometry. Liang HR; Takagaki T; Foltz RL; Bennett P J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Sep; 824(1-2):36-44. PubMed ID: 16061433 [TBL] [Abstract][Full Text] [Related]
5. Ion suppression and enhancement effects of co-eluting analytes in multi-analyte approaches: systematic investigation using ultra-high-performance liquid chromatography/mass spectrometry with atmospheric-pressure chemical ionization or electrospray ionization. Remane D; Meyer MR; Wissenbach DK; Maurer HH Rapid Commun Mass Spectrom; 2010 Nov; 24(21):3103-8. PubMed ID: 20941756 [TBL] [Abstract][Full Text] [Related]
6. Application of co-eluting structural analog internal standards for expanded linear dynamic range in liquid chromatography/electrospray mass spectrometry. Shi G Rapid Commun Mass Spectrom; 2003; 17(3):202-6. PubMed ID: 12539184 [TBL] [Abstract][Full Text] [Related]
7. Monitoring phospholipids for assessment of ion enhancement and ion suppression in ESI and APCI LC/MS/MS for chlorpheniramine in human plasma and the importance of multiple source matrix effect evaluations. Ismaiel OA; Halquist MS; Elmamly MY; Shalaby A; Thomas Karnes H J Chromatogr B Analyt Technol Biomed Life Sci; 2008 Nov; 875(2):333-43. PubMed ID: 18926779 [TBL] [Abstract][Full Text] [Related]
8. Quantitation of lysergic acid diethylamide in urine using atmospheric pressure matrix-assisted laser desorption/ionization ion trap mass spectrometry. Cui M; McCooeye MA; Fraser C; Mester Z Anal Chem; 2004 Dec; 76(23):7143-8. PubMed ID: 15571372 [TBL] [Abstract][Full Text] [Related]
9. Development and evaluation of a candidate reference method for the determination of total cortisol in human serum using isotope dilution liquid chromatography/mass spectrometry and liquid chromatography/tandem mass spectrometry. Tai SS; Welch MJ Anal Chem; 2004 Feb; 76(4):1008-14. PubMed ID: 14961732 [TBL] [Abstract][Full Text] [Related]
10. Laser diode thermal desorption-positive mode atmospheric pressure chemical ionization tandem mass spectrometry for the ultra-fast quantification of a pharmaceutical compound in human plasma. Heudi O; Barteau S; Picard P; Tremblay P; Picard F; Kretz O J Pharm Biomed Anal; 2011 Apr; 54(5):1088-95. PubMed ID: 21156343 [TBL] [Abstract][Full Text] [Related]
11. Matrix matching in liquid chromatography-mass spectrometry with stable isotope labelled internal standards--is it necessary? Hewavitharana AK J Chromatogr A; 2011 Jan; 1218(2):359-61. PubMed ID: 21159347 [TBL] [Abstract][Full Text] [Related]
12. Quantitative determination of acetylcholine in microdialysis samples using liquid chromatography/atmospheric pressure spray ionization mass spectrometry. Keski-Rahkonen P; Lehtonen M; Ihalainen J; Sarajärvi T; Auriola S Rapid Commun Mass Spectrom; 2007; 21(18):2933-43. PubMed ID: 17680629 [TBL] [Abstract][Full Text] [Related]
13. Characterizing and compensating for matrix effects using atmospheric pressure chemical ionization liquid chromatography-tandem mass spectrometry: analysis of neutral pharmaceuticals in municipal wastewater. Zhao X; Metcalfe CD Anal Chem; 2008 Mar; 80(6):2010-7. PubMed ID: 18290635 [TBL] [Abstract][Full Text] [Related]
14. Method development aspects for the quantitation of pharmaceutical compounds in human plasma with a matrix-assisted laser desorption/ionization source in the multiple reaction monitoring mode. Kovarik P; Grivet C; Bourgogne E; Hopfgartner G Rapid Commun Mass Spectrom; 2007; 21(6):911-9. PubMed ID: 17295425 [TBL] [Abstract][Full Text] [Related]
15. Employing atmospheric pressure photoionization in liquid chromatography/tandem mass spectrometry to minimize ion suppression and matrix effects for the quantification of venlafaxine and O-desmethylvenlafaxine. Theron HB; van der Merwe MJ; Swart KJ; van der Westhuizen JH Rapid Commun Mass Spectrom; 2007; 21(10):1680-6. PubMed ID: 17465011 [TBL] [Abstract][Full Text] [Related]
16. Ultra-performance liquid chromatography/tandem mass spectrometric quantification of structurally diverse drug mixtures using an ESI-APCI multimode ionization source. Yu K; Di L; Kerns E; Li SQ; Alden P; Plumb RS Rapid Commun Mass Spectrom; 2007; 21(6):893-902. PubMed ID: 17295426 [TBL] [Abstract][Full Text] [Related]
17. Comparison of electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization for determining estrogenic chemicals in water by liquid chromatography tandem mass spectrometry with chemical derivatizations. Lien GW; Chen CY; Wang GS J Chromatogr A; 2009 Feb; 1216(6):956-66. PubMed ID: 19118834 [TBL] [Abstract][Full Text] [Related]
18. Simultaneous determination of tetrahydrocortisol, allotetrahydrocortisol and tetrahydrocortisone in human urine by liquid chromatography-electrospray ionization tandem mass spectrometry. Yamashita K; Nakagawa R; Okuyama M; Honma S; Takahashi M; Numazawa M Steroids; 2008 Aug; 73(7):727-37. PubMed ID: 18394666 [TBL] [Abstract][Full Text] [Related]
19. Quantitative determination of zidovudine diaryl phosphate triester pro-drugs in rat plasma by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry. Zhu M; Xie B; Tang G; Hu A; Fang M; Wu Z; Zhao Y J Pharm Biomed Anal; 2008 Dec; 48(5):1417-24. PubMed ID: 19118970 [TBL] [Abstract][Full Text] [Related]
20. Quantitative analysis of amyloid beta peptides in cerebrospinal fluid of Alzheimer's disease patients by immunoaffinity purification and stable isotope dilution liquid chromatography/negative electrospray ionization tandem mass spectrometry. Oe T; Ackermann BL; Inoue K; Berna MJ; Garner CO; Gelfanova V; Dean RA; Siemers ER; Holtzman DM; Farlow MR; Blair IA Rapid Commun Mass Spectrom; 2006; 20(24):3723-35. PubMed ID: 17117458 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]