BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 14675002)

  • 21. Effect of changing capacitors between phases of a biphasic defibrillation shock.
    Walcott GP; Rollins DL; Smith WM; Ideker RE
    Pacing Clin Electrophysiol; 1996 Jun; 19(6):945-54. PubMed ID: 8774825
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Optimizing defibrillation through improved waveforms.
    Block M; Breithardt G
    Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):526-38. PubMed ID: 7777417
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Truncated biphasic pulses for transthoracic defibrillation.
    Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G
    Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation.
    Walcott GP; Walker RG; Cates AW; Krassowska W; Smith WM; Ideker RE
    J Cardiovasc Electrophysiol; 1995 Sep; 6(9):737-50. PubMed ID: 8556194
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Optimizing defibrillation waveforms for ICDs.
    Kroll MW; Swerdlow CD
    J Interv Card Electrophysiol; 2007 Apr; 18(3):247-63. PubMed ID: 17541815
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Influence of phase duration of biphasic waveforms on defibrillation energy requirements with a 70-microF capacitance.
    Schauerte P; Schöndube FA; Grossmann M; Dörge H; Stein F; Dohmen B; Moumen A; Erena K; Messmer BJ; Hanrath P; Stellbrink C
    Circulation; 1998 May; 97(20):2073-8. PubMed ID: 9610539
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators.
    Swerdlow CD; Kass RM; Chen PS; Hwang C; Raissi S
    Circulation; 1994 Oct; 90(4):1840-6. PubMed ID: 7923670
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system.
    Poole JE; Bardy GH; Kudenchuk PJ; Dolack GL; Raitt MH; Mehra R; Johnson G
    Pacing Clin Electrophysiol; 1995 Jul; 18(7):1369-73. PubMed ID: 7567589
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator.
    Brugada J; Herse B; Sandsted B; Michel U; Schubert BD; Hahn SJ
    Europace; 2001 Oct; 3(4):278-84. PubMed ID: 11678385
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Strength-duration and probability of success curves for defibrillation with biphasic waveforms.
    Feeser SA; Tang AS; Kavanagh KM; Rollins DL; Smith WM; Wolf PD; Ideker RE
    Circulation; 1990 Dec; 82(6):2128-41. PubMed ID: 2242537
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Comparison of biphasic and monophasic defibrillation waveforms in an isolated rabbit heart preparation.
    Holley LK; McCulloch RM
    Cardiovasc Res; 1991 Dec; 25(12):979-83. PubMed ID: 1806236
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices.
    Yamanouchi Y; Brewer JE; Mowrey KA; Kroll MW; Donohoo AM; Wilkoff BL; Tchou PJ
    J Cardiovasc Electrophysiol; 1997 May; 8(5):517-28. PubMed ID: 9160228
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Internal defibrillation with smaller capacitors: a prospective randomized cross-over comparison of defibrillation efficacy obtained with 90-microF and 125-microF capacitors in humans.
    Block M; Hammel D; Böcker D; Borggrefe M; Seifert T; Fastenrath C; Scheld HH; Breithardt G
    J Cardiovasc Electrophysiol; 1995 May; 6(5):333-42. PubMed ID: 7551301
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Strength-duration relationship for human transvenous defibrillation.
    Gold MR; Shorofsky SR
    Circulation; 1997 Nov; 96(10):3517-20. PubMed ID: 9396449
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of the efficacy of defibrillation with the damped sine and constant-tilt current waveforms in the intact animal.
    Hinds M; Ayers GM; Bourland JD; Geddes LA; Tacker WA; Fearnot N
    Med Instrum; 1987 Apr; 21(2):92-6. PubMed ID: 3614037
    [TBL] [Abstract][Full Text] [Related]  

  • 36. "Tuned" defibrillation waveforms outperform 50/50% tilt defibrillation waveforms: a randomized multi-center study.
    Natarajan S; Henthorn R; Burroughs J; Esberg D; Zweibel S; Ross T; Kroll M; Gianola D; Oza A
    Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S139-42. PubMed ID: 17302691
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of defibrillation efficacy using biphasic waveforms delivered from various capacitances/pulse widths.
    Lin JH; Stotts LJ; Rosborough JP; Frederick H
    Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 2):158-62. PubMed ID: 9121981
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Comparison of biphasic and monophasic pulses: does the advantage of biphasic shocks depend on the waveshape?
    Natale A; Sra J; Krum D; Dhala A; Deshpande S; Jazayeri M; Axtell K; Degroot P; VanHout WL; Akhtar M
    Pacing Clin Electrophysiol; 1995 Jul; 18(7):1354-61. PubMed ID: 7567587
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of second-phase duration on the strength-duration relation for human transvenous defibrillation.
    Shorofsky SR; Gold MR
    Circulation; 2000 Oct; 102(18):2239-42. PubMed ID: 11056099
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy.
    Jones JL; Swartz JF; Jones RE; Fletcher R
    Circ Res; 1990 Aug; 67(2):376-84. PubMed ID: 2376078
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.