21. Effect of changing capacitors between phases of a biphasic defibrillation shock.
Walcott GP; Rollins DL; Smith WM; Ideker RE
Pacing Clin Electrophysiol; 1996 Jun; 19(6):945-54. PubMed ID: 8774825
[TBL] [Abstract][Full Text] [Related]
22. Optimizing defibrillation through improved waveforms.
Block M; Breithardt G
Pacing Clin Electrophysiol; 1995 Mar; 18(3 Pt 2):526-38. PubMed ID: 7777417
[TBL] [Abstract][Full Text] [Related]
23. Truncated biphasic pulses for transthoracic defibrillation.
Bardy GH; Gliner BE; Kudenchuk PJ; Poole JE; Dolack GL; Jones GK; Anderson J; Troutman C; Johnson G
Circulation; 1995 Mar; 91(6):1768-74. PubMed ID: 7882486
[TBL] [Abstract][Full Text] [Related]
24. Choosing the optimal monophasic and biphasic waveforms for ventricular defibrillation.
Walcott GP; Walker RG; Cates AW; Krassowska W; Smith WM; Ideker RE
J Cardiovasc Electrophysiol; 1995 Sep; 6(9):737-50. PubMed ID: 8556194
[TBL] [Abstract][Full Text] [Related]
25. Optimizing defibrillation waveforms for ICDs.
Kroll MW; Swerdlow CD
J Interv Card Electrophysiol; 2007 Apr; 18(3):247-63. PubMed ID: 17541815
[TBL] [Abstract][Full Text] [Related]
26. Influence of phase duration of biphasic waveforms on defibrillation energy requirements with a 70-microF capacitance.
Schauerte P; Schöndube FA; Grossmann M; Dörge H; Stein F; Dohmen B; Moumen A; Erena K; Messmer BJ; Hanrath P; Stellbrink C
Circulation; 1998 May; 97(20):2073-8. PubMed ID: 9610539
[TBL] [Abstract][Full Text] [Related]
27. Effect of capacitor size and pathway resistance on defibrillation threshold for implantable defibrillators.
Swerdlow CD; Kass RM; Chen PS; Hwang C; Raissi S
Circulation; 1994 Oct; 90(4):1840-6. PubMed ID: 7923670
[TBL] [Abstract][Full Text] [Related]
28. Prospective randomized comparison of biphasic waveform tilt using a unipolar defibrillation system.
Poole JE; Bardy GH; Kudenchuk PJ; Dolack GL; Raitt MH; Mehra R; Johnson G
Pacing Clin Electrophysiol; 1995 Jul; 18(7):1369-73. PubMed ID: 7567589
[TBL] [Abstract][Full Text] [Related]
29. Clinical evaluation of defibrillation efficacy with a new single-capacitor biphasic waveform in patients undergoing implantation of an implantable cardioverter defibrillator.
Brugada J; Herse B; Sandsted B; Michel U; Schubert BD; Hahn SJ
Europace; 2001 Oct; 3(4):278-84. PubMed ID: 11678385
[TBL] [Abstract][Full Text] [Related]
30. Strength-duration and probability of success curves for defibrillation with biphasic waveforms.
Feeser SA; Tang AS; Kavanagh KM; Rollins DL; Smith WM; Wolf PD; Ideker RE
Circulation; 1990 Dec; 82(6):2128-41. PubMed ID: 2242537
[TBL] [Abstract][Full Text] [Related]
31. Comparison of biphasic and monophasic defibrillation waveforms in an isolated rabbit heart preparation.
Holley LK; McCulloch RM
Cardiovasc Res; 1991 Dec; 25(12):979-83. PubMed ID: 1806236
[TBL] [Abstract][Full Text] [Related]
32. Sawtooth first phase biphasic defibrillation waveform: a comparison with standard waveform in clinical devices.
Yamanouchi Y; Brewer JE; Mowrey KA; Kroll MW; Donohoo AM; Wilkoff BL; Tchou PJ
J Cardiovasc Electrophysiol; 1997 May; 8(5):517-28. PubMed ID: 9160228
[TBL] [Abstract][Full Text] [Related]
33. Internal defibrillation with smaller capacitors: a prospective randomized cross-over comparison of defibrillation efficacy obtained with 90-microF and 125-microF capacitors in humans.
Block M; Hammel D; Böcker D; Borggrefe M; Seifert T; Fastenrath C; Scheld HH; Breithardt G
J Cardiovasc Electrophysiol; 1995 May; 6(5):333-42. PubMed ID: 7551301
[TBL] [Abstract][Full Text] [Related]
34. Strength-duration relationship for human transvenous defibrillation.
Gold MR; Shorofsky SR
Circulation; 1997 Nov; 96(10):3517-20. PubMed ID: 9396449
[TBL] [Abstract][Full Text] [Related]
35. Comparison of the efficacy of defibrillation with the damped sine and constant-tilt current waveforms in the intact animal.
Hinds M; Ayers GM; Bourland JD; Geddes LA; Tacker WA; Fearnot N
Med Instrum; 1987 Apr; 21(2):92-6. PubMed ID: 3614037
[TBL] [Abstract][Full Text] [Related]
36. "Tuned" defibrillation waveforms outperform 50/50% tilt defibrillation waveforms: a randomized multi-center study.
Natarajan S; Henthorn R; Burroughs J; Esberg D; Zweibel S; Ross T; Kroll M; Gianola D; Oza A
Pacing Clin Electrophysiol; 2007 Jan; 30 Suppl 1():S139-42. PubMed ID: 17302691
[TBL] [Abstract][Full Text] [Related]
37. Comparison of defibrillation efficacy using biphasic waveforms delivered from various capacitances/pulse widths.
Lin JH; Stotts LJ; Rosborough JP; Frederick H
Pacing Clin Electrophysiol; 1997 Jan; 20(1 Pt 2):158-62. PubMed ID: 9121981
[TBL] [Abstract][Full Text] [Related]
38. Comparison of biphasic and monophasic pulses: does the advantage of biphasic shocks depend on the waveshape?
Natale A; Sra J; Krum D; Dhala A; Deshpande S; Jazayeri M; Axtell K; Degroot P; VanHout WL; Akhtar M
Pacing Clin Electrophysiol; 1995 Jul; 18(7):1354-61. PubMed ID: 7567587
[TBL] [Abstract][Full Text] [Related]
39. Effect of second-phase duration on the strength-duration relation for human transvenous defibrillation.
Shorofsky SR; Gold MR
Circulation; 2000 Oct; 102(18):2239-42. PubMed ID: 11056099
[TBL] [Abstract][Full Text] [Related]
40. Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy.
Jones JL; Swartz JF; Jones RE; Fletcher R
Circ Res; 1990 Aug; 67(2):376-84. PubMed ID: 2376078
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]