These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device. Schönberger M; Deutsch S; Manning KB ASAIO J; 2012; 58(5):481-93. PubMed ID: 22929894 [TBL] [Abstract][Full Text] [Related]
9. Evaluating the flow characteristics of artificial pumping devices using nuclear scintigraphy. Christensen CW; Gao H; Smith LM; Krymkowski MG; Schmidt DH Artif Organs; 1993 Oct; 17(10):843-9. PubMed ID: 8274102 [TBL] [Abstract][Full Text] [Related]
10. Numerical analysis of the three-dimensional blood flow in the korean artificial heart. Shim EB; Yeo JY; Ko HJ; Youn CH; Lee YR; Park CY; Min BG; Sun K Artif Organs; 2003 Jan; 27(1):49-60. PubMed ID: 12534713 [TBL] [Abstract][Full Text] [Related]
11. Design of pusher-plate-type left ventricular assist device based on mechanical analyses. Hayashi K; Nakamura T; Takano H; Umezu M; Taenaka Y; Matsuda T Artif Organs; 1984 May; 8(2):204-14. PubMed ID: 6732549 [TBL] [Abstract][Full Text] [Related]
12. Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques. Nakata M; Masuzawa T; Tatsumi E; Taenaka Y; Nishimura T; Tsukiya T; Takano H; Tsuchimoto K; Ohba K ASAIO J; 1998; 44(5):M714-8. PubMed ID: 9804529 [TBL] [Abstract][Full Text] [Related]
13. Correlation of in vivo clot deposition with the flow characteristics in the 50 cc penn state artificial heart: a preliminary study. Hochareon P; Manning KB; Fontaine AA; Tarbell JM; Deutsch S ASAIO J; 2004; 50(6):537-42. PubMed ID: 15672785 [TBL] [Abstract][Full Text] [Related]
14. In vitro hemodynamic analysis of flexible artificial ventricles. Chandran KB; Lee CS; Shipkowitz T; Chen LD; Yu LS; Wurzel D Artif Organs; 1991 Oct; 15(5):420-6. PubMed ID: 1741689 [TBL] [Abstract][Full Text] [Related]
15. Investigating the functionality of diamond-like carbon films on an artificial heart diaphragm. Ohgoe Y; Takada S; Hirakuri KK; Tsuchimoto K; Homma A; Miyamatsu T; Saitou T; Friedbacher G; Tatsumi E; Taenaka Y; Fukui Y ASAIO J; 2003; 49(6):701-7. PubMed ID: 14655738 [TBL] [Abstract][Full Text] [Related]
16. A unique left-right flow imbalance compensation scheme for an implantable total artificial heart. Kung RT; Ochs B; Singh PI ASAIO Trans; 1989; 35(3):468-70. PubMed ID: 2597509 [TBL] [Abstract][Full Text] [Related]
17. Experimental investigation of the motions of the pumping diaphragm within a sac-type pneumatically driven ventricular assist device. Jin W; Clark C J Biomech; 1994 Jan; 27(1):43-55. PubMed ID: 8106535 [TBL] [Abstract][Full Text] [Related]
18. A cardiac output monitor and diagnostic unit for pneumatically driven artificial hearts. Willshaw P; Nielsen SD; Nanas J; Pichel RH; Olsen DB Artif Organs; 1984 May; 8(2):215-9. PubMed ID: 6233957 [TBL] [Abstract][Full Text] [Related]