These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
164 related articles for article (PubMed ID: 14689490)
1. Wear evaluation of cobalt-chromium alloy for use in a metal-on-metal hip prosthesis. St John KR; Zardiackas LD; Poggie RA J Biomed Mater Res B Appl Biomater; 2004 Jan; 68(1):1-14. PubMed ID: 14689490 [TBL] [Abstract][Full Text] [Related]
2. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements. Goldsmith AA; Dowson D; Isaac GH; Lancaster JG Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049 [TBL] [Abstract][Full Text] [Related]
3. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads. Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E Proc Inst Mech Eng H; 2002; 216(4):219-30. PubMed ID: 12206518 [TBL] [Abstract][Full Text] [Related]
4. Quantitative analysis of wear and wear debris from metal-on-metal hip prostheses tested in a physiological hip joint simulator. Firkins PJ; Tipper JL; Saadatzadeh MR; Ingham E; Stone MH; Farrar R; Fisher J Biomed Mater Eng; 2001; 11(2):143-57. PubMed ID: 11352113 [TBL] [Abstract][Full Text] [Related]
5. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester. Baykal D; Siskey RS; Underwood RJ; Briscoe A; Kurtz SM Clin Orthop Relat Res; 2016 Nov; 474(11):2384-2393. PubMed ID: 27457625 [TBL] [Abstract][Full Text] [Related]
6. Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces. Shepard MF; Lieberman JR; Kabo JM J Arthroplasty; 1999 Oct; 14(7):860-6. PubMed ID: 10537263 [TBL] [Abstract][Full Text] [Related]
7. Size, shape, and composition of wear particles from metal-metal hip simulator testing: effects of alloy and number of loading cycles. Catelas I; Bobyn JD; Medley JB; Krygier JJ; Zukor DJ; Huk OL J Biomed Mater Res A; 2003 Oct; 67(1):312-27. PubMed ID: 14517891 [TBL] [Abstract][Full Text] [Related]
8. A new pin-on-disk wear testing method for simulating wear of polyethylene on cobalt-chrome alloy in total hip arthroplasty. Bragdon CR; O'Connor DO; Lowenstein JD; Jasty M; Biggs SA; Harris WH J Arthroplasty; 2001 Aug; 16(5):658-65. PubMed ID: 11503127 [TBL] [Abstract][Full Text] [Related]
9. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. A prospective, randomized study. Kim YH J Bone Joint Surg Am; 2005 Aug; 87(8):1769-76. PubMed ID: 16085617 [TBL] [Abstract][Full Text] [Related]
10. The effect of different bearing surfaces on metal ion levels in urine following 28 mm metal-on-metal and 28 mm metal-on-polyethylene total hip arthroplasty. Tiusanen H; Mäkelä K; Kiilunen M; Sarantsin P; Sipola E; Pesola M Scand J Surg; 2013; 102(3):197-203. PubMed ID: 23963035 [TBL] [Abstract][Full Text] [Related]
11. Distribution of cobalt chromium wear and corrosion products and biologic reactions. Merritt K; Brown SA Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S233-43. PubMed ID: 8769337 [TBL] [Abstract][Full Text] [Related]
12. Comparison of in vitro with in vivo characteristics of wear particles from metal-metal hip implants. Catelas I; Medley JB; Campbell PA; Huk OL; Bobyn JD J Biomed Mater Res B Appl Biomater; 2004 Aug; 70(2):167-78. PubMed ID: 15264297 [TBL] [Abstract][Full Text] [Related]
13. Systemic toxicity related to metal hip prostheses. Bradberry SM; Wilkinson JM; Ferner RE Clin Toxicol (Phila); 2014; 52(8):837-47. PubMed ID: 25132471 [TBL] [Abstract][Full Text] [Related]
14. Cobalt chromium molybdenum metal combination for modular hip prostheses. Schmidt M; Weber H; Schön R Clin Orthop Relat Res; 1996 Aug; (329 Suppl):S35-47. PubMed ID: 8769321 [TBL] [Abstract][Full Text] [Related]
15. Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less. Rames RD; Stambough JB; Pashos GE; Maloney WJ; Martell JM; Clohisy JC J Arthroplasty; 2019 Jun; 34(6):1143-1149. PubMed ID: 30808529 [TBL] [Abstract][Full Text] [Related]
16. [Wear characteristics of different metal-polyethylene beating surfaces. An experimental study of a new model of knee prosthesis]. Farizon F; Aurelle JL; Rieu J; Bousquet G Rev Chir Orthop Reparatrice Appar Mot; 1996; 82(6):522-8. PubMed ID: 9122523 [TBL] [Abstract][Full Text] [Related]
17. Toxicology of wear particles of cobalt-chromium alloy metal-on-metal hip implants Part I: physicochemical properties in patient and simulator studies. Madl AK; Liong M; Kovochich M; Finley BL; Paustenbach DJ; Oberdörster G Nanomedicine; 2015 Jul; 11(5):1201-15. PubMed ID: 25744761 [TBL] [Abstract][Full Text] [Related]
18. Ceramic Wear Particles: Can They Be Retrieved In Vivo and Duplicated In Vitro? Kurtz SM; Holyoak DT; Trebše R; Randau TM; Porporati AA; Siskey RL J Arthroplasty; 2023 Sep; 38(9):1869-1876. PubMed ID: 36966889 [TBL] [Abstract][Full Text] [Related]
19. [Five million wear simulation and particle analysis of carbon-based nano-multilayer coatings titanium alloy femoral head]. Wang HR; Li J; Li ZL; Tu JP; Jin G; Su J; Wang JJ Zhonghua Yi Xue Za Zhi; 2020 Feb; 100(7):546-551. PubMed ID: 32164109 [No Abstract] [Full Text] [Related]
20. Evaluation of wear in an all-polymer total knee replacement. Part 1: laboratory testing of polyethylene on polyacetal bearing surfaces. McKellop HA; Röstlund T; Bradley G Clin Mater; 1993; 14(2):117-26. PubMed ID: 10146440 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]