These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 1469174)

  • 1. Does central venous oxygen saturation accurately reflect mixed venous oxygen saturation? Nothing is simple, unfortunately.
    Vincent JL
    Intensive Care Med; 1992; 18(7):386-7. PubMed ID: 1469174
    [No Abstract]   [Full Text] [Related]  

  • 2. Critical care algorithms. Pulmonary artery and central venous catheter monitoring.
    Armstrong RF; Bullen C; Cohen SL; Singer M; Webb AR
    Clin Intensive Care; 1990 Mar; 1(2):93-5. PubMed ID: 10150044
    [No Abstract]   [Full Text] [Related]  

  • 3. Monitoring of central venous oxygen saturation versus mixed venous oxygen saturation in critically ill patients.
    Martin C; Auffray JP; Badetti C; Perrin G; Papazian L; Gouin F
    Intensive Care Med; 1992; 18(2):101-4. PubMed ID: 1613187
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of a continuous cardiac output and mixed venous oxygen saturation catheter in critically ill surgical patients.
    Burchell SA; Yu M; Takiguchi SA; Ohta RM; Myers SA
    Crit Care Med; 1997 Mar; 25(3):388-91. PubMed ID: 9118651
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation.
    el-Masry A; Mukhtar AM; el-Sherbeny AM; Fathy M; el-Meteini M
    Anaesthesia; 2009 Apr; 64(4):378-82. PubMed ID: 19317701
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Association of physical examination with pulmonary artery catheter parameters in acute lung injury.
    Grissom CK; Morris AH; Lanken PN; Ancukiewicz M; Orme JF; Schoenfeld DA; Thompson BT;
    Crit Care Med; 2009 Oct; 37(10):2720-6. PubMed ID: 19885995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fluctuation in mixed venous oxygen saturation in critically ill medical patients: a pilot study.
    Noll ML; Fountain RL; Duncan CA; Weaver L; Osmanski VP; Halfmann S
    Am J Crit Care; 1992 Nov; 1(3):102-6. PubMed ID: 1307898
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Central venous versus mixed venous oxygen content.
    Faber T
    Acta Anaesthesiol Scand Suppl; 1995; 107():33-6. PubMed ID: 8599294
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison of central and mixed venous oxygen saturation in circulatory failure.
    Ho KM; Harding R; Chamberlain J; Bulsara M
    J Cardiothorac Vasc Anesth; 2010 Jun; 24(3):434-9. PubMed ID: 18834813
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of central venous saturation in estimating mixed venous saturation is proportional to cardiac performance among cardiac surgical patients.
    Gasparovic H; Gabelica R; Ostojic Z; Kopjar T; Petricevic M; Ivancan V; Biocina B
    J Crit Care; 2014 Oct; 29(5):828-34. PubMed ID: 24857639
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of central venous oxygen saturation to guide therapy.
    Walley KR
    Am J Respir Crit Care Med; 2011 Sep; 184(5):514-20. PubMed ID: 21177882
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Using mixed venous oxygen saturation data to trend overall oxygenation in cardiothoracic surgical patients.
    Pier AF
    Crit Care Nurs Q; 1993 Nov; 16(3):72-85. PubMed ID: 8242448
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of cardiac output on the correlation between mixed venous and central venous oxygen saturation.
    Berridge JC
    Br J Anaesth; 1992 Oct; 69(4):409-10. PubMed ID: 1419454
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Central venous blood oxygen saturation: an early, accurate measurement of volume during hemorrhage.
    Scalea TM; Holman M; Fuortes M; Baron BJ; Phillips TF; Goldstein AS; Sclafani SJ; Shaftan GW
    J Trauma; 1988 Jun; 28(6):725-32. PubMed ID: 3385813
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Perforation of the right ventricle by a pulmonary artery catheter that continues to measure cardiac output and mixed venous saturation.
    Chuang KC; Lan AK; Luk HN; Wang CS; Huang CJ; Cheng KW; Lin KC; Jawan B
    J Clin Anesth; 2005 Mar; 17(2):124-7. PubMed ID: 15809129
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Hemodynamic monitoring in childhood.
    Stopfkuchen H
    Intensive Care Med; 1989; 15 Suppl 1():S27-31. PubMed ID: 2723244
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The efficacy of central venous and pulmonary artery catheters and therapy based upon them in reducing mortality and morbidity.
    Shoemaker WC; Kram HB; Appel PL; Fleming AW
    Arch Surg; 1990 Oct; 125(10):1332-7; discussion 1337-8. PubMed ID: 2222172
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Continuous monitoring of central venous oxygen saturation (Pediasat) in pediatric patients undergoing cardiac surgery: a validation study of a new technology.
    Ranucci M; Isgrò G; De La Torre T; Romitti F; De Benedetti D; Carlucci C; Kandil H; Ballotta A
    J Cardiothorac Vasc Anesth; 2008 Dec; 22(6):847-52. PubMed ID: 18834840
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Central venous and mixed venous oxygen saturation in critically ill patients.
    Ladakis C; Myrianthefs P; Karabinis A; Karatzas G; Dosios T; Fildissis G; Gogas J; Baltopoulos G
    Respiration; 2001; 68(3):279-85. PubMed ID: 11416249
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Speed of blood withdrawal and accurate measurement of oxygen content in mixed venous blood.
    Jaschke K; Brown D; Clark A; Doull S; English A; Hoover N; Jones P; Klamm D; Odom C; Primrose B; Sollars K; Ebberts M
    Am J Crit Care; 2014 Nov; 23(6):486-93. PubMed ID: 25362672
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.