145 related articles for article (PubMed ID: 14696930)
1. Simultaneous determination of choline and acetylcholine based on a trienzyme chemiluminometric biosensor in a single line flow injection system.
Kiba N; Ito S; Tachibana M; Tani K; Koizumi H
Anal Sci; 2003 Dec; 19(12):1647-51. PubMed ID: 14696930
[TBL] [Abstract][Full Text] [Related]
2. Chemiluminometric sensor for simultaneous determination of L-glutamate and L-lysine with immobilized oxidases in a flow injection system.
Kiba N; Miwa T; Tachibana M; Tani K; Koizumi H
Anal Chem; 2002 Mar; 74(6):1269-74. PubMed ID: 11922293
[TBL] [Abstract][Full Text] [Related]
3. An acetylcholinesterase/choline oxidase-based amperometric biosensors as a liquid chromatography detector for acetylcholine and choline determination in brain tissue homogenates.
Guerrieri A; Palmisano F
Anal Chem; 2001 Jul; 73(13):2875-82. PubMed ID: 11467530
[TBL] [Abstract][Full Text] [Related]
4. Simultaneous determination of D-glucose and 3-hydroxybutyrate by chemiluminescence detection with immobilized enzymes in a flow injection system.
Kiba N; Inoue Y; Tachibana M; Tani K; Koizumi H
Anal Sci; 2003 Aug; 19(8):1203-6. PubMed ID: 12945679
[TBL] [Abstract][Full Text] [Related]
5. Acetylcholine and choline amperometric enzyme sensors characterized in vitro and in vivo.
Mitchell KM
Anal Chem; 2004 Feb; 76(4):1098-106. PubMed ID: 14961744
[TBL] [Abstract][Full Text] [Related]
6. Electrosynthesized poly(pyrrole)/poly(2-naphthol) bilayer membrane as an effective anti-interference layer for simultaneous determination of acethylcholine and choline by a dual electrode amperometric biosensor.
Guerrieri A; Lattanzio V; Palmisano F; Zambonin PG
Biosens Bioelectron; 2006 Mar; 21(9):1710-8. PubMed ID: 16169212
[TBL] [Abstract][Full Text] [Related]
7. High-performance liquid chromatography followed by peroxyoxalate chemiluminescence detection of acetylcholine and choline utilizing immobilized enzymes.
Honda K; Miyaguchi K; Nishino H; Tanaka H; Yao T; Imai K
Anal Biochem; 1986 Feb; 153(1):50-3. PubMed ID: 3516007
[TBL] [Abstract][Full Text] [Related]
8. Multienzyme microbiosensor based on electropolymerized o-phenylenediamine for simultaneous in vitro determination of acetylcholine and choline.
Khan A; Ab Ghani S
Biosens Bioelectron; 2012 Jan; 31(1):433-8. PubMed ID: 22154168
[TBL] [Abstract][Full Text] [Related]
9. Carbon fibre-based microbiosensors for in vivo measurements of acetylcholine and choline.
Schuvailo ON; Dzyadevych SV; El'skaya AV; Gautier-Sauvigné S; Csöregi E; Cespuglio R; Soldatkin AP
Biosens Bioelectron; 2005 Jul; 21(1):87-94. PubMed ID: 15967355
[TBL] [Abstract][Full Text] [Related]
10. Determination of acetylcholine and choline by flow-injection with immobilized enzymes and fluorometric or luminometric detection.
Rícný J; Coupek J; Tucek S
Anal Biochem; 1989 Feb; 176(2):221-7. PubMed ID: 2742118
[TBL] [Abstract][Full Text] [Related]
11. An enzyme-reactor for electrochemical monitoring of choline and acetylcholine: applications in high-performance liquid chromatography, brain tissue, microdialysis and cerebrospinal fluid.
Flentge F; Venema K; Koch T; Korf J
Anal Biochem; 1992 Aug; 204(2):305-10. PubMed ID: 1443528
[TBL] [Abstract][Full Text] [Related]
12. Development of an acetylcholinesterase-choline oxidase based biosensor for acetylcholine determination.
Tunç AT; Aynacı Koyuncu E; Arslan F
Artif Cells Nanomed Biotechnol; 2016 Nov; 44(7):1659-64. PubMed ID: 26367252
[TBL] [Abstract][Full Text] [Related]
13. Amperometric sensors for peroxide, choline, and acetylcholine based on electron transfer between horseradish peroxidase and a redox polymer.
Garguilo MG; Huynh N; Proctor A; Michael AC
Anal Chem; 1993 Mar; 65(5):523-8. PubMed ID: 8452244
[TBL] [Abstract][Full Text] [Related]
14. A new microdialysis-electrochemical device for in vivo simultaneous determination of acetylcholine and choline in rat brain treated with N-methyl-(R)-salsolinol.
Zhu W; An Y; Zheng J; Tang L; Zhang W; Jin L; Jiang L
Biosens Bioelectron; 2009 Aug; 24(12):3594-9. PubMed ID: 19523811
[TBL] [Abstract][Full Text] [Related]
15. On-line electrochemical sensor for selective continuous measurement of acetylcholine in cultured brain tissue.
Niwa O; Horiuchi T; Kurita R; Torimitsu K
Anal Chem; 1998 Mar; 70(6):1126-32. PubMed ID: 9530003
[TBL] [Abstract][Full Text] [Related]
16. Choline and acetylcholine detection based on peroxidase-like activity and protein antifouling property of platinum nanoparticles in bovine serum albumin scaffold.
He SB; Wu GW; Deng HH; Liu AL; Lin XH; Xia XH; Chen W
Biosens Bioelectron; 2014 Dec; 62():331-6. PubMed ID: 25038538
[TBL] [Abstract][Full Text] [Related]
17. Development of choline and acetylcholine Pt microelectrodes.
Huang Z; Villarta-Snow R; Lubrano GJ; Guilbault GG
Anal Biochem; 1993 Nov; 215(1):31-7. PubMed ID: 8297012
[TBL] [Abstract][Full Text] [Related]
18. Simple determination of acetylcholine and choline within 4 min by HPLC-ECD and immobilized enzyme column in mice brain areas.
Murai S; Miyate H; Saito H; Nagahama H; Masuda Y; Itoh T
J Pharmacol Methods; 1989 Jul; 21(4):255-62. PubMed ID: 2547119
[TBL] [Abstract][Full Text] [Related]
19. [Determination of acetylcholine and choline in microdialysates from rat brain by high performance liquid chromatography with electrochemical detection combined with a post-column immobilized enzyme reactor].
Ye W; Ma X; Mei Z
Se Pu; 1998 Sep; 16(5):375-8. PubMed ID: 11498913
[TBL] [Abstract][Full Text] [Related]
20. Flow-through chemiluminescence sensor using immobilized oxidases for the selective determination of L-glutamate in a flow-injection system.
Kiba N; Ito S; Tachibana M; Tani K; Koizumi H
Anal Sci; 2001 Aug; 17(8):929-33. PubMed ID: 11708095
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]