BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

102 related articles for article (PubMed ID: 1470644)

  • 1. A feasibility study of the in vivo measurement of aluminium in peripheral bone.
    Green S; Chettle DR
    Phys Med Biol; 1992 Dec; 37(12):2287-96. PubMed ID: 1470644
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo measurement of bone aluminium: recent developments.
    Pejović-Milić A; Byun SH; Comsa DC; McNeill FE; Prestwich WV; Chettle DR
    J Inorg Biochem; 2005 Sep; 99(9):1899-903. PubMed ID: 16043224
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Characteristics of an accelerator based system for in vivo aluminium measurement in peripheral bone.
    Green S; Bradley DA; Mountford PJ; Morgan WD; Chettle DR; Weaver DR
    Basic Life Sci; 1993; 60():289-93. PubMed ID: 8110130
    [No Abstract]   [Full Text] [Related]  

  • 4. In vivo measurement of bone aluminum in population living in southern Ontario, Canada.
    Davis K; Aslam ; Pejović-Milić A; Chettle DR
    Med Phys; 2008 Nov; 35(11):5115-23. PubMed ID: 19070246
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Noninvasive measurement of aluminium in human bone: preliminary human study and improved system performance.
    Aslam ; Davis K; Pejović-Milić A; Chettle DR
    J Inorg Biochem; 2009 Nov; 103(11):1585-90. PubMed ID: 19740544
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The study of in vivo quantification of aluminum (Al) in human bone with a compact DD generator-based neutron activation analysis (NAA) system.
    Byrne P; Mostafaei F; Liu Y; Blake SP; Koltick D; Nie LH
    Physiol Meas; 2016 May; 37(5):649-60. PubMed ID: 27093035
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Reactor neutron activation analysis for aluminium in the presence of phosphorus and silicon. Contributions of 28Al activities from 31P(n, alpha) 28Al and 28Si(n, p) 28Al reactions].
    Mizumoto Y; Iwata S; Sasajima K; Yoshimasu F; Yase Y
    Radioisotopes; 1984 Jan; 33(1):8-14. PubMed ID: 6739855
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of spectral decomposition analysis to in vivo quantification of aluminum by neutron activation analysis.
    Comsa DC; Prestwich WV; McNeill FE; Byun SH
    Appl Radiat Isot; 2004 Dec; 61(6):1353-60. PubMed ID: 15388133
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Non-destructive neutron activation analysis of aluminium and phosphorus in bone biopsies.
    Gatschke W; Gawlik D; Kraft D
    J Clin Chem Clin Biochem; 1980 Jul; 18(7):403-6. PubMed ID: 7411021
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The development of a technique to measure bone aluminium content using neutron activation analysis.
    Wyatt RM; Ryde SJ; Morgan WD; McNeil EA; Hainsworth IR; Williams AJ
    Physiol Meas; 1993 Aug; 14(3):327-35. PubMed ID: 8401272
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improvements in an in vivo neutron activation analysis (NAA) method for the measurement of fluorine in human bone.
    Mostafaei F; McNeill FE; Chettle DR; Prestwich WV
    Physiol Meas; 2013 Oct; 34(10):1329-41. PubMed ID: 24045335
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Feasibility of measuring selenium in humans using in vivo neutron activation analysis.
    Tahir SN; Chettle DR; Byun SH; Prestwich WV
    Physiol Meas; 2015 Nov; 36(11):2217-30. PubMed ID: 26393663
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Development of an accelerator based determination of aluminum burden in peripheral bone by neutron activation analysis.
    Pejovic-Milic A; Mcneill FE; Prestwich WV; Waker AJ; Chettle DR
    Appl Radiat Isot; 1998; 49(5-6):717-9. PubMed ID: 9569589
    [No Abstract]   [Full Text] [Related]  

  • 14. Development of an in vivo neutron activation analysis technique to measure bone aluminum.
    Wyatt RM; Ryde SJ; Williams AJ; Evans CJ; McNeil EA; Morgan WD
    Basic Life Sci; 1993; 60():319-21. PubMed ID: 8110137
    [No Abstract]   [Full Text] [Related]  

  • 15. A system for in vivo measurement of bone calcium by local neutron activation of the hand.
    Ebifegha ME; Harrison JE; McNeill KG; Krishnan SS; Ssengabi J
    Int J Rad Appl Instrum A; 1986; 37(2):159-64. PubMed ID: 3019928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Compact DD generator-based neutron activation analysis (NAA) system to determine fluorine in human bone in vivo: a feasibility study.
    Mostafaei F; Blake SP; Liu Y; Sowers DA; Nie LH
    Physiol Meas; 2015 Oct; 36(10):2057-67. PubMed ID: 26289795
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo design study of a moderated 252Cf source for in vivo neutron activation analysis of aluminium.
    Lewis DG; Natto SS; Ryde SJ; Evans CJ
    Phys Med Biol; 1997 Apr; 42(4):625-36. PubMed ID: 9127441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pilot studies for in vivo bone aluminum measurements.
    Palerme S; Chettle DR; Kennett TJ; Prestwich WV; Webber CE
    Basic Life Sci; 1993; 60():303-6. PubMed ID: 8110133
    [No Abstract]   [Full Text] [Related]  

  • 19. Measurement accuracy of aluminium content in bone.
    Hellström HO; Lindh U; Mjöberg B
    Ups J Med Sci; 2000; 105(1):67-71. PubMed ID: 10893054
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The feasibility of in vivo quantification of bone-fluorine in humans by delayed neutron activation analysis: a pilot study.
    Chamberlain M; Gräfe JL; Byun SH; Chettle DR; Egden LM; Orchard GM; Webber CE; McNeill FE
    Physiol Meas; 2012 Feb; 33(2):243-57. PubMed ID: 22273740
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.