These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 14722632)

  • 1. Accuracy of pulse oximetry readings in an animal model of low perfusion caused by emerging pneumonia and sepsis.
    Hummler HD; Engelmann A; Pohlandt F; Högel J; Franz AR
    Intensive Care Med; 2004 Apr; 30(4):709-13. PubMed ID: 14722632
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pulse oximetry during low perfusion caused by emerging pneumonia and sepsis in rabbits.
    Hummler HD; Pohlandt F; Franz AR
    Crit Care Med; 2002 Nov; 30(11):2501-8. PubMed ID: 12441761
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Decreased accuracy of pulse oximetry measurements during low perfusion caused by sepsis: Is the perfusion index of any value?
    Hummler HD; Engelmann A; Pohlandt F; Högel J; Franz AR
    Intensive Care Med; 2006 Sep; 32(9):1428-31. PubMed ID: 16810522
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reliability of conventional and new pulse oximetry in neonatal patients.
    Hay WW; Rodden DJ; Collins SM; Melara DL; Hale KA; Fashaw LM
    J Perinatol; 2002; 22(5):360-6. PubMed ID: 12082469
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The precision and accuracy of Nellcor and Masimo oximeters at low oxygen saturations (70%) in newborn lambs.
    Dawson JA; Bastrenta P; Cavigioli F; Thio M; Ong T; Siew ML; Hooper SB; Davis PG
    Arch Dis Child Fetal Neonatal Ed; 2014 Jul; 99(4):F278-81. PubMed ID: 24596406
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance of three new-generation pulse oximeters during motion and low perfusion in volunteers.
    Shah N; Ragaswamy HB; Govindugari K; Estanol L
    J Clin Anesth; 2012 Aug; 24(5):385-91. PubMed ID: 22626683
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of a third (Dolphin Voyager) versus first generation pulse oximeter (Nellcor N-180) in predicting arterial oxygen saturation and pulse rate in the anesthetized dog.
    Burns PM; Driessen B; Boston R; Gunther RA
    Vet Anaesth Analg; 2006 Sep; 33(5):281-95. PubMed ID: 16916350
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Discrepancies between arterial oxygen saturation and functional oxygen saturation measured with pulse oximetry in very preterm infants.
    Rosychuk RJ; Hudson-Mason A; Eklund D; Lacaze-Masmonteil T
    Neonatology; 2012; 101(1):14-9. PubMed ID: 21791935
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Accuracy of Pulse Oximeters Intended for Hypoxemic Pediatric Patients.
    Harris BU; Char DS; Feinstein JA; Verma A; Shiboski SC; Ramamoorthy C
    Pediatr Crit Care Med; 2016 Apr; 17(4):315-20. PubMed ID: 26914626
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE; Mannheimer PD
    Anesth Analg; 2010 Jul; 111(1):143-8. PubMed ID: 20007731
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Improved accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR; Bickler PE
    Anesth Analg; 2010 Nov; 111(5):1160-7. PubMed ID: 20841412
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of forehead and digit oximetry in surgical/trauma patients at risk for decreased peripheral perfusion.
    Schallom L; Sona C; McSweeney M; Mazuski J
    Heart Lung; 2007; 36(3):188-94. PubMed ID: 17509425
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of Masimo signal extraction technology pulse oximetry in anaesthetized pregnant sheep.
    Quinn CT; Raisis AL; Musk GC
    Vet Anaesth Analg; 2013 Mar; 40(2):149-56. PubMed ID: 22978823
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A prospective comparison of 3 new-generation pulse oximetry devices during ambulation after open heart surgery.
    Richards NM; Giuliano KK; Jones PG
    Respir Care; 2006 Jan; 51(1):29-35. PubMed ID: 16381614
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of pulse oximeters at low oxygen saturations in children with congenital cyanotic heart disease: An observational study.
    Kim EH; Lee JH; Song IK; Kim HS; Jang YE; Yoo S; Kim JT
    Paediatr Anaesth; 2019 Jun; 29(6):597-603. PubMed ID: 30938906
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Validity of pulse oximetry during maximal exercise in normoxia, hypoxia, and hyperoxia.
    Yamaya Y; Bogaard HJ; Wagner PD; Niizeki K; Hopkins SR
    J Appl Physiol (1985); 2002 Jan; 92(1):162-8. PubMed ID: 11744656
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparative analysis of signal accuracy of three SpO
    Giuliano KK; Bilkovski RN; Beard J; Lamminmäki S
    J Clin Monit Comput; 2023 Dec; 37(6):1451-1461. PubMed ID: 37266709
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Operational evaluation of pulse oximetry in NICU patients with arterial access.
    Gerstmann D; Berg R; Haskell R; Brower C; Wood K; Yoder B; Greenway L; Lassen G; Ogden R; Stoddard R; Minton S
    J Perinatol; 2003; 23(5):378-83. PubMed ID: 12847532
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.
    Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D
    J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effects of motion artifact and low perfusion on the performance of a new generation of pulse oximeters in volunteers undergoing hypoxemia.
    Gehring H; Hornberger C; Matz H; Konecny E; Schmucker P
    Respir Care; 2002 Jan; 47(1):48-60. PubMed ID: 11749687
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.