111 related articles for article (PubMed ID: 14728955)
21. Locking compression plates for osteoporotic nonunions of the diaphyseal humerus.
Ring D; Kloen P; Kadzielski J; Helfet D; Jupiter JB
Clin Orthop Relat Res; 2004 Aug; (425):50-4. PubMed ID: 15292787
[TBL] [Abstract][Full Text] [Related]
22. [Internal screwed plate for recent fractures of the humeral diaphysis in adults].
Dayez J
Rev Chir Orthop Reparatrice Appar Mot; 1999 Jun; 85(3):238-44. PubMed ID: 10422129
[TBL] [Abstract][Full Text] [Related]
23. [Comparison of plate-screw fixation and intramedullary fixation with inflatable nails in the treatment of acute humeral shaft fractures].
Dağlar B; Delialioğlu OM; Taşbaş BA; Bayrakçi K; Ağar M; Günel U
Acta Orthop Traumatol Turc; 2007; 41(1):7-14. PubMed ID: 17483630
[TBL] [Abstract][Full Text] [Related]
24. Comparison of three different treatment modalities in the management of humeral shaft nonunions (plates, unilateral, and circular external fixators).
Atalar AC; Kocaoglu M; Demirhan M; Bilsel K; Eralp L
J Orthop Trauma; 2008 Apr; 22(4):248-57. PubMed ID: 18404034
[TBL] [Abstract][Full Text] [Related]
25. Open reduction and fixation with a locking plate without bone grafting is a reasonable and safe option for treating proximal humerus nonunion.
Quadlbauer S; Hofmann GJ; Leixnering M; Rosenauer R; Hausner T; Reichetseder J
Int Orthop; 2018 Sep; 42(9):2199-2209. PubMed ID: 29442159
[TBL] [Abstract][Full Text] [Related]
26. Internal fixation of fractures and non-unions of the humeral shaft. Indications and results in a multi-center study.
Foster RJ; Dixon GL; Bach AW; Appleyard RW; Green TM
J Bone Joint Surg Am; 1985 Jul; 67(6):857-64. PubMed ID: 4019533
[TBL] [Abstract][Full Text] [Related]
27. Non-union of the humeral shaft treated by internal fixation.
Kumar A; Sadiq SA
Int Orthop; 2002; 26(4):214-6. PubMed ID: 12185522
[TBL] [Abstract][Full Text] [Related]
28. The use of a blade plate and autogenous cancellous bone graft in the treatment of ununited fractures of the proximal humerus.
Ring D; McKee MD; Perey BH; Jupiter JB
J Shoulder Elbow Surg; 2001; 10(6):501-7. PubMed ID: 11743526
[TBL] [Abstract][Full Text] [Related]
29. [Effectiveness comparison between locking compression plate fixation and locked intramedullary nail fixation for humeral shaft fracture of types B and C].
Yin P; Mao Z; Zhang L; Tao S; Zhang Q; Liang X; Zhang H; Long A; Wang G; Tang P
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1457-61. PubMed ID: 24640365
[TBL] [Abstract][Full Text] [Related]
30. Long-term follow-up of persistent humeral shaft non-unions treated with tricortical bone grafting and compression plating.
Billings A; Coleman SS
Iowa Orthop J; 1999; 19():31-4. PubMed ID: 10847514
[TBL] [Abstract][Full Text] [Related]
31. Revision with dynamic compression plate and cancellous bone graft for aseptic nonunion after surgical treatment of humeral shaft fracture.
Lin CL; Fang CK; Chiu FY; Chen CM; Chen TH
J Trauma; 2009 Dec; 67(6):1393-6. PubMed ID: 20009693
[TBL] [Abstract][Full Text] [Related]
32. Anterior approach in humeral plating osteosynthesis.
Handy Eone D; Ngono PCD; Essi MJ; Leckpa G; Muluem KO; Ibrahima F; Sosso MA
Orthop Traumatol Surg Res; 2018 Oct; 104(6):847-851. PubMed ID: 29777778
[TBL] [Abstract][Full Text] [Related]
33. The open reduction and internal fixation of humeral diaphysis fracture treatment with a medial approach.
Wilairatana V; Prasongchin P
J Med Assoc Thai; 2001 Jun; 84 Suppl 1():S423-7. PubMed ID: 11529369
[TBL] [Abstract][Full Text] [Related]
34. Open reduction and internal fixation of delayed union and nonunion of the distal humerus.
Sanders RA; Sackett JR
J Orthop Trauma; 1990; 4(3):254-9. PubMed ID: 2231121
[TBL] [Abstract][Full Text] [Related]
35. Minimally invasive plate osteosynthesis for humeral shaft fracture: a reproducible technique with the assistance of an external fixator.
Lee HJ; Oh CW; Oh JK; Apivatthakakul T; Kim JW; Yoon JP; Lee DJ; Jung JW
Arch Orthop Trauma Surg; 2013 May; 133(5):649-57. PubMed ID: 23463256
[TBL] [Abstract][Full Text] [Related]
36. Treatment of humeral shaft delayed unions and nonunions with humeral locked nails.
Lin J; Hou SM; Hang YS
J Trauma; 2000 Apr; 48(4):695-703. PubMed ID: 10780604
[TBL] [Abstract][Full Text] [Related]
37. Treatment of non-union of the humerus using the Orthofix external fixator.
Lavini F; Renzi Brivio L; Pizzoli A; Giotakis N; Bartolozzi P
Injury; 2001 Dec; 32 Suppl 4():SD35-40. PubMed ID: 11812477
[TBL] [Abstract][Full Text] [Related]
38. Management of nonunions of the proximal humeral diaphysis.
Prasarn ML; Achor T; Paul O; Lorich DG; Helfet DL
Injury; 2010 Dec; 41(12):1244-8. PubMed ID: 20452590
[TBL] [Abstract][Full Text] [Related]
39. Plate osteosynthesis of fractures of the shaft of the humerus: comparison of limited contact dynamic compression plates and locking compression plates.
Singh AK; Narsaria N; Seth RR; Garg S
J Orthop Traumatol; 2014 Jun; 15(2):117-22. PubMed ID: 24687559
[TBL] [Abstract][Full Text] [Related]
40. Atrophic nonunion of humeral diaphysis treated with locking plate and recombinant bone morphogenetic protein: nine cases.
Crawford CH; Seligson D
Am J Orthop (Belle Mead NJ); 2009 Nov; 38(11):567-70. PubMed ID: 20049351
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]