122 related articles for article (PubMed ID: 14737767)
1. Effects of the initial temperature of acrylic bone cement liquid monomer on the properties of the stem-cement interface and cement polymerization.
Iesaka K; Jaffe WL; Kummer FJ
J Biomed Mater Res B Appl Biomater; 2004 Feb; 68(2):186-90. PubMed ID: 14737767
[TBL] [Abstract][Full Text] [Related]
2. Precooling of the femoral canal enhances shear strength at the cement-prosthesis interface and reduces the polymerization temperature.
Hsieh PH; Tai CL; Chang YH; Lee MS; Shih HN; Shih CH
J Orthop Res; 2006 Sep; 24(9):1809-14. PubMed ID: 16865715
[TBL] [Abstract][Full Text] [Related]
3. Effects of preheating of hip prostheses on the stem-cement interface.
Iesaka K; Jaffe WL; Kummer FJ
J Bone Joint Surg Am; 2003 Mar; 85(3):421-7. PubMed ID: 12637425
[TBL] [Abstract][Full Text] [Related]
4. Effect of stem preheating and precooling on residual stress formation at stem/cement interface for cemented hip implants.
Madrala A; Nuño N
J Biomed Mater Res B Appl Biomater; 2010 Apr; 93(1):258-65. PubMed ID: 20091924
[TBL] [Abstract][Full Text] [Related]
5. Integrity of the stem-cement interface in THA: effects of stem surface finish and cement porosity.
Iesaka K; Jaffe WL; Kummer FJ
J Biomed Mater Res B Appl Biomater; 2008 Oct; 87(1):77-82. PubMed ID: 18386841
[TBL] [Abstract][Full Text] [Related]
6. Does stem preheating have a beneficial effect on PMMA bulk porosity in cemented THA?
Madrala A; Nuño N; Bureau MN
J Biomed Mater Res B Appl Biomater; 2010 Oct; 95(1):1-8. PubMed ID: 20737585
[TBL] [Abstract][Full Text] [Related]
7. [Effects of low-frequency pulsed wave ultrasound on the shear properties of the interface of vancomycin-loaded acrylic bone cement-stem].
Zhao QH; Zhu FB; Cai XZ; Yan SG; He RX
Zhonghua Yi Xue Za Zhi; 2017 Feb; 97(7):545-550. PubMed ID: 28260297
[No Abstract] [Full Text] [Related]
8. The effects of fluid penetration and interfacial porosity on the fixation of cemented femoral components.
Iesaka K; Jaffe WL; Jones CM; Kummer FJ
J Bone Joint Surg Br; 2005 Sep; 87(9):1298-302. PubMed ID: 16129762
[TBL] [Abstract][Full Text] [Related]
9. Effect of storage temperature and equilibration time on polymethyl methacrylate (PMMA) bone cement polymerization in joint replacement surgery.
Koh BT; Tan JH; Ramruttun AK; Wang W
J Orthop Surg Res; 2015 Nov; 10():178. PubMed ID: 26577581
[TBL] [Abstract][Full Text] [Related]
10. Thermally induced strains and total shrinkage of the polymethyl-methacrylate cement in simplified models of total hip arthroplasty.
Griza S; Ueki MM; Souza DH; Cervieri A; Strohaecker TR
J Mech Behav Biomed Mater; 2013 Feb; 18():29-36. PubMed ID: 23237878
[TBL] [Abstract][Full Text] [Related]
11. Static shear strength between polished stem and seven commercial acrylic bone cements.
Zhang H; Brown L; Blunt L
J Mater Sci Mater Med; 2008 Feb; 19(2):591-9. PubMed ID: 17619954
[TBL] [Abstract][Full Text] [Related]
12. Cemented fixation with PMMA or Bis-GMA resin hydroxyapatite cement: effect of implant surface roughness.
Walsh WR; Svehla MJ; Russell J; Saito M; Nakashima T; Gillies RM; Bruce W; Hori R
Biomaterials; 2004 Sep; 25(20):4929-34. PubMed ID: 15109853
[TBL] [Abstract][Full Text] [Related]
13. Theoretical prediction and experimental determination of the effect of mold characteristics on temperature and monomer conversion fraction profiles during polymerization of a PMMA-based bone cement.
Vallo CI
J Biomed Mater Res; 2002; 63(5):627-42. PubMed ID: 12209910
[TBL] [Abstract][Full Text] [Related]
14. Modification of Mechanical Properties, Polymerization Temperature, and Handling Time of Polymethylmethacrylate Cement for Enhancing Applicability in Vertebroplasty.
Tai CL; Lai PL; Lin WD; Tsai TT; Lee YC; Liu MY; Chen LH
Biomed Res Int; 2016; 2016():7901562. PubMed ID: 27812530
[TBL] [Abstract][Full Text] [Related]
15. Bone marrow modified acrylic bone cement for augmentation of osteoporotic cancellous bone.
Arens D; Rothstock S; Windolf M; Boger A
J Mech Behav Biomed Mater; 2011 Nov; 4(8):2081-9. PubMed ID: 22098908
[TBL] [Abstract][Full Text] [Related]
16. Porosity reduction in bone cement at the cement-stem interface.
Bishop NE; Ferguson S; Tepic S
J Bone Joint Surg Br; 1996 May; 78(3):349-56. PubMed ID: 8636165
[TBL] [Abstract][Full Text] [Related]
17. Factors affecting the static shear strength of the prosthetic stem-bone cement interface.
Wang JS; Taylor M; Flivik G; Lidgren L
J Mater Sci Mater Med; 2003 Jan; 14(1):55-61. PubMed ID: 15348539
[TBL] [Abstract][Full Text] [Related]
18. Influence of femoral stem surface finish on the apparent static shear strength at the stem-cement interface.
Zhang H; Brown LT; Blunt LA; Barrans SM
J Mech Behav Biomed Mater; 2008 Jan; 1(1):96-104. PubMed ID: 19627775
[TBL] [Abstract][Full Text] [Related]
19. The clinical significance of vacuum mixing bone cement.
Geiger MH; Keating EM; Ritter MA; Ginther JA; Faris PM; Meding JB
Clin Orthop Relat Res; 2001 Jan; (382):258-66. PubMed ID: 11153996
[TBL] [Abstract][Full Text] [Related]
20. Flexural properties of crosslinked and oligomer-modified glass-fibre reinforced acrylic bone cement.
Puska MA; Närhi TO; Aho AJ; Yli-Urpo A; Vallittu PK
J Mater Sci Mater Med; 2004 Sep; 15(9):1037-43. PubMed ID: 15448412
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]