These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Structural changes in glutaraldehyde-treated porcine heterografts used as substitute cardiac valves. Transmission and scanning electron microscopic observations in 12 patients. Ferrans VJ; Spray TL; Billingham ME; Roberts WC Am J Cardiol; 1978 Jun; 41(7):1159-84. PubMed ID: 96684 [TBL] [Abstract][Full Text] [Related]
3. A morphologic overview of the porcine bioprosthetic valve--before and after its degeneration. Riddle JM; Jennings JJ; Stein PD; Magilligan DJ Scan Electron Microsc; 1984; (Pt 1):207-14. PubMed ID: 6740225 [TBL] [Abstract][Full Text] [Related]
4. Effects of fixation back pressure and antimineralization treatment on the morphology of porcine aortic bioprosthetic valves. Flomenbaum MA; Schoen FJ J Thorac Cardiovasc Surg; 1993 Jan; 105(1):154-64. PubMed ID: 8419696 [TBL] [Abstract][Full Text] [Related]
5. Surface morphology of degenerated porcine bioprosthetic valves four to seven years following implantation. Riddle JM; Magilligan DJ; Stein PD J Thorac Cardiovasc Surg; 1981 Feb; 81(2):279-87. PubMed ID: 7453238 [TBL] [Abstract][Full Text] [Related]
9. Successful endothelialization of porcine glutaraldehyde-fixed aortic valves in a heterotopic sheep model. Gulbins H; Pritisanac A; Pieper K; Goldemund A; Meiser BM; Reichart B; Daebritz S Ann Thorac Surg; 2006 Apr; 81(4):1472-9. PubMed ID: 16564295 [TBL] [Abstract][Full Text] [Related]
10. [Hemodynamic performance of newly developed composite stentless porcine aortic valve: in vitro testing and in vivo experiment with sheep]. Song GM; Zhou JY; Hu SS; Cui JW; Song YH; Tang Y; Zhang Y; Jiang H; Yuan WM; Song XY Zhonghua Yi Xue Za Zhi; 2008 Jul; 88(29):2059-63. PubMed ID: 19080436 [TBL] [Abstract][Full Text] [Related]
11. Novel method of decellularization of porcine valves using polyethylene glycol and gamma irradiation. Ota T; Taketani S; Iwai S; Miyagawa S; Furuta M; Hara M; Uchimura E; Okita Y; Sawa Y Ann Thorac Surg; 2007 Apr; 83(4):1501-7. PubMed ID: 17383366 [TBL] [Abstract][Full Text] [Related]
12. St Jude Epic heart valve bioprostheses versus native human and porcine aortic valves - comparison of mechanical properties. Kalejs M; Stradins P; Lacis R; Ozolanta I; Pavars J; Kasyanov V Interact Cardiovasc Thorac Surg; 2009 May; 8(5):553-6. PubMed ID: 19190025 [TBL] [Abstract][Full Text] [Related]
13. Deterioration of formalin-treated aortic valve heterografts. Buch WS; Kosek JC; Angell WW; Shumway SE J Thorac Cardiovasc Surg; 1970 Nov; 60(5):673-82. PubMed ID: 5475219 [No Abstract] [Full Text] [Related]
14. Extracellular matrix degrading enzymes are active in porcine stentless aortic bioprosthetic heart valves. Simionescu DT; Lovekamp JJ; Vyavahare NR J Biomed Mater Res A; 2003 Sep; 66(4):755-63. PubMed ID: 12926026 [TBL] [Abstract][Full Text] [Related]
15. [Construction of a tissue-engineered valve with decellular porcine aortic valve scaffold in the abdominal aorta of canine]. Liu WY; Zhao DE; Jin ZX; Gu CH; Tan HM Zhonghua Wai Ke Za Zhi; 2005 Mar; 43(6):366-9. PubMed ID: 15854341 [TBL] [Abstract][Full Text] [Related]
16. In vivo study of the effects of cryopreservation on heart valve xenotransplantation. Nagasaka S; Taniguchi S; Nakayama Y; Sakaguchi H; Nishizaki K; Naito H; Morioka H Cardiovasc Pathol; 2005; 14(2):70-9. PubMed ID: 15780798 [TBL] [Abstract][Full Text] [Related]
17. The decellularized porcine heart valve matrix in tissue engineering: platelet adhesion and activation. Kasimir MT; Weigel G; Sharma J; Rieder E; Seebacher G; Wolner E; Simon P Thromb Haemost; 2005 Sep; 94(3):562-7. PubMed ID: 16268473 [TBL] [Abstract][Full Text] [Related]
18. Inflammation and infection in nine surgically explanted Medtronic Freestyle stentless aortic valves. Butany J; Zhou T; Leong SW; Cunningham KS; Thangaroopan M; Jegatheeswaran A; Feindel C; David TE Cardiovasc Pathol; 2007; 16(5):258-67. PubMed ID: 17868876 [TBL] [Abstract][Full Text] [Related]
19. Structural alterations of the porcine heterograft after various durations of implantation. Ashraf M; Bloor CM Am J Cardiol; 1978 Jun; 41(7):1185-90. PubMed ID: 96685 [TBL] [Abstract][Full Text] [Related]
20. [Surface changes of the pulmonary valve following pulmonary valve xenotransplantation in the descending aorta. An experimental study in dogs]. Geroulanos S; Turina M; Senning A Chir Forum Exp Klin Forsch; 1979; ():23-7. PubMed ID: 110559 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]