212 related articles for article (PubMed ID: 14743485)
1. High-resolution computer simulation of the dynamics of isoelectric focusing of proteins.
Thormann W; Huang T; Pawliszyn J; Mosher RA
Electrophoresis; 2004 Jan; 25(2):324-37. PubMed ID: 14743485
[TBL] [Abstract][Full Text] [Related]
2. High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: the post-separation stabilizing phase revisited.
Mosher RA; Thormann W
Electrophoresis; 2002 Jun; 23(12):1803-14. PubMed ID: 12116123
[TBL] [Abstract][Full Text] [Related]
3. High-resolution computer simulation of the dynamics of isoelectric focusing using carrier ampholytes: focusing with concurrent electrophoretic mobilization is an isotachophoretic process.
Thormann W; Mosher RA
Electrophoresis; 2006 Mar; 27(5-6):968-83. PubMed ID: 16523465
[TBL] [Abstract][Full Text] [Related]
4. Dynamics of capillary isoelectric focusing in the absence of fluid flow: high-resolution computer simulation and experimental validation with whole column optical imaging.
Mao Q; Pawliszyn J; Thormann W
Anal Chem; 2000 Nov; 72(21):5493-502. PubMed ID: 11080905
[TBL] [Abstract][Full Text] [Related]
5. High-resolution computer simulation of electrophoretic mobilization in isoelectric focusing.
Thormann W; Mosher RA
Electrophoresis; 2008 Apr; 29(8):1676-86. PubMed ID: 18383018
[TBL] [Abstract][Full Text] [Related]
6. High-resolution computer simulation of the dynamics of isoelectric focusing: in quest of more realistic input parameters for carrier ampholytes.
Mosher RA; Thormann W
Electrophoresis; 2008 Mar; 29(5):1036-47. PubMed ID: 18219653
[TBL] [Abstract][Full Text] [Related]
7. Effects of ampholyte concentration on protein behavior in on-chip isoelectric focusing.
Shim J; Dutta P; Ivory CF
Electrophoresis; 2008 Mar; 29(5):1026-35. PubMed ID: 18257108
[TBL] [Abstract][Full Text] [Related]
8. Conductivity properties of carrier ampholyte pH gradients in isoelectric focusing.
Stoyanov AV; Das C; Fredrickson CK; Fan ZH
Electrophoresis; 2005 Jan; 26(2):473-9. PubMed ID: 15657903
[TBL] [Abstract][Full Text] [Related]
9. Recent developments in capillary isoelectric focusing with whole-column imaging detection.
Fang X; Tragas C; Wu J; Mao Q; Pawliszyn J
Electrophoresis; 1998 Oct; 19(13):2290-5. PubMed ID: 9788311
[TBL] [Abstract][Full Text] [Related]
10. Characterization of genetic variants of human serum transferrin by isoelectric focusing: comparison between conventional and immobilized pH gradients, and application to a protocol for paternity testing.
Pascali VL; Dobosz M; Destro-Bisol G; D'Aloja E
Electrophoresis; 1988 Aug; 9(8):411-7. PubMed ID: 3234383
[TBL] [Abstract][Full Text] [Related]
11. Single-input divergent flow IEF for preparative analysis of proteins.
Stastna M; Slais K
Electrophoresis; 2008 Nov; 29(22):4503-7. PubMed ID: 18985663
[TBL] [Abstract][Full Text] [Related]
12. Native protein blotting after isoelectric focusing in fabric reinforced polyacrylamide gels in carrier ampholyte generated or immobilized pH gradients.
Kinzkofer-Peresch A; Patestos NP; Fauth M; Kögel F; Zok R; Radola BJ
Electrophoresis; 1988 Sep; 9(9):497-511. PubMed ID: 3243247
[TBL] [Abstract][Full Text] [Related]
13. Effects of ampholyte dissociation constants on protein separation in on-chip isoelectric focusing.
Shim J; Dutta P; Ivory CF
J Nanosci Nanotechnol; 2008 Jul; 8(7):3719-28. PubMed ID: 19051929
[TBL] [Abstract][Full Text] [Related]
14. Isoelectric focusing in immobilized pH gradients with carrier ampholytes added for high-resolution phenotyping of bovine beta-lactoglobulins: characterization of a new genetic variant.
Krause I; Buchberger J; Weiss G; Pflügler M; Klostermeyer H
Electrophoresis; 1988 Sep; 9(9):609-13. PubMed ID: 3243259
[TBL] [Abstract][Full Text] [Related]
15. Development of a simple ampholyte-free isoelectric focusing slab electrophoresis for protein fractionation.
Zhan Y; Lemma T; Musteata MF; Pawliszyn J
J Chromatogr A; 2009 Apr; 1216(14):2928-33. PubMed ID: 18752802
[TBL] [Abstract][Full Text] [Related]
16. Electrically controlled focusing of proteins and ampholytes between two modified electrolytes. Computer simulation.
Deml M; Pospíchal J
Appl Theor Electrophor; 1994; 4(3):107-15. PubMed ID: 7612692
[TBL] [Abstract][Full Text] [Related]
17. Dispersion of protein bands in a horseshoe microchannel during IEF.
Shim J; Dutta P; Ivory CF
Electrophoresis; 2009 Mar; 30(5):723-31. PubMed ID: 19260007
[TBL] [Abstract][Full Text] [Related]
18. Carrier ampholytes rehabilitated: gel isoelectric focusing on pH gradients visualized in real-time by automated fluorescence scanning in the HPGE-1000 apparatus.
Gombocz E; Cortez E
Electrophoresis; 1999 Jun; 20(7):1365-72. PubMed ID: 10424457
[TBL] [Abstract][Full Text] [Related]
19. On-chip isoelectric focusing using photopolymerized immobilized pH gradients.
Sommer GJ; Singh AK; Hatch AV
Anal Chem; 2008 May; 80(9):3327-33. PubMed ID: 18341355
[TBL] [Abstract][Full Text] [Related]
20. Microfluidic high-resolution free-flow isoelectric focusing.
Kohlheyer D; Eijkel JC; Schlautmann S; van den Berg A; Schasfoort RB
Anal Chem; 2007 Nov; 79(21):8190-8. PubMed ID: 17902700
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]