These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

301 related articles for article (PubMed ID: 14747891)

  • 1. Use of D-T-produced fast neutrons for in vivo body composition analysis: a reference method for nutritional assessment in the elderly.
    Kehayias JJ
    Anal Bioanal Chem; 2004 May; 379(2):188-91. PubMed ID: 14747891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo elemental partition analysis using fast neutrons. A tool for testing the efficacy of new clinical interventions.
    Kehayias JJ; Valtueña S; Waitekus AB; Sheahan CA; O'Neill M
    Ann N Y Acad Sci; 2000 May; 904():140-7. PubMed ID: 10865726
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vivo determination of body fat by measuring total body carbon.
    Kehayias JJ; Heymsfield SB; LoMonte AF; Wang J; Pierson RN
    Am J Clin Nutr; 1991 Jun; 53(6):1339-44. PubMed ID: 2035460
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of body fat and lean in the elderly by measuring body carbon and oxygen: validation against hydrodensitometry.
    Kehayias JJ; Zhuang H; Hughes V; Dowling L
    Appl Radiat Isot; 1998; 49(5-6):723-5. PubMed ID: 9569591
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of fast neutrons for measuring muscle.
    Kehayias JJ; Smith DE; Roubenoff R; Savicki M; Zhuang H
    Appl Radiat Isot; 1998; 49(5-6):737-8. PubMed ID: 9569596
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of the associated particle technique for the whole-body measurement of protein, fat and water by 14 MeV neutron activation analysis--a feasibility study.
    Mitra S; Wolff JE; Garrett R; Peters CW
    Phys Med Biol; 1995 Jun; 40(6):1045-55. PubMed ID: 7659729
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A feasibility study of in vivo 14-MeV neutron activation analysis using the associated particle technique.
    Garrett R; Mitra S
    Med Phys; 1991; 18(5):916-20. PubMed ID: 1961154
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The feasibility of measuring total body carbon by counting neutron inelastic scatter gamma rays.
    Kyere K; Oldroyd B; Oxby CB; Burkinshaw L; Ellis RE; Hill GL
    Phys Med Biol; 1982 Jun; 27(6):805-17. PubMed ID: 7111391
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A feasibility study of prompt capture gamma in vivo neutron activation analysis.
    Zamenhof RG; Deutsch OL; Murray BW
    Med Phys; 1979; 6(3):179-92. PubMed ID: 470841
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Calibration of a prototype in vivo total body composition analyser using 14 MeV neutron activation and the associated particle technique.
    Mitra S; Wolff JE; Garrett R
    Appl Radiat Isot; 1998; 49(5-6):537-9. PubMed ID: 9569537
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A five-compartment model of body composition of healthy subjects assessed using in vivo neutron activation analysis.
    Ryde SJ; Birks JL; Morgan WD; Evans CJ; Dutton J
    Eur J Clin Nutr; 1993 Dec; 47(12):863-74. PubMed ID: 8156983
    [TBL] [Abstract][Full Text] [Related]  

  • 12. In vivo measurement of total body carbon using 238Pu/Be neutron sources.
    Sutcliffe JF; Mitra S; Hill GL
    Phys Med Biol; 1990 Aug; 35(8):1089-98. PubMed ID: 2217535
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Whole body measurement of C, N and O using 14 MeV neutrons and the associated particle time-of-flight technique.
    Mitra S; Wolff JE; Garrett R; Peters CW
    Asia Pac J Clin Nutr; 1995 Mar; 4(1):187-9. PubMed ID: 24394280
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Cross-section measurements for (n, 2n) and (n, alpha) reactions on yttrium at neutron energies from 13.5 to 14.6 MeV.
    Zhou F; Zhang H; Huang H; Li K; Yi Y; Tuo F; Kong X
    Appl Radiat Isot; 2008 Dec; 66(12):1898-900. PubMed ID: 18650098
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A proposed three-phase counting system for the in vivo measurement of the major elements using pulsed 14 MeV neutrons.
    Mitra S; Sutcliffe JF; Hill GL
    Biol Trace Elem Res; 1990; 26-27():423-8. PubMed ID: 1704746
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Prompt-gamma neutron activation analysis facility for in vivo body composition studies in small animals.
    Stamatelatos IE; Kasviki K; Green S; Gainey M; Kalef-Ezra J; Beddoe A
    Anal Bioanal Chem; 2004 May; 379(2):192-7. PubMed ID: 14762643
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A theoretical analysis using ratios of the major elements measured by neutron activation analysis to derive total body water, protein, and fat.
    Sutcliffe JF; Smith AH; Barker MC; Smith MA
    Med Phys; 1993; 20(4):1129-34. PubMed ID: 8413022
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The elemental analysis of the human body using associated particle timing based on the D + D reaction.
    Evans CJ; Petö GC; al-Lehyani S; Darko JB
    Appl Radiat Isot; 1998; 49(5-6):549-51. PubMed ID: 9569539
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Neutron activation analysis determination of body composition.
    Kehayias JJ; Valtueña S
    Curr Opin Clin Nutr Metab Care; 1999 Nov; 2(6):453-63. PubMed ID: 10678673
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo simulation of moderator and reflector in coal analyzer based on a D-T neutron generator.
    Shan Q; Chu S; Jia W
    Appl Radiat Isot; 2015 Nov; 105():204-208. PubMed ID: 26325583
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.