These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 1475100)

  • 1. Experience with the cochlear miniature speech processor in adults and children together with a comparison of unipolar and bipolar modes.
    Lehnhardt E; Gnadeberg D; Battmer RD; von Wallenberg E
    ORL J Otorhinolaryngol Relat Spec; 1992; 54(6):308-13. PubMed ID: 1475100
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Correlation between electrically-induced stapedius reflex and discomfort threshold in cochlear implant patients].
    Gattaz G; Battmer RD; Lehnhardt E; Gnadeberg D
    HNO; 1992 Dec; 40(12):480-3. PubMed ID: 1493968
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Effect of anesthesia on the intraoperative elicited stapedius reflex].
    Gnadeberg D; Battmer RD; Lüllwitz E; Laszig R; Dybus U; Lenarz T
    Laryngorhinootologie; 1994 Mar; 73(3):132-5. PubMed ID: 8172632
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Using evoked compound action potentials to assess activation of electrodes and predict C-levels in the Tempo+ cochlear implant speech processor.
    Alvarez I; de la Torre A; Sainz M; Roldán C; Schoesser H; Spitzer P
    Ear Hear; 2010 Feb; 31(1):134-45. PubMed ID: 19838116
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The usefulness of intraoperatively registered, electrically evoked stapedius reflex for the programming of cochlear implants in children].
    Zehnder A; Allum JH; Honegger F; Probst R
    HNO; 1999 Nov; 47(11):970-5. PubMed ID: 10602787
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [How does a cochlear implant speech processor work?].
    Adunka O; Kiefer J
    Laryngorhinootologie; 2005 Nov; 84(11):841-50; quiz 851-4. PubMed ID: 16358193
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrically elicited stapedius reflex in cochlear implant patients.
    Battmer RD; Laszig R; Lehnhardt E
    Ear Hear; 1990 Oct; 11(5):370-4. PubMed ID: 2262087
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Stapedius reflex measurements during surgery for cochlear implantation in children.
    van den Borne B; Snik AF; Mens LH; Brokx JP; van den Broek P
    Am J Otol; 1996 Jul; 17(4):554-8. PubMed ID: 8841700
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Evoked stapedius reflex and compound action potential thresholds versus most comfortable loudness level: assessment of their relation for charge-based fitting strategies in implant users.
    Walkowiak A; Lorens A; Polak M; Kostek B; Skarzynski H; Szkielkowska A; Skarzynski PH
    ORL J Otorhinolaryngol Relat Spec; 2011; 73(4):189-95. PubMed ID: 21659787
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Experiences in Kiel with the cochlear implant].
    Müller-Deile J; Schmidt BJ; Rudert H
    Laryngorhinootologie; 1994 Jun; 73(6):300-10. PubMed ID: 8060448
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Noise signal reduction in cochlear implant speech processors].
    Müller-Deile J
    HNO; 1995 Sep; 43(9):545-51. PubMed ID: 7591867
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing fitting in children using objective measures such as neural response imaging and electrically evoked stapedius reflex threshold.
    Caner G; Olgun L; Gültekin G; Balaban M
    Otol Neurotol; 2007 Aug; 28(5):637-40. PubMed ID: 17667772
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of EEG monitoring on intraoperative stapedius reflex threshold values in cochlear implantation in children.
    Schultz B; Beger FA; Weber BP; Niclaus O; Lüllwitz E; Grouven U; Schultz A
    Paediatr Anaesth; 2003 Nov; 13(9):790-6. PubMed ID: 14617120
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intraoperative electrically elicited stapedius reflex threshold is related to the dosage of hypnotic drugs in general anesthesia.
    Schultz A; Berger FA; Weber BP; Grouven U; Niclaus O; Lüllwitz E; Schultz B
    Ann Otol Rhinol Laryngol; 2003 Dec; 112(12):1050-5. PubMed ID: 14703109
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Effects of preoperative electrical stimulability and historical factors on performance with multichannel cochlear implant.
    Kileny PR; Zimmerman-Phillips S; Kemink JL; Schmaltz SP
    Ann Otol Rhinol Laryngol; 1991 Jul; 100(7):563-8. PubMed ID: 2064268
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Blink reflex and auditory speech perception in prelingually cochlear-implanted children.
    Emamdjomeh H; Shafaghat L; Abbassalipour P; Hassanzadeh S; Alaeddini F; Farhadi M; Daneshi A
    Acta Otolaryngol; 2005 Apr; 125(4):358-62. PubMed ID: 15823805
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digital speech processing for cochlear implants.
    Dillier N; Bögli H; Spillmann T
    ORL J Otorhinolaryngol Relat Spec; 1992; 54(6):299-307. PubMed ID: 1475099
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Intra- and postoperative electrically evoked stapedius reflex thresholds in children with cochlear implants.
    Baysal E; Karatas E; Deniz M; Baglam T; Durucu C; Karatas ZA; Mumbuc S; Kanlikama M
    Int J Pediatr Otorhinolaryngol; 2012 May; 76(5):649-52. PubMed ID: 22342227
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Use of stapedius reflex in cochlear implant of congenitally deaf children.
    Ura M; Owa T; Nong D; Fusato N; Noda Y
    Adv Otorhinolaryngol; 2000; 57():165-7. PubMed ID: 11892137
    [No Abstract]   [Full Text] [Related]  

  • 20. Basic fitting and evaluation parameters of a newly designed cochlear implant electrode.
    Deman PR; Daemers K; Yperman M; Offeciers FE; Plasmans A; Van Dijk B; Govaerts PJ
    Acta Otolaryngol; 2004 Apr; 124(3):281-5. PubMed ID: 15141756
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.