These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

124 related articles for article (PubMed ID: 14753278)

  • 1. Successive determination of copper and iron by a flow injection-catalytic photometric method using a serial flow cell.
    Ohno S; Tanaka M; Teshima N; Sakai T
    Anal Sci; 2004 Jan; 20(1):171-5. PubMed ID: 14753278
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Utilization of activating and masking effects by ligands for highly selective catalytic spectrophotometric determination of copper and iron in natural waters.
    Ohno S; Teshima N; Zhang H; Sakai T
    Talanta; 2003 Aug; 60(6):1177-85. PubMed ID: 18969144
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Catalytic flow-injection determination of sub-ppb copper(II) using the redox reaction of cysteine with iron(III) in the presence of 2,4,6-tris(2-pyridyl)-1,3,5-triazine.
    Wei J; Teshima N; Ohno S; Sakai T
    Anal Sci; 2003 May; 19(5):731-5. PubMed ID: 12769374
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sequential determination of trace amounts of iron and copper in water samples by flow injection analysis with catalytic spectrophotometric detection.
    Lunvongsa S; Tsuboi T; Motomizu S
    Anal Sci; 2006 Jan; 22(1):169-72. PubMed ID: 16429797
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stopped-in-loop flow analysis system for successive determination of trace vanadium and iron in drinking water using their catalytic reactions.
    Ayala Quezada A; Ohara K; Ratanawimarnwong N; Nacapricha D; Murakami H; Teshima N; Sakai T
    Talanta; 2015 Nov; 144():844-50. PubMed ID: 26452899
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Novel catalytic oxidative coupling reaction of N,N-dimethyl-p-phenylenediamine with 1,3-phenylenediamine and its applications to the determination of copper and iron at trace levels by flow injection technique.
    Lunvongsa S; Takayanagi T; Oshima M; Motomizu S
    Anal Chim Acta; 2006 Aug; 576(2):261-9. PubMed ID: 17723641
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Flow-injection determination of copper(II) based on its catalysis on the redox reaction of cysteine with iron(III) in the presence of 1,10-phenanthroline.
    Teshima N; Katsumata H; Kurihara M; Sakai T; Kawashima T
    Talanta; 1999 Aug; 50(1):41-7. PubMed ID: 18967692
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sequential injection lab-on-valve simultaneous spectrophotometric determination of trace amounts of copper and iron.
    Ohno S; Teshima N; Sakai T; Grudpan K; Polasek M
    Talanta; 2006 Jan; 68(3):527-34. PubMed ID: 18970353
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of total and dissolved amount of iron in water samples using catalytic spectrophotometric flow injection analysis.
    Lunvongsa S; Oshima M; Motomizu S
    Talanta; 2006 Jan; 68(3):969-73. PubMed ID: 18970418
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Flow injection determination of iron by its catalytic effect on the oxidation of 3,3',5,5'-tetramethylbenzidine by hydrogen peroxide.
    Tsuji A; Teshima N; Kurihara M; Nakano S; Kawashima T
    Talanta; 2000 May; 52(1):161-7. PubMed ID: 18967973
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A kinetic method for the determination of copper(II) by its catalytic effect on the oxidation of 3-methyl-2-benzothiazolinone hydrazone with hydrogen peroxide: a mechanistic study.
    Tomiyasu T; Aikou S; Anazawa K; Sakamoto H
    Anal Sci; 2005 Aug; 21(8):917-22. PubMed ID: 16122161
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ion paired chromatography of iron (II,III), nickel (II) and copper (II) as their 4,7-Diphenyl-1,10-phenanthroline chelates.
    Mudasir ; Yoshioka N; Inoue H
    Talanta; 1997 Jul; 44(7):1195-202. PubMed ID: 18966854
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Catalytic flow-injection determination of copper at nanogram levels by using color formation of N-phenyl-p-phenylenediamine with m-phenylenediamine in the presence of pyridine and ammonia as activators.
    Nakano S; Nakaso K; Noguchi K; Kawashima T
    Talanta; 1997 May; 44(5):765-70. PubMed ID: 18966799
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reverse flow injection analysis method for catalytic spectrophotometric determination of iron in estuarine and coastal waters: a comparison with normal flow injection analysis.
    Huang Y; Yuan D; Dai M; Liu Y
    Talanta; 2012 May; 93():86-93. PubMed ID: 22483881
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Flow-injection photometric determination of nanogram levels of iron based on the catalysis of oxidative coupling of N-phenyl-p-phenylenediamine with m-phenylenediamine in a micellar medium.
    Nakano S; Tsujii K; Kawashima T
    Talanta; 1995 Aug; 42(8):1051-6. PubMed ID: 18966328
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Catalytic flow-injection determination of reactive iron in non-acidified water samples.
    Kawakubo S; Okazaki Y; Iwatsuki M
    Anal Sci; 2003 Mar; 19(3):373-8. PubMed ID: 12675342
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flow injection analysis for oxidation state speciation of vanadium(IV) and vanadium(V) in natural water.
    Wei J; Teshima N; Sakai T
    Anal Sci; 2008 Mar; 24(3):371-6. PubMed ID: 18332545
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensitive flow injection colorimetry of nitrite by catalytic coupling of N-phenyl-p-phenylenediamine with N,N-dimethylaniline.
    Kadowaki R; Nakano S; Kawashima T
    Talanta; 1999 Jan; 48(1):103-7. PubMed ID: 18967448
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Simultaneous determination of copper and iron by flow-injection catalytic kinetic spectrophotometry with multi-channel detector].
    Zhou Y; Li YQ; Yang JG; Zheng B
    Guang Pu Xue Yu Guang Pu Fen Xi; 2003 Apr; 23(2):374-6. PubMed ID: 12961900
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow-injection photometric determination of sub-nanogram amounts of cobalt by its catalysis of the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone with N,N-dimethylaniline in a micellar medium.
    Yu ZY; Teshima N; Nakano S; Kawashima T
    Talanta; 1996 Sep; 43(9):1519-25. PubMed ID: 18966631
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.