These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 14764438)

  • 21. Point: the classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1523-5. PubMed ID: 16825521
    [No Abstract]   [Full Text] [Related]  

  • 22. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Permutt S
    J Appl Physiol (1985); 2006 Nov; 101(5):1528. PubMed ID: 17094182
    [No Abstract]   [Full Text] [Related]  

  • 23. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Brengelmann GL
    J Appl Physiol (1985); 2006 Nov; 101(5):1532. PubMed ID: 17043333
    [No Abstract]   [Full Text] [Related]  

  • 24. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Magder S
    J Appl Physiol (1985); 2006 Nov; 101(5):1533. PubMed ID: 16931558
    [No Abstract]   [Full Text] [Related]  

  • 25. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Wang LY; Wang WK
    J Appl Physiol (1985); 2006 Nov; 101(5):1528-9. PubMed ID: 17094183
    [No Abstract]   [Full Text] [Related]  

  • 26. The classical Guyton view that mean systemic pressure, right atrial pressure, and venous resistance govern venous return is/is not correct.
    Baker RD
    J Appl Physiol (1985); 2006 Nov; 101(5):1529. PubMed ID: 17094184
    [No Abstract]   [Full Text] [Related]  

  • 27. Automated drug delivery system to control systemic arterial pressure, cardiac output, and left heart filling pressure in acute decompensated heart failure.
    Uemura K; Kamiya A; Hidaka I; Kawada T; Shimizu S; Shishido T; Yoshizawa M; Sugimachi M; Sunagawa K
    J Appl Physiol (1985); 2006 Apr; 100(4):1278-86. PubMed ID: 16373447
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Venous return and mean systemic filling pressure: physiology and clinical applications.
    Persichini R; Lai C; Teboul JL; Adda I; Guérin L; Monnet X
    Crit Care; 2022 May; 26(1):150. PubMed ID: 35610620
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical review: Guyton--the role of mean circulatory filling pressure and right atrial pressure in controlling cardiac output.
    Henderson WR; Griesdale DE; Walley KR; Sheel AW
    Crit Care; 2010; 14(6):243. PubMed ID: 21144008
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The effects of phentolamine and nitroglycerin on right-sided hemodynamics in cardiac patients can be explained by a shift of the systemic venous return curve and right-ventricular output curve.
    Imai Y; Ito H; Minatoguchi S; Asano K; Watanabe H; Iguchi H; Koshiji M; Kakami M; Hirakawa S
    Jpn Circ J; 1992 Aug; 56(8):801-14. PubMed ID: 1356164
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of periodic obstructive apneas on venous return in closed-chest dogs.
    Tarasiuk A; Scharf SM
    Am Rev Respir Dis; 1993 Aug; 148(2):323-9. PubMed ID: 8342894
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Effect of PEEP, blood volume, and inspiratory hold maneuvers on venous return.
    Berger D; Moller PW; Weber A; Bloch A; Bloechlinger S; Haenggi M; Sondergaard S; Jakob SM; Magder S; Takala J
    Am J Physiol Heart Circ Physiol; 2016 Sep; 311(3):H794-806. PubMed ID: 27422991
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Right atrial pressure: determinant or result of change in venous return?
    Bendjelid K
    Chest; 2005 Nov; 128(5):3639-40. PubMed ID: 16304325
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Incorporation of venous resistance in Togawa's four quadrant diagram for Guyton's circulatory equilibrium.
    Suga H
    Jpn Heart J; 1988 Jan; 29(1):89-98. PubMed ID: 3398246
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Relationship of left atrial pressure and pulmonary venous flow velocities: importance of baseline mitral and pulmonary venous flow velocity patterns studied in lightly sedated dogs.
    Appleton CP; Gonzalez MS; Basnight MA
    J Am Soc Echocardiogr; 1994; 7(3 Pt 1):264-75. PubMed ID: 8060643
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Assessment of right atrial (RA) and right ventricular (RV) function by gated blood pool scan with krypton-81m: RA and RV pressure-volume loops with simultaneous pressure data.
    Ishiguro M; Hirano T; Watanabe S; Matsuo H; Goto A; Arakawa M
    Adv Ther; 1991; 8(5):235-42. PubMed ID: 10149185
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Assisted circulation without systemic heparinization.
    Weiss BM; von Segesser LK; Turina MI; Vetter W; Seifert B; Pasch T
    J Cardiothorac Vasc Anesth; 1994 Apr; 8(2):168-74. PubMed ID: 8204809
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Volume and its relationship to cardiac output and venous return.
    Magder S
    Crit Care; 2016 Sep; 20(1):271. PubMed ID: 27613307
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Direct recording of cardiac output- and venous return-curves in the dog heart-lung preparation for a graphical analysis of the effects of cardioactive drugs.
    Ishikawa N; Taki K; Hojo Y; Hagino Y; Shigei T
    Jpn Heart J; 1978 Sep; 19(5):775-82. PubMed ID: 731938
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Venous return in systemic haemodynamics].
    Samoĭlenko AV
    Ross Fiziol Zh Im I M Sechenova; 2011 Jan; 97(1):3-23. PubMed ID: 21516746
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.