These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 1477269)

  • 1. [Physical mechanisms of solid-protein interactions in the interface between amorphous silicon carbide and fibrinogen].
    Bolz A; Schaldach M
    Biomed Tech (Berl); 1992 Nov; 37(11):244-53. PubMed ID: 1477269
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Haemocompatibility optimisation of implants by hybrid structuring.
    Bolz A; Schaldach M
    Med Biol Eng Comput; 1993 Jul; 31 Suppl():S123-30. PubMed ID: 8231315
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differences of platelet adhesion and thrombus activation on amorphous silicon carbide, magnesium alloy, stainless steel, and cobalt chromium stent surfaces.
    Hansi C; Arab A; Rzany A; Ahrens I; Bode C; Hehrlein C
    Catheter Cardiovasc Interv; 2009 Mar; 73(4):488-96. PubMed ID: 19235237
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Artificial heart valves: improved blood compatibility by PECVD a-SiC:H coating.
    Bolz A; Schaldach M
    Artif Organs; 1990 Aug; 14(4):260-9. PubMed ID: 2396923
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [In vitro studies of the blood compatibility of amorphous silicon carbide].
    Bolz A; Schaldach M; Schricker KT
    Biomed Tech (Berl); 1990; 35 Suppl 3():25-7. PubMed ID: 2078718
    [No Abstract]   [Full Text] [Related]  

  • 6. Cytocompatibility of two coating materials, amorphous alumina and silicon carbide, using human differentiated cell cultures.
    Naji A; Harmand MF
    Biomaterials; 1991 Sep; 12(7):690-4. PubMed ID: 1742414
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [The electrochemical corrosion behavior of antithrombogenic coatings of amorphous silicon carbide].
    Bolz A; Brem B; Schaldach M
    Biomed Tech (Berl); 1990; 35 Suppl 3():21-4. PubMed ID: 2078700
    [No Abstract]   [Full Text] [Related]  

  • 8. Biocompatibility of silicon carbide in colony formation test in vitro. A promising new ceramic THR implant coating material.
    Santavirta S; Takagi M; Nordsletten L; Anttila A; Lappalainen R; Konttinen YT
    Arch Orthop Trauma Surg; 1998; 118(1-2):89-91. PubMed ID: 9833115
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Toxicity of particulate silicon carbide for macrophages, fibroblasts and osteoblast-like cells in vitro.
    Allen M; Butter R; Chandra L; Lettington A; Rushton N
    Biomed Mater Eng; 1995; 5(3):151-9. PubMed ID: 8555965
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Haemocompatibility evaluation of DLC- and SiC-coated surfaces.
    Nurdin N; François P; Mugnier Y; Krumeich J; Moret M; Aronsson BO; Descouts P
    Eur Cell Mater; 2003 Jun; 5():17-26; discussion 26-8. PubMed ID: 14562274
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Controlled surface chemistry of diamond/β-SiC composite films for preferential protein adsorption.
    Wang T; Handschuh-Wang S; Yang Y; Zhuang H; Schlemper C; Wesner D; Schönherr H; Zhang W; Jiang X
    Langmuir; 2014 Feb; 30(4):1089-99. PubMed ID: 24410163
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Enhanced osteoporotic effect of silicon carbide nanoparticles combine with nano-hydroxyapatite coated anodized titanium implant on healthy bone regeneration in femoral fracture.
    Li T; Li XL; Hu SX; Wu J
    J Photochem Photobiol B; 2019 Aug; 197():111515. PubMed ID: 31255939
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of oxidation on intrinsic residual stress in amorphous silicon carbide films.
    Deku F; Mohammed S; Joshi-Imre A; Maeng J; Danda V; Gardner TJ; Cogan SF
    J Biomed Mater Res B Appl Biomater; 2019 Jul; 107(5):1654-1661. PubMed ID: 30321479
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bioactivation of biomorphous silicon carbide bone implants.
    Will J; Hoppe A; Müller FA; Raya CT; Fernández JM; Greil P
    Acta Biomater; 2010 Dec; 6(12):4488-94. PubMed ID: 20615484
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparative experimental investigation in monkeys between three different implant materials.
    Nordlund A; Zetterqvist L; Odén A
    Int J Oral Maxillofac Surg; 1989 Dec; 18(6):373-7. PubMed ID: 2516106
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single-crystal cubic silicon carbide: an in vivo biocompatible semiconductor for brain machine interface devices.
    Frewin CL; Locke C; Saddow SE; Weeber EJ
    Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2957-60. PubMed ID: 22254961
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SiC protective coating for photovoltaic retinal prosthesis.
    Lei X; Kane S; Cogan S; Lorach H; Galambos L; Huie P; Mathieson K; Kamins T; Harris J; Palanker D
    J Neural Eng; 2016 Aug; 13(4):046016. PubMed ID: 27323882
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plasma-enhanced chemical vapor deposited silicon carbide as an implantable dielectric coating.
    Cogan SF; Edell DJ; Guzelian AA; Ping Liu Y; Edell R
    J Biomed Mater Res A; 2003 Dec; 67(3):856-67. PubMed ID: 14613234
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biocompatibility and wettability of crystalline SiC and Si surfaces.
    Coletti C; Jaroszeski MJ; Pallaoro A; Hoff AM; Iannotta S; Saddow SE
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():5850-3. PubMed ID: 18003344
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Silicon carbide: a versatile material for biosensor applications.
    Oliveros A; Guiseppi-Elie A; Saddow SE
    Biomed Microdevices; 2013 Apr; 15(2):353-68. PubMed ID: 23319268
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.