These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

105 related articles for article (PubMed ID: 1484235)

  • 1. [Development of synthetic bone models for the evaluation of fracture fixation devices].
    Uta S
    Nihon Seikeigeka Gakkai Zasshi; 1992 Nov; 66(11):1156-64. PubMed ID: 1484235
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of a customized artificial osteoporotic bone model of the distal femur.
    Wähnert D; Hoffmeier KL; Stolarczyk Y; Fröber R; Hofmann GO; Mückley T
    J Biomater Appl; 2011 Nov; 26(4):451-64. PubMed ID: 20511385
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fixation of the femoral condyles: a mechanical comparison of small and large fragment screw fixation.
    Khalafi A; Hazelwood S; Curtiss S; Wolinsky P
    J Trauma; 2008 Mar; 64(3):740-4. PubMed ID: 18332817
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Stress analysis of pertrochanteric fractures with different fixation devices--behavior under muscle forces and vertical static loading.
    Sumida M
    Nihon Seikeigeka Gakkai Zasshi; 1983 Apr; 57(4):385-95. PubMed ID: 6875354
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Mechanical properties of bone fixation devices prepared from a human allogenic bone.
    Gut G; Sladowski D
    Transplant Proc; 2007 Nov; 39(9):2920-2. PubMed ID: 18022017
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs.
    Papini M; Zdero R; Schemitsch EH; Zalzal P
    J Biomech Eng; 2007 Feb; 129(1):12-9. PubMed ID: 17227093
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Internal fixation of supracondylar fractures of the femur using bone plates].
    Nagano K
    Nihon Seikeigeka Gakkai Zasshi; 1972 Jan; 46(1):1-23. PubMed ID: 5063441
    [No Abstract]   [Full Text] [Related]  

  • 8. The effect of rigidity on fracture healing in external fixation.
    Chao EY; Aro HT; Lewallen DG; Kelly PJ
    Clin Orthop Relat Res; 1989 Apr; (241):24-35. PubMed ID: 2647334
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Supracondylar femur fracture fixation: mechanical comparison of the 95 degrees condylar side plate and screw versus 95 degrees angled blade plate.
    Jaakkola JI; Lundy DW; Moore T; Jones B; Ganey TM; Hutton WC
    Acta Orthop Scand; 2002 Jan; 73(1):72-6. PubMed ID: 11928916
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical evaluation of Le Fort I maxillary fracture plating techniques.
    Wang H; Chen MS; Fan YB; Tang W; Tian WD
    J Oral Maxillofac Surg; 2007 Jun; 65(6):1109-16. PubMed ID: 17517293
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Antegrade versus retrograde titanium elastic nail fixation of pediatric distal-third femoral-shaft fractures: a mechanical study.
    Mehlman CT; Nemeth NM; Glos DL
    J Orthop Trauma; 2006 Oct; 20(9):608-12. PubMed ID: 17088662
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Primary internal fixation of open fractures: a retrospective study of the use of metallic internal fixation in fresh open fractures.
    Ketenjian AY; Shelton ML
    J Trauma; 1972 Sep; 12(9):756-63. PubMed ID: 5073398
    [No Abstract]   [Full Text] [Related]  

  • 13. [The efficacy of the surgical treatment of condylar fractures of the femur and tibia using traditional methods].
    Shelukhin NI; Polianskiĭ VP
    Vestn Khir Im I I Grek; 1994; 152(3-4):39-41. PubMed ID: 7709529
    [No Abstract]   [Full Text] [Related]  

  • 14. [Development of bone screws].
    Biehl G
    Z Orthop Ihre Grenzgeb; 1972 Dec; 110(6):886-93. PubMed ID: 4264949
    [No Abstract]   [Full Text] [Related]  

  • 15. Fractures about the hip. 3. Massie nail fixation contrasted with Austin Moore replacement in fresh intracapsular fractures.
    Greer RB; Niemann KM
    Geriatrics; 1971 Nov; 26(11):86-92. PubMed ID: 5118173
    [No Abstract]   [Full Text] [Related]  

  • 16. Performance evaluation of a cement-augmented intramedullary fixation system for pathologic lesions of the femoral shaft.
    Miller GJ; Vander Griend RA; Blake WP; Springfield DS
    Clin Orthop Relat Res; 1987 Aug; (221):246-54. PubMed ID: 3608306
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [The mechanical properties of devices used for the fixation of femoral neck fractures (author's transl)].
    Kempf I; Jaeger JH; Freund J; Renault D; Bitar S; Konsbruck R; Butel J; Faure C; Bonnel F
    Rev Chir Orthop Reparatrice Appar Mot; 1981; 67(1):59-69. PubMed ID: 6453396
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Construct stiffness of different fixation methods for supracondylar femoral fractures above total knee prostheses.
    Cusick RP; Lucas GL; McQueen DA; Graber CD
    Am J Orthop (Belle Mead NJ); 2000 Sep; 29(9):695-9. PubMed ID: 11008866
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Possibilities of application of the fixateur externe at the femur - indications, results (author's transl)].
    Hofmann G; Probst J
    Aktuelle Traumatol; 1982 Apr; 12(2):62-8. PubMed ID: 6123230
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An in vitro evaluation of rigid internal fixation techniques for sagittal split ramus osteotomies: advancement surgery.
    Brasileiro BF; Grempel RG; Ambrosano GM; Passeri LA
    J Oral Maxillofac Surg; 2009 Apr; 67(4):809-17. PubMed ID: 19304039
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.