  • 1. Resistance to gas flow in heat and moisture exchangers.
    Wilkes AR
    Anaesthesia; 1992 Dec; 47(12):1095-6. PubMed ID: 1489046
    [No Abstract]   [Full Text] [Related]  

  • 2. The Humidity in a Low-Flow Dräger Fabius Anesthesia Workstation with or without Thermal Insulation or a Heat and Moisture Exchanger: A Prospective Randomized Clinical Trial.
    de Oliveira SA; Lucio LM; Modolo NS; Hayashi Y; Braz MG; de Carvalho LR; Braz LG; Braz JR
    PLoS One; 2017; 12(1):e0170723. PubMed ID: 28129353
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heat and moisture exchanger: importance of humidification in anaesthesia and ventilatory breathing system.
    Parmar V
    J Indian Med Assoc; 2008 Aug; 106(8):533-5, 537. PubMed ID: 18975515
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 2 - practical use, including problems, and their use with paediatric patients.
    Wilkes AR
    Anaesthesia; 2011 Jan; 66(1):40-51. PubMed ID: 21118189
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Comparison of 2 exchangers of heat and humidity in anesthesia (Hygrobac vs Ultipor BB50)].
    Zamaro G; Romano E; Molassi M
    Minerva Anestesiol; 1989 Sep; 55(9):363-5. PubMed ID: 2633085
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Heat and moisture exchangers and breathing filters.
    Hedley RM; Allt-Graham J
    Br J Anaesth; 1994 Aug; 73(2):227-36. PubMed ID: 7917741
    [No Abstract]   [Full Text] [Related]  

  • 7. Complications related to the use of a heat and moisture exchanger.
    Prasad KK; Chen L
    Anesthesiology; 1990 May; 72(5):958. PubMed ID: 2339817
    [No Abstract]   [Full Text] [Related]  

  • 8. The Ohmeda Rascal II. A new gas analyser for anaesthetic use.
    Lockwood GG; Landon MJ; Chakrabarti MK; Whitwam JG
    Anaesthesia; 1994 Jan; 49(1):44-53. PubMed ID: 8311213
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A dangerous defect in a heat and moisture exchanger.
    Prados W
    Anesthesiology; 1989 Nov; 71(5):804. PubMed ID: 2817482
    [No Abstract]   [Full Text] [Related]  

  • 10. Critical incident involving a heat and moisture exchanger with attached flexible connector.
    Mansor M; Chan L
    Anaesth Intensive Care; 1999 Feb; 27(1):114-5. PubMed ID: 10050234
    [No Abstract]   [Full Text] [Related]  

  • 11. Do passive heat and moisture exchangers keep the patient warm?
    Haslam KR; Nielsen CH
    Anesthesiology; 1986 Mar; 64(3):379-81. PubMed ID: 3456733
    [No Abstract]   [Full Text] [Related]  

  • 12. [Changes in ventilation during use of heat and humidity exchangers].
    Croci M; Corrado F; Sibilla E; Tiby A; Vercesi G; Proietti D; Vannucci A
    Minerva Anestesiol; 1991; 57(1-2):13-6. PubMed ID: 2057084
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Heat and moisture exchangers in artificial ventilation. An experimental study of the effect of gas leakage.
    Tilling SE; Hayes B
    Br J Anaesth; 1987 Sep; 59(9):1181-8. PubMed ID: 3663440
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The humidification of anaesthetic gases: its importance and control.
    Chalon J; Ali M; Ramanathan S; Turndorf H
    Can Anaesth Soc J; 1979 Sep; 26(5):361-6. PubMed ID: 385117
    [No Abstract]   [Full Text] [Related]  

  • 15. Heat and moisture exchangers and breathing system filters: their use in anaesthesia and intensive care. Part 1 - history, principles and efficiency.
    Wilkes AR
    Anaesthesia; 2011 Jan; 66(1):31-9. PubMed ID: 21106035
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [The temperature-humidity profile of the PhysioFlex. Studies on a model].
    Wissing H; Kuhn I; Kessler P
    Anaesthesist; 1997 Mar; 46(3):201-6. PubMed ID: 9163264
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Assessment of a hygroscopic heat and moisture exchanger for paediatric use.
    Wilkinson KA; Cranston A; Hatch DJ; Fletcher ME
    Anaesthesia; 1991 Apr; 46(4):296-9. PubMed ID: 2024750
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Leaks from breathing system gas sampling points fitted with Luer connections.
    Smith PJ; Greenbaum R
    Anaesthesia; 1997 Jul; 52(7):707-8. PubMed ID: 9244036
    [No Abstract]   [Full Text] [Related]  

  • 19. [Measurement of flow-resistive work of heat and moisture exchangers during simulated active breathing].
    Nishimura M; Takezawa J; Imanaka H; Taenaka N; Yoshiya I
    Masui; 1990 Jun; 39(6):695-700. PubMed ID: 2388387
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Removal of excess gas from anesthetic circuits].
    Jorgensen S
    Ugeskr Laeger; 1975 May; 137(19):1045-7. PubMed ID: 1135985
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]