These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

193 related articles for article (PubMed ID: 149071)

  • 1. [Complications due to migration of a Kirschner wire from the clavicle (author's transl)].
    Grauthoff H; Klammer HL
    Rofo; 1978 May; 128(5):591-4. PubMed ID: 149071
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Migration of Kirschner pin from clavicle into ascending aorta.
    Nordback I; Markkula H
    Acta Chir Scand; 1985; 151(2):177-9. PubMed ID: 3890437
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transmediastinal migration of Kirschner wire.
    Marchi E; Reis MP; Carvalho MV
    Interact Cardiovasc Thorac Surg; 2008 Oct; 7(5):869-70. PubMed ID: 18658165
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Migration of Kirschner's wire after osteosyntheses (author's transl)].
    Starke W; Schilling H
    Aktuelle Traumatol; 1981 Aug; 11(4):126-9. PubMed ID: 6118018
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Migration of a Kirschner wire from the clavicle into the intrathoracic trachea.
    Nakayama M; Gika M; Fukuda H; Yamahata T; Aoki K; Shiba S; Eguchi K
    Ann Thorac Surg; 2009 Aug; 88(2):653-4. PubMed ID: 19632433
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Case report of the migration of a Kirschner wire into the lungs].
    Pafko P; Franĕk J
    Rozhl Chir; 1988 Apr; 67(4):276-8. PubMed ID: 3293239
    [No Abstract]   [Full Text] [Related]  

  • 7. [Migration of a fragment of a metal pin after osteosynthesis of the right clavicle].
    Stupachenko ON
    Ortop Travmatol Protez; 1981 Nov; (11):35-6. PubMed ID: 7033870
    [No Abstract]   [Full Text] [Related]  

  • 8. [Kirschner wire migration in the contralateral lung after osteosynthesis of a clavicular fracture].
    Hegemann S; Kleining R; Schindler HG; Holthusen H
    Unfallchirurg; 2005 Nov; 108(11):991-3. PubMed ID: 15988570
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Injury of the pulmonary artery, aorta and superior vena cava by a migrating Kirschner's needle].
    Khlyzov VI; Idov EM
    Vestn Khir Im I I Grek; 1983 Jul; 131(7):131-2. PubMed ID: 6353739
    [No Abstract]   [Full Text] [Related]  

  • 10. Kirschner wire migration causing spinal cord injury one year after internal fixation of a clavicle fracture.
    Fransen P; Bourgeois S; Rommens J
    Acta Orthop Belg; 2007 Jun; 73(3):390-2. PubMed ID: 17715732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. [Unusual migration of K-wire following fixation of clavicle fracture: a case report].
    Bezer M; Aydin N; Erol B; Laçin T; Güven O
    Ulus Travma Acil Cerrahi Derg; 2009 May; 15(3):298-300. PubMed ID: 19562556
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Transthoracic migration of a Kirschner wire from the humerus to the abdomen.
    Julià D; Baldó X; Gómez N; Mármol E
    Eur J Cardiothorac Surg; 2012 May; 41(5):1197-8. PubMed ID: 22219432
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Clavicle Kirschner Wire Migration into Left Lung: A Case Report.
    Reghine ÉL; Cirino CCI; Neto AA; Varallo FR; Évora PRB; de Nadai TR
    Am J Case Rep; 2018 Mar; 19():325-328. PubMed ID: 29559613
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Intratracheal migration of two Kirschner wires after surgery for a clavicle fracture.
    Harmouchi H; Bouazzaoui AE; Bensalah A; Badr A; Lakranbi M; Ouadnouni Y; Bouarhroum A; Smahi M
    Asian Cardiovasc Thorac Ann; 2021 Jun; 29(5):428-430. PubMed ID: 33412892
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intrathoracic migration of a Kirschner wire.
    Fuster S; Palliso F; Combalia A; Sanjuan A; Garcia S
    Injury; 1990 Mar; 21(2):124-6. PubMed ID: 2190934
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Thoracoscopic Excision of Migrated Kirschner Wire to Right Pulmonary Hilum.
    Cortés-Julián G; Mier JM; Briseño C
    Ann Thorac Surg; 2015 Oct; 100(4):1461-3. PubMed ID: 26434449
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Trans-mediastinal Kirschner wire migration treated by video-assisted thoracoscopy.
    Cabañero A; Ovejero P; Gorospe L; Serranol P; Muñoz G; Moreno N
    Asian Cardiovasc Thorac Ann; 2018 Jul; 26(6):482-484. PubMed ID: 29923740
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Migration of Kirschner wires following fixation of the clavicle--a report of 2 cases.
    Leppilahti J; Jalovaara P
    Acta Orthop Scand; 1999 Oct; 70(5):517-9. PubMed ID: 10622489
    [No Abstract]   [Full Text] [Related]  

  • 19. Migration of a Broken Kirschner Wire from Lateral End of Clavicle to the Cervical Spine.
    Tamrakar R; Chapagain D
    J Nepal Health Res Counc; 2020 Sep; 18(2):327-329. PubMed ID: 32969404
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraspinal migration of a Kirschner wire 3 months after clavicular fracture fixation.
    Regel JP; Pospiech J; Aalders TA; Ruchholtz S
    Neurosurg Rev; 2002 Mar; 25(1-2):110-2. PubMed ID: 11954764
    [TBL] [Abstract][Full Text] [Related]  