These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

818 related articles for article (PubMed ID: 14982345)

  • 1. Prediction of scratch resistance of cobalt chromium alloy bearing surface, articulating against ultra-high molecular weight polyethylene, due to third-body wear particles.
    Mirghany M; Jin ZM
    Proc Inst Mech Eng H; 2004; 218(1):41-50. PubMed ID: 14982345
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Abrasive wear of ceramic, metal, and UHMWPE bearing surfaces from third-body bone, PMMA bone cement, and titanium debris.
    Davidson JA; Poggie RA; Mishra AK
    Biomed Mater Eng; 1994; 4(3):213-29. PubMed ID: 7950870
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Microscopic asperity contact and deformation of ultrahigh molecular weight polyethylene bearing surfaces.
    Wang FC; Jin ZM; McEwen HM; Fisher J
    Proc Inst Mech Eng H; 2003; 217(6):477-90. PubMed ID: 14702985
    [TBL] [Abstract][Full Text] [Related]  

  • 4. An in vitro study of the reduction in wear of metal-on-metal hip prostheses using surface-engineered femoral heads.
    Fisher J; Hu XQ; Tipper JL; Stewart TD; Williams S; Stone MH; Davies C; Hatto P; Bolton J; Riley M; Hardaker C; Isaac GH; Berry G; Ingham E
    Proc Inst Mech Eng H; 2002; 216(4):219-30. PubMed ID: 12206518
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.
    Zietz C; Bergschmidt P; Lange R; Mittelmeier W; Bader R
    Int J Artif Organs; 2013 Jan; 36(1):47-55. PubMed ID: 23335379
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A simple fully integrated contact-coupled wear prediction for ultra-high molecular weight polyethylene hip implants.
    Kang L; Galvin AL; Jin ZM; Fisher J
    Proc Inst Mech Eng H; 2006 Jan; 220(1):33-46. PubMed ID: 16459444
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.
    Goldsmith AA; Dowson D; Isaac GH; Lancaster JG
    Proc Inst Mech Eng H; 2000; 214(1):39-47. PubMed ID: 10718049
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contact mechanics of metal-on-metal hip implants employing a metallic cup with a UHMWPE backing.
    Liu F; Jin ZM; Grigoris P; Hirt F; Rieker C
    Proc Inst Mech Eng H; 2003; 217(3):207-13. PubMed ID: 12807161
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The predictive power of surface profile parameters on the amount of wear measured in vitro on metal-on-polyethylene artificial hip joints.
    Affatato S; Bersaglia G; Junqiang Y; Traina F; Toni A; Viceconti M
    Proc Inst Mech Eng H; 2006 Apr; 220(3):457-64. PubMed ID: 16808078
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Wear and deformation of ceramic-on-polyethylene total hip replacements with joint laxity and swing phase microseparation.
    Williams S; Butterfield M; Stewart T; Ingham E; Stone M; Fisher J
    Proc Inst Mech Eng H; 2003; 217(2):147-53. PubMed ID: 12666782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Third-body wear of cobalt-chromium-molybdenum implant alloys initiated by bone and poly(methyl methacrylate) particles.
    Que L; Topoleski LD
    J Biomed Mater Res; 2000 Jun; 50(3):322-30. PubMed ID: 10737873
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Surface roughness of retrieved CoCrMo alloy femoral components from PCA artificial total knee joints.
    Que L; Topoleski LD; Parks NL
    J Biomed Mater Res; 2000; 53(1):111-8. PubMed ID: 10634960
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Abrasion resistance of oxidized zirconium in comparison with CoCrMo and titanium nitride coatings for artificial knee joints.
    Galetz MC; Fleischmann EW; Konrad CH; Schuetz A; Glatzel U
    J Biomed Mater Res B Appl Biomater; 2010 Apr; 93(1):244-51. PubMed ID: 20162723
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Five million wear simulation and particle analysis of carbon-based nano-multilayer coatings titanium alloy femoral head].
    Wang HR; Li J; Li ZL; Tu JP; Jin G; Su J; Wang JJ
    Zhonghua Yi Xue Za Zhi; 2020 Feb; 100(7):546-551. PubMed ID: 32164109
    [No Abstract]   [Full Text] [Related]  

  • 15. Wear in the prosthetic shoulder: association with design parameters.
    Hopkins AR; Hansen UN; Amis AA; Knight L; Taylor M; Levy O; Copeland SA
    J Biomech Eng; 2007 Apr; 129(2):223-30. PubMed ID: 17408327
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The influence of bone and bone cement debris on counterface roughness in sliding wear tests of ultra-high molecular weight polyethylene on stainless steel.
    Caravia L; Dowson D; Fisher J; Jobbins B
    Proc Inst Mech Eng H; 1990; 204(1):65-70. PubMed ID: 2353995
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Influence of microscopic surface asperities on the wear of ultra-high molecular weight polyethylene in a knee prosthesis.
    Cho CH; Murakami T; Sawae Y
    Proc Inst Mech Eng H; 2010; 224(4):515-29. PubMed ID: 20476500
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elasto-plastic contact analysis of an ultra-high molecular weight polyethylene tibial component based on geometrical measurement from a retrieved knee prosthesis.
    Cho CH; Murakami T; Sawae Y; Sakai N; Miura H; Kawano T; Iwamoto Y
    Proc Inst Mech Eng H; 2004; 218(4):251-9. PubMed ID: 15376727
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The lexicon of polyethylene wear in artificial joints.
    McKellop HA
    Biomaterials; 2007 Dec; 28(34):5049-57. PubMed ID: 17706766
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
    Okazaki Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 41.