120 related articles for article (PubMed ID: 14983130)
1. [Measurement of depth dose distribution using plastic scintillator].
Hashimoto M; Kodama K; Hanada T; Ide T; Tsukahara T; Ishikawa M; Maruyama K
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2003 Nov; 59(11):1424-31. PubMed ID: 14983130
[TBL] [Abstract][Full Text] [Related]
2. Characterizing energy dependence and count rate performance of a dual scintillator fiber-optic detector for computed tomography.
Hoerner MR; Stepusin EJ; Hyer DE; Hintenlang DE
Med Phys; 2015 Mar; 42(3):1268-79. PubMed ID: 25735282
[TBL] [Abstract][Full Text] [Related]
3. Plastic scintillation dosimetry: optimal selection of scintillating fibers and scintillators.
Archambault L; Arsenault J; Gingras L; Beddar AS; Roy R; Beaulieu L
Med Phys; 2005 Jul; 32(7):2271-8. PubMed ID: 16121582
[TBL] [Abstract][Full Text] [Related]
4. Practical use of a plastic scintillator for quality assurance of electron beam therapy.
Yogo K; Tatsuno Y; Tsuneda M; Aono Y; Mochizuki D; Fujisawa Y; Matsushita A; Ishigami M; Ishiyama H; Hayakawa K
Phys Med Biol; 2017 Jun; 62(11):4551-4570. PubMed ID: 28319041
[TBL] [Abstract][Full Text] [Related]
5. Optimization of a multipoint plastic scintillator dosimeter for high dose rate brachytherapy.
Linares Rosales HM; Duguay-Drouin P; Archambault L; Beddar S; Beaulieu L
Med Phys; 2019 May; 46(5):2412-2421. PubMed ID: 30891803
[TBL] [Abstract][Full Text] [Related]
6. Surface preparation and coupling in plastic scintillator dosimetry.
Ayotte G; Archambault L; Gingras L; Lacroix F; Beddar AS; Beaulieu L
Med Phys; 2006 Sep; 33(9):3519-25. PubMed ID: 17022248
[TBL] [Abstract][Full Text] [Related]
7. Technical Note: Out-of-field dose measurement at near surface with plastic scintillator detector.
Bourgouin A; Varfalvy N; Archambault L
J Appl Clin Med Phys; 2016 Sep; 17(5):542-547. PubMed ID: 27685131
[TBL] [Abstract][Full Text] [Related]
8. Preliminary investigations on the determination of three-dimensional dose distributions using scintillator blocks and optical tomography.
Kroll F; Pawelke J; Karsch L
Med Phys; 2013 Aug; 40(8):082104. PubMed ID: 23927341
[TBL] [Abstract][Full Text] [Related]
9. Temperature dependence of BCF plastic scintillation detectors.
Wootton L; Beddar S
Phys Med Biol; 2013 May; 58(9):2955-67. PubMed ID: 23574889
[TBL] [Abstract][Full Text] [Related]
10. Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: a comparison study of calibration procedures and validation in Cerenkov light-dominated situations.
Guillot M; Gingras L; Archambault L; Beddar S; Beaulieu L
Med Phys; 2011 Apr; 38(4):2140-50. PubMed ID: 21626947
[TBL] [Abstract][Full Text] [Related]
11. Application of plastic scintillating fibres to surface dosimetry in megavoltage photon and electron beams: considerations for Cerenkov correction.
Monajemi TT; Ruiz EA
Phys Med Biol; 2018 Sep; 63(18):185003. PubMed ID: 30101759
[TBL] [Abstract][Full Text] [Related]
12. Technical note: Angular dependence in fiber optic dosimetry using YVO
Martínez N; Fernández Y; Machello S; Molina P; Massa J; Santiago M
Med Phys; 2023 Jul; 50(7):4645-4650. PubMed ID: 36971394
[TBL] [Abstract][Full Text] [Related]
13. Energy dependent response of plastic scintillation detectors to photon radiation of low to medium energy.
Ebenau M; Radeck D; Bambynek M; Sommer H; Flühs D; Spaan B; Eichmann M
Med Phys; 2016 Aug; 43(8):4598. PubMed ID: 27487876
[TBL] [Abstract][Full Text] [Related]
14. Measurements of relative depth doses and Cerenkov light using a scintillating fiber-optic dosimeter with Co-60 radiotherapy source.
Jang KW; Yoo WJ; Moon J; Han KT; Park JY; Lee B
Appl Radiat Isot; 2012 Jan; 70(1):274-7. PubMed ID: 21889353
[TBL] [Abstract][Full Text] [Related]
15. PLASTIC SCINTILLATOR FOR RADIATION DOSIMETRY.
Kim Y; Yoo H; Kim C; Lim KT; Moon M; Kim J; Cho G
Radiat Prot Dosimetry; 2016 Sep; 170(1-4):187-90. PubMed ID: 26538616
[TBL] [Abstract][Full Text] [Related]
16. Development of a fibre-optic dosemeter to measure the skin dose and percentage depth dose in the build-up region of therapeutic photon beams.
Kim KA; Yoo WJ; Jang KW; Moon J; Han KT; Jeon D; Park JY; Cha EJ; Lee B
Radiat Prot Dosimetry; 2013 Mar; 153(3):294-9. PubMed ID: 22764176
[TBL] [Abstract][Full Text] [Related]
17. Improvements to an optical scintillator imaging-based tissue dosimetry system.
Tendler II; Bruza P; Jermyn M; Fleury A; Williams BB; Jarvis LA; Pogue BW; Gladstone DJ
J Biomed Opt; 2019 Jul; 24(7):1-6. PubMed ID: 31313537
[TBL] [Abstract][Full Text] [Related]
18. A feasibility study of novel plastic scintillation dosimetry with pulse-counting mode.
Ishikawa M; Bengua G; Sutherland KL; Hiratsuka J; Katoh N; Shimizu S; Aoyama H; Fujita K; Yamazaki R; Horita K; Shirato H
Phys Med Biol; 2009 Apr; 54(7):2079-92. PubMed ID: 19287089
[TBL] [Abstract][Full Text] [Related]
19. Systematic evaluation of photodetector performance for plastic scintillation dosimetry.
Boivin J; Beddar S; Guillemette M; Beaulieu L
Med Phys; 2015 Nov; 42(11):6211-20. PubMed ID: 26520714
[TBL] [Abstract][Full Text] [Related]
20. Clinical prototype of a plastic water-equivalent scintillating fiber dosimeter array for QA applications.
Lacroix F; Archambault L; Gingras L; Guillot M; Beddar AS; Beaulieu L
Med Phys; 2008 Aug; 35(8):3682-90. PubMed ID: 18777928
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]