These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 14984184)

  • 1. Elimination of microbubbles from the extracorporeal circuit: dynamic bubble trap versus arterial filter.
    Martens S; Dietrich M; Pietrzyk R; Graubitz K; Keller H; Moritz A
    Int J Artif Organs; 2004 Jan; 27(1):55-9. PubMed ID: 14984184
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Application of dynamic bubble trap in coronary artery bypass with cardiopulmonary bypass: an initial study].
    Wu M; Chen RK; Cremer J
    Zhonghua Yi Xue Za Zhi; 2004 Dec; 84(23):1986-9. PubMed ID: 15730812
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The dynamic bubble trap reduces microbubbles in extracorporeal circulation and high intensity transient signals in the middle cerebral artery: a case report.
    Perthel M; Kseibi S; Bendisch A; Laas J
    Perfusion; 2003 Sep; 18(5):325-9. PubMed ID: 14604252
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dynamic bubble trap can replace an arterial filter during cardiopulmonary bypass surgery.
    Göritz S; Schelkle H; Rein JG; Urbanek S
    Perfusion; 2006 Nov; 21(6):367-71. PubMed ID: 17312861
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Use of a dynamic bubble trap in the arterial line reduces microbubbles during cardiopulmonary bypass and microembolic signals in the middle cerebral artery.
    Perthel M; Kseibi S; Bendisch A; Laas J
    Perfusion; 2005 May; 20(3):151-6. PubMed ID: 16038387
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A dynamic bubble trap reduces microbubbles during cardiopulmonary bypass: a case study.
    Schönburg M; Urbanek P; Erhardt G; Taborski U; Plechinger H; Hein S; Roth M; Klövekorn WP
    J Extra Corpor Technol; 2000 Sep; 32(3):165-9. PubMed ID: 11146963
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Deairing of the venous drainage in standard extracorporeal circulation results in a profound reduction of arterial micro bubbles.
    Stock UA; Müller T; Bienek R; Krause H; Hartrumpf M; Albes J
    Thorac Cardiovasc Surg; 2006 Feb; 54(1):39-41. PubMed ID: 16485187
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Behavior of gaseous microemboli in extracorporeal circuits: air versus CO2.
    Martens S; Dietrich M; Doss M; Deschka M; Keller H; Moritz A
    Int J Artif Organs; 2006 Jun; 29(6):578-82. PubMed ID: 16841286
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Significant reduction of air microbubbles with the dynamic bubble trap during cardiopulmonary bypass.
    Schönburg M; Urbanek P; Erhardt G; Kraus B; Taborski U; Mühling A; Hein S; Roth M; Tiedtke HJ; Klövekorn WP
    Perfusion; 2001 Jan; 16(1):19-25. PubMed ID: 11192303
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effectiveness of microbubble removal in an airtrap with a free surface interface.
    Keshavarzi G; Simmons A; Yeoh G; Barber T
    J Biomech; 2015 May; 48(7):1237-40. PubMed ID: 25841295
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The dynamic air bubble trap reduces cerebral microembolism during cardiopulmonary bypass.
    Schoenburg M; Kraus B; Muehling A; Taborski U; Hofmann H; Erhardt G; Hein S; Roth M; Vogt PR; Karliczek GF; Kloevekorn WP
    J Thorac Cardiovasc Surg; 2003 Nov; 126(5):1455-60. PubMed ID: 14666019
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reduction of gaseous microembolism during aortic valve replacement using a dynamic bubble trap.
    Schönburg M; Ziegelhoeffer T; Kraus B; Mühling A; Heidt M; Taborski U; Gerriets T; Roth M; Hein S; Urbanek S; Klövekorn WP
    Gen Physiol Biophys; 2006 Jun; 25(2):207-14. PubMed ID: 16917133
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A new minimized perfusion circuit provides highly effective ultrasound controlled deairing.
    Kutschka I; Schönrock U; El Essawi A; Pahari D; Anssar M; Harringer W
    Artif Organs; 2007 Mar; 31(3):215-20. PubMed ID: 17343697
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of conventional extracorporeal circulation and minimal extracorporeal circulation with respect to microbubbles and microembolic signals.
    Perthel M; Kseibi S; Sagebiel F; Alken A; Laas J
    Perfusion; 2005 Oct; 20(6):329-33. PubMed ID: 16363318
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Carbon Dioxide Flush of an Integrated Minimized Perfusion Circuit Prior to Priming Prevents Spontaneous Air Release Into the Arterial Line During Clinical Use.
    Stehouwer MC; de Vroege R; Hoohenkerk GJF; Hofman FN; Kelder JC; Buchner B; de Mol BA; Bruins P
    Artif Organs; 2017 Nov; 41(11):997-1003. PubMed ID: 28741663
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Clinical evaluation of the air removal characteristics of an oxygenator with integrated arterial filter in a minimized extracorporeal circuit.
    Stehouwer MC; Boers C; de Vroege R; C Kelder J; Yilmaz A; Bruins P
    Int J Artif Organs; 2011 Apr; 34(4):374-82. PubMed ID: 21534248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The effectiveness of low-prime cardiopulmonary bypass circuits at removing gaseous emboli.
    Norman MJ; Sistino JJ; Acsell JR
    J Extra Corpor Technol; 2004 Dec; 36(4):336-42. PubMed ID: 15679274
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Influence of venous reservoir level on microbubbles in cardiopulmonary bypass.
    Nielsen PF; Funder JA; Jensen MØ; Nygaard H
    Perfusion; 2008 Nov; 23(6):347-53. PubMed ID: 19454563
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Hemodialysis dialyzers contribute to contamination of air microemboli that bypass the alarm system in the air trap.
    Stegmayr C; Jonsson P; Forsberg U; Stegmayr B
    Int J Artif Organs; 2008 Apr; 31(4):317-22. PubMed ID: 18432587
    [TBL] [Abstract][Full Text] [Related]  

  • 20. In vitro and in vivo evaluation of Dideco's paediatric cardiopulmonary circuit for neonates weighing less than five kilograms.
    Thiara AS; Eggereide V; Pedersen T; Lindberg H; Fiane AE
    Perfusion; 2010 Jul; 25(4):229-35. PubMed ID: 20576728
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.